
Siemens 6AV6381-2BD08-0AH0 WinCC flexible 2008
€ 1.995,00
The Siemens 6AV6381-2BD08-0AH0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across the SIMATIC HMI range.
WinCC flexible 2008 offers a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and scripting via VBScript. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet (PROFINET). It includes a library of pre-built faceplates and symbols, supports multi-language project configuration, and provides simulation capabilities for offline testing of HMI projects without physical hardware. The 2008 edition introduced improved performance, extended panel support, and enhanced integration with the broader SIMATIC engineering environment.
WinCC flexible 2008 is widely used in manufacturing, process automation, machine building, and plant engineering applications. It is suitable for configuring operator panels such as the SIMATIC TP, OP, MP, and Mobile Panel series, making it applicable across industries including automotive, food and beverage, chemical processing, and packaging. The software is particularly valued in environments where standardized SIMATIC infrastructure is already deployed, enabling seamless integration between HMI visualization and PLC control layers.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| Software Type | Engineering Software / HMI Configuration Tool |
| Compatible PLC Families | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces | MPI, PROFIBUS DP, PROFINET / Industrial Ethernet |
| Supported Panel Series | SIMATIC TP, OP, MP, Mobile Panel |
| Scripting Support | VBScript |
| Operating System | Windows XP, Windows Vista, Windows 7 (32-bit) |
| Project Simulation | Integrated offline simulator included |
| Language Support | Multi-language project configuration |
| Series/Product Family | SIMATIC WinCC flexible |
| License Type | Single-user software license |
| Certifications | CE |
Common Error Codes & System Events
- Event ID: 1000000
- Runtime startup error — WinCC flexible Runtime failed to initialize correctly.
Check that all required runtime components are installed. Reinstall the WinCC flexible 2008 runtime package and verify the license dongle or software license is correctly activated. - Event ID: 1000001
- Communication error — Connection to the configured PLC could not be established.
Verify PLC communication settings (IP address, MPI address, or PROFIBUS address) in the project. Check physical connections and ensure the correct communication driver is installed on the PC. - Event ID: 1000002
- License not found — No valid license detected for WinCC flexible 2008.
Insert the USB license dongle or use the Siemens Automation License Manager (ALM) to verify and activate the software license. Ensure the correct license edition matches the project scope. - Event ID: 1000003
- Tag update error — One or more tags could not be read from or written to the connected controller.
Check tag addressing in the project configuration. Verify that the PLC data blocks and memory areas referenced by the tags exist and are accessible. - Event ID: 1000004
- Alarm logging error — The alarm system failed to log or display alarms correctly.
Check the alarm configuration in the project. Verify that the alarm log file path is accessible and that sufficient disk space is available on the runtime PC. - Event ID: 1000005
- Recipe data error — Recipe records could not be read from or written to the target device or storage medium.
Verify recipe configuration and ensure the target storage path (panel memory, USB, or network share) is accessible and has sufficient free space. - Event ID: 1000006
- Project download error — The project could not be transferred to the target HMI panel.
Check the transfer connection settings (USB, Ethernet, or MPI). Ensure the panel is in transfer mode and that the project was compiled without errors before initiating the download. - Event ID: 1000007
- Simulation error — The integrated simulator encountered an error during project simulation.
Ensure the project compiles without errors before starting the simulation. Check that the PC meets the minimum system requirements for WinCC flexible 2008 and that no conflicting software is running.
Frequently Asked Questions
Which SIMATIC HMI panels are supported by WinCC flexible 2008?
WinCC flexible 2008 supports the full range of SIMATIC HMI panels including the TP (Touch Panel), OP (Operator Panel), MP (Multi Panel), and Mobile Panel series. Specific panel models supported depend on the edition of WinCC flexible 2008 installed.
Is WinCC flexible 2008 compatible with TIA Portal projects?
WinCC flexible 2008 is not natively compatible with TIA Portal. However, Siemens provides a migration tool within TIA Portal that allows WinCC flexible projects to be imported and converted for use in the TIA Portal engineering environment.
What operating systems are supported by WinCC flexible 2008?
WinCC flexible 2008 is designed to run on Windows XP (SP3), Windows Vista, and Windows 7 (32-bit). It is not officially supported on Windows 8, Windows 10, or Windows 11.
Does WinCC flexible 2008 require a hardware dongle for licensing?
Licensing can be managed either via a USB hardware dongle or through the Siemens Automation License Manager (ALM) software. The license must be present on the engineering PC for the software to operate.
Can WinCC flexible 2008 communicate with S7-1200 PLCs?
Yes, WinCC flexible 2008 supports communication with SIMATIC S7-1200 PLCs via PROFINET/Industrial Ethernet, provided the appropriate communication drivers are installed and the project is configured correctly.
Troubleshooting
WinCC flexible 2008 fails to start or crashes on launch
Check the Windows Event Viewer for application errors related to WinCC flexible. Verify that all prerequisite software components (e.g., Microsoft .NET Framework, SIMATIC communication drivers) are correctly installed.
Reinstall the WinCC flexible 2008 software ensuring all components are selected during installation. Verify that the PC meets the minimum hardware and OS requirements, and that no conflicting HMI or SCADA software is installed simultaneously.
Project cannot be downloaded to the HMI panel
Confirm the transfer connection type (USB, Ethernet, or MPI/PROFIBUS) is correctly configured in the project transfer settings. Check that the panel is set to transfer mode and is reachable from the engineering PC.
Verify network or cable connections between the PC and the panel. Ensure the panel firmware version is compatible with the WinCC flexible 2008 project version. Recompile the project and retry the transfer.
Runtime communication to PLC is lost intermittently
Check the physical communication link (Ethernet cable, PROFIBUS cable, or MPI adapter). Review the tag update cycle times in the project and compare with PLC scan cycle times.
Replace or reseat communication cables. Adjust tag update cycles to reduce communication load. Verify PLC communication parameters match those configured in the WinCC flexible project.
License error appears when opening WinCC flexible 2008
Open the Siemens Automation License Manager (ALM) and check whether a valid WinCC flexible 2008 license is listed and active. Verify the USB dongle is connected if a hardware license is used.
If the license is missing or expired, transfer a valid license using the ALM tool. If using a USB dongle, try a different USB port or reinstall the dongle drivers. Contact Siemens license support if the license cannot be recovered.
Compiled project generates errors or warnings during compilation
Review the compilation output log in WinCC flexible 2008 for specific error messages. Common causes include invalid tag references, unsupported functions for the target panel type, or exceeded memory limits.
Correct all tag addressing errors and ensure all referenced data blocks exist in the PLC program. Remove or replace functions not supported by the target panel hardware, and reduce project size if memory limits are exceeded.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page



