
Siemens 6AV6381-2BD08-0AX0 WinCC flexible 2008
€ 1.995,00
The Siemens 6AV6381-2BD08-0AX0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and deploying human-machine interface (HMI) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create, configure, and manage visualization projects.
WinCC flexible 2008 offers a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and script-based automation. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Ethernet interfaces. It provides multi-language project support, integrated simulation for offline testing, and is compatible with a wide range of Siemens HMI hardware including the TP, OP, MP, and Mobile Panel series.
WinCC flexible 2008 is widely used in manufacturing, process automation, packaging, and machine tool industries where centralized HMI configuration and visualization are required. It is particularly suited for projects involving multiple panel types and distributed HMI architectures. The software enables engineers to standardize visualization across different machine lines and production facilities using a single engineering environment.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| License Type | Single-user engineering license |
| Compatible PLC Families | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces | MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP) |
| Supported HMI Hardware | SIMATIC TP, OP, MP, Mobile Panel series |
| Operating System | Windows XP (SP2 or higher), Windows Vista, Windows 7 |
| Project Languages | Up to 32 languages per project |
| Alarm Management | Integrated alarm logging and archiving |
| Recipe Management | Supported |
| Trend Display | Supported |
| Offline Simulation | Integrated project simulator included |
| Series/Product Family | SIMATIC WinCC flexible 2008 |
Common Error Codes & System Events
- Event ID: 1000001
- License not found or invalid license key detected during startup
Verify the license dongle or software license is correctly installed. Use Siemens Automation License Manager (ALM) to check license status and transfer if necessary. - Event ID: 1000002
- Project version mismatch — project was created with a newer or incompatible version of WinCC flexible
Upgrade the WinCC flexible installation to the required version or migrate the project to the current version using the project migration wizard. - Event ID: 1000010
- Communication error to PLC — connection to the configured SIMATIC controller cannot be established
Check physical network connections, verify PLC address settings in the project, and confirm the correct communication driver is installed and configured. - Event ID: 1000020
- Tag read/write error — a configured tag cannot be read from or written to the PLC
Verify the tag address in the HMI project matches the actual PLC data block or memory area. Check PLC program for address conflicts. - Event ID: 1000030
- Runtime startup failure — WinCC flexible Runtime cannot start the project on the target device
Check available memory on the target HMI device, verify the project was correctly transferred, and confirm the Runtime license is present on the device. - Event ID: 1000040
- Transfer error — project transfer to HMI panel failed or was interrupted
Check the transfer cable or network connection between the engineering PC and the HMI panel. Ensure the panel is in transfer mode and the correct transfer channel is selected in the project settings. - Event ID: 1000050
- Alarm archive overflow — the alarm buffer on the HMI device has reached its maximum capacity
Acknowledge and clear existing alarms, increase the alarm buffer size in the project configuration, or enable automatic archiving to external storage.
Frequently Asked Questions
Which SIMATIC PLCs are compatible with WinCC flexible 2008?
WinCC flexible 2008 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs. Communication is possible via MPI, PROFIBUS DP, and Industrial Ethernet depending on the PLC and panel hardware used.
What HMI panel hardware is supported by this software?
The software supports the full range of Siemens SIMATIC HMI panels including TP (Touch Panel), OP (Operator Panel), MP (Multi Panel), and Mobile Panel series. Compatibility depends on the specific panel firmware version.
Does WinCC flexible 2008 include an offline simulation feature?
Yes, WinCC flexible 2008 includes an integrated project simulator that allows engineers to test and validate HMI projects on a PC without requiring a physical panel or PLC connection.
Is WinCC flexible 2008 compatible with Windows 10?
WinCC flexible 2008 was designed for Windows XP, Vista, and Windows 7. It is not officially supported on Windows 10; for newer operating systems, Siemens recommends migrating to WinCC (TIA Portal).
Can projects created in WinCC flexible 2008 be migrated to TIA Portal?
Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible 2008 projects. Some manual rework may be required depending on the complexity of the original project.
Troubleshooting
WinCC flexible 2008 fails to start and displays a license error
Open the Siemens Automation License Manager (ALM) to check whether a valid license for WinCC flexible 2008 is present and not expired or corrupted.
Transfer a valid license using the ALM tool from a license dongle or backup. If the license is corrupted, contact Siemens support for license recovery procedures.
Project transfer to HMI panel fails repeatedly
Check the transfer channel settings in the project (Ethernet, USB, or MPI/PROFIBUS) and verify the panel is set to transfer mode. Confirm the IP address or communication parameters match between the engineering PC and the panel.
Correct the transfer channel configuration, ensure the panel is in transfer mode by holding the appropriate key during boot, and retry the transfer. Replace the transfer cable if a hardware fault is suspected.
Runtime project on the HMI panel shows communication errors to the PLC
Verify the PLC address, subnet, and communication protocol configured in the WinCC flexible project match the actual PLC settings. Check physical cabling and network switch status.
Correct the PLC connection parameters in the project, re-transfer the updated project to the panel, and verify network continuity using a cable tester or ping command.
Alarm display on the HMI panel is not updating or showing stale alarms
Check the alarm tag addresses in the project to confirm they correspond to the correct PLC bit addresses. Verify the PLC program is writing to the expected alarm bits.
Correct any mismatched tag addresses in the WinCC flexible project, re-transfer the project, and confirm the PLC logic is correctly setting and resetting alarm bits.
WinCC flexible 2008 installation fails or crashes during setup on the engineering PC
Check the Windows version compatibility and ensure all required Microsoft prerequisites such as .NET Framework and Visual C++ redistributables are installed. Review the installation log file for specific error codes.
Install all required prerequisites manually before re-running the WinCC flexible 2008 installer. Disable antivirus software temporarily during installation and ensure the user account has local administrator privileges.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page



