• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
    Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

    Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

    € 1.247,00

    Reset
    Clear
    SKU: 6AV6545-8CC10-0AA0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6545-8CC10-0AA0 is a Mobile Panel 177 belonging to the SIMATIC HMI product family. It is a portable human-machine interface device designed for flexible, handheld operation and monitoring of industrial machinery and processes. This unit provides operators with the ability to move freely around a machine or installation while maintaining full control and visualization capabilities.

    The Mobile Panel 177 features a 5.7-inch STN color display with a resolution of 320 x 240 pixels and touch screen functionality combined with configurable function keys for versatile input options. It connects to controllers via PROFIBUS DP or MPI interfaces, enabling seamless integration with Siemens SIMATIC S7 and other compatible PLC families. The panel includes an integrated enabling button and emergency stop button, which are critical safety features for handheld operation in hazardous machine environments. It operates on 24 V DC supply and is configured using Siemens WinCC flexible engineering software.

    The Mobile Panel 177 is widely used in machine tool, automotive assembly, packaging, and general manufacturing industries where operators need to perform setup, commissioning, or maintenance tasks directly at the machine. Its handheld form factor and integrated safety controls make it particularly suitable for applications requiring close proximity operation, such as robot cell tending, press line setup, and conveyor system maintenance. The robust housing and IP65 protection rating ensure reliable operation in typical industrial shop floor environments.

    Technical Specifications

    Display Size 5.7 inch
    Display Resolution 320 x 240 pixels
    Display Type STN color
    Touch Technology Resistive touchscreen
    Input/Operating Voltage 24 V DC
    Communication Interface PROFIBUS DP / MPI
    IP/Protection Rating IP65
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Safety Features Integrated enabling button, Emergency stop button
    Engineering Software WinCC flexible
    Series/Product Family SIMATIC Mobile Panel 177
    Mounting Handheld / portable
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the Mobile Panel and the connected PLC or controller. The panel cannot establish or maintain a connection via PROFIBUS DP or MPI.
    Check the PROFIBUS/MPI cable connections and termination resistors. Verify the configured station address matches the PLC settings. Ensure the PLC is in RUN mode.
    Event ID: 10001
    Connection to the configured PLC project has been lost during operation.
    Check physical cable integrity and connector seating. Verify network address configuration in WinCC flexible project settings. Restart the panel and attempt reconnection.
    Event ID: 20000
    Project download error. The project file could not be transferred to the Mobile Panel successfully.
    Verify the communication settings in WinCC flexible. Check that the PC and panel are on the same network or correctly connected via MPI/USB. Retry the download after restarting both devices.
    Event ID: 40000
    System memory low. Available memory on the panel is insufficient to load or run the configured project.
    Reduce the project size by optimizing graphics and screen objects. Delete unused projects from the panel memory. Perform a panel reset if necessary.
    Event ID: 50000
    Operating system error or firmware fault detected on the panel.
    Perform a panel reset using the reset button. If the fault persists, re-flash the panel firmware using the ProSave tool and reload the project.
    Enabling Button Fault
    The enabling button signal is not being detected correctly, preventing machine motion commands from being executed.
    Inspect the enabling button mechanism for mechanical damage or contamination. Test the button continuity. If faulty, the handset unit may require repair or replacement.
    Emergency Stop Active
    The integrated emergency stop button on the Mobile Panel has been actuated, placing the connected machine in a safe stop state.
    Identify and resolve the cause of the emergency stop activation. Physically release the emergency stop button by rotating it, then reset the safety circuit at the controller before resuming operation.

    Frequently Asked Questions

    Which engineering software is used to configure the Mobile Panel 177 (6AV6545-8CC10-0AA0)?

    The Mobile Panel 177 is configured using Siemens WinCC flexible software. Projects are created on a PC and then downloaded to the panel via MPI, PROFIBUS, or USB connection.

    Which PLCs are compatible with the Mobile Panel 177?

    The Mobile Panel 177 is primarily designed for use with Siemens SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with other PROFIBUS-compatible controllers.

    Does the 6AV6545-8CC10-0AA0 include integrated safety features?

    Yes, the Mobile Panel 177 includes an integrated enabling button and an emergency stop button. These are hardware safety features required for safe handheld operation near moving machinery.

    What is the display type and size on this Mobile Panel?

    The panel features a 5.7-inch STN color display with a resolution of 320 x 240 pixels, combined with a resistive touchscreen and physical function keys.

    What is the IP protection rating of the Mobile Panel 177?

    The Mobile Panel 177 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for typical industrial shop floor environments.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC supply voltage is present at the power connector. Measure voltage at the panel input terminals. Inspect the supply cable for damage.

    Ensure the 24 V DC power supply is within specification and correctly connected. If voltage is present but the display remains off, the internal power supply board or display backlight may be faulty and the unit should be sent for repair.

    Panel fails to establish communication with the PLC

    Verify the PROFIBUS or MPI cable is correctly connected and terminated. Check the bus address configured on the panel matches the project settings. Use a PROFIBUS diagnostic tool to check bus activity.

    Correct any address conflicts, replace damaged cables, and ensure proper termination resistors are fitted at both ends of the PROFIBUS segment. Re-download the project from WinCC flexible after correcting settings.

    Touchscreen does not respond or responds inaccurately

    Check for physical damage or contamination on the touch surface. Attempt a touchscreen recalibration from the panel's system settings menu.

    Clean the touch surface with a soft, dry cloth. Perform a touchscreen calibration procedure via the Control Panel in the panel's start center. If the issue persists, the touchscreen overlay may require replacement.

    Project download fails or times out

    Verify the communication interface settings in WinCC flexible match the physical connection type (MPI, PROFIBUS, or USB). Check that the panel is in transfer mode before initiating the download.

    Set the panel to transfer mode via the start center, confirm the correct interface and baud rate in WinCC flexible, and retry the download. Ensure no firewall or PC software is blocking the communication port.

    Enabling button not recognized by the safety circuit

    Test the enabling button by pressing it to the first and second detent positions while monitoring the safety relay or controller input signals. Check the cable connecting the panel to the safety interface box for continuity.

    If the enabling button signals are absent, inspect the cable and connector for damage. If the button mechanism is faulty, the handset unit requires professional repair or replacement of the enabling switch assembly.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart