• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BD08-0AV0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2BD08-0AV0 WinCC flexible 2008

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6381-2BD08-0AV0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BD08-0AV0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI product line and is used to create visualization projects for operator panels across the SIMATIC portfolio.

    WinCC flexible 2008 offers a comprehensive engineering environment with support for a wide range of SIMATIC HMI devices, including Micro Panels, Mobile Panels, Operator Panels (OP), Touch Panels (TP), and Multi Panels. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS, and Ethernet interfaces. It includes features such as recipe management, trend displays, alarm logging, user administration, and multi-language project support. The engineering tool runs on standard Windows-based PCs and provides a project migration path from ProTool and earlier WinCC flexible versions.

    WinCC flexible 2008 is widely used in manufacturing, process automation, and machine building industries where SIMATIC HMI panels are deployed. It is suitable for applications in automotive production lines, packaging machinery, conveyor systems, and general factory automation. The software's broad device compatibility and integration with the SIMATIC controller family make it a standard engineering tool for system integrators and OEMs working within the Siemens automation ecosystem.

    Technical Specifications

    Software Version WinCC flexible 2008
    License Type Single-user engineering license
    Supported HMI Devices SIMATIC Micro Panels, OP, TP, MP, Mobile Panels
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP)
    Operating System Windows XP, Windows Vista, Windows 7 (32-bit)
    Project Migration ProTool, WinCC flexible 2004/2005/2007
    Languages Supported Multi-language project support
    Certifications CE
    Series/Product Family SIMATIC WinCC flexible

    Common Error Codes and System Events

    Event ID: 1000001
    License not found or invalid license key detected during software startup
    Verify that the correct license key is installed using the Automation License Manager. Reinstall or transfer the license if necessary.
    Event ID: 1000002
    Project compilation error due to inconsistent tag or screen configuration
    Review the project consistency check log in the engineering tool, correct all reported errors in tag connections or screen objects, and recompile the project.
    Event ID: 1000003
    Communication driver initialization failure — connection to PLC cannot be established
    Check the communication interface settings (MPI address, PROFIBUS baud rate, or Ethernet IP address), verify cable connections, and confirm the PLC is powered and online.
    Event ID: 1000004
    Runtime transfer error — project download to HMI panel failed
    Ensure the HMI panel is in transfer mode, verify the PC-to-panel connection (USB, Ethernet, or MPI/PROFIBUS), and check that the project is compiled without errors before retransfer.
    Event ID: 1000005
    Insufficient memory on target HMI device for the compiled project
    Reduce the project size by removing unused screens, images, or recipes. Check the memory requirements of the target panel and optimize the project accordingly.
    Event ID: 1000006
    Alarm logging or data logging failure due to storage medium error
    Check the storage medium (internal flash, memory card, or USB) on the HMI panel. Format or replace the storage medium and reconfigure the logging settings in the project.
    Event ID: 1000007
    Screen object update failure — dynamic tag values not refreshing on HMI display
    Verify tag connections in the project, check the PLC communication status, and confirm that the update cycle times configured for the affected tags are appropriate.

    Frequently Asked Questions

    Which SIMATIC HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports a wide range of SIMATIC HMI devices including Micro Panels (KTP series), Operator Panels (OP 77, OP 177, OP 277), Touch Panels (TP 177, TP 277), Multi Panels (MP 277, MP 377), and Mobile Panels (177, 277).

    Can WinCC flexible 2008 projects be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that allows WinCC flexible 2008 projects to be imported and converted for use with WinCC in TIA Portal, though some manual rework may be required depending on project complexity.

    What operating systems are compatible with WinCC flexible 2008?

    WinCC flexible 2008 is compatible with Windows XP (SP3), Windows Vista, and Windows 7 (32-bit editions). It is not natively supported on 64-bit operating systems without compatibility configuration.

    Does WinCC flexible 2008 support communication with S7-1200 PLCs?

    Yes, with the appropriate service pack updates applied, WinCC flexible 2008 supports communication with SIMATIC S7-1200 PLCs via Ethernet using the TCP/IP protocol.

    Is a separate runtime license required to run projects on HMI panels?

    The runtime software is embedded in the SIMATIC HMI panel firmware, so a separate PC runtime license is not required for panel-based operation. The 6AV6381-2BD08-0AV0 license covers the engineering (configuration) environment on the PC.

    Troubleshooting

    Software fails to start and displays a license error message

    Open the Siemens Automation License Manager and check whether a valid WinCC flexible 2008 license is present and correctly assigned to the local machine or dongle.

    Transfer or reinstall the license using the Automation License Manager. If using a USB dongle, ensure it is connected before launching the software. Contact Siemens license support if the license key is corrupted.

    Project cannot be transferred to the HMI panel via Ethernet

    Verify the IP address configuration of both the PC and the HMI panel. Check that both devices are on the same subnet and that no firewall is blocking the transfer port.

    Set matching IP addresses and subnet masks on the PC and panel. Disable Windows Firewall temporarily during transfer or add WinCC flexible as a firewall exception. Ensure the panel is set to transfer mode.

    PLC tags are not updating on the HMI screen during runtime

    Check the communication status indicator in the WinCC flexible runtime. Verify the PLC connection parameters (IP address, MPI address, or PROFIBUS address) match the actual PLC configuration.

    Correct the communication parameters in the project and retransfer to the panel. Check physical cable connections and confirm the PLC is in RUN mode. Reduce tag update cycle times if the network is heavily loaded.

    WinCC flexible 2008 installation fails or aborts on Windows 7

    Check the Windows Event Viewer for installation error codes. Confirm that the PC meets the minimum hardware requirements and that no conflicting software or previous WinCC installation remnants are present.

    Run the installer as Administrator, ensure all Windows updates are applied, and remove any previous WinCC flexible installations using the Siemens uninstall tool before attempting a clean installation.

    Compiled project exceeds the memory capacity of the target HMI panel

    Use the WinCC flexible project properties to review the estimated memory usage. Identify large image files, unused screens, or oversized recipe data sets that may be contributing to the excess size.

    Compress or reduce the resolution of imported images, delete unused screens and templates, and limit the number of recipe entries. Verify that the correct target panel model is selected in the project settings.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart