Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00
The Siemens OP27 (part number 6AV3627-1QK00-0AX0) is a monochrome operator panel belonging to the SIMATIC HMI OP series, designed for human-machine interface applications in industrial automation environments. It provides a compact and robust interface for process visualization, parameter input, and machine control. The OP27 is part of Siemens' established SIMATIC HMI portfolio and is intended for use with SIMATIC S5 and S7 programmable logic controllers.
The 6AV3627-1QK00-0AX0 features a 5.5-inch STN monochrome LCD display with a resolution of 240 x 128 pixels and an integrated membrane keypad for operator input. It supports serial communication interfaces including RS-232 and RS-422/RS-485, enabling connectivity to a range of Siemens PLCs and third-party controllers. The panel operates on a 24 V DC supply and is configured using Siemens ProTool software. It offers a protection rating of IP65 on the front face, making it suitable for panel-mount installations in industrial enclosures.
The OP27 is widely deployed in manufacturing, process automation, and machine tool applications where a reliable and straightforward operator interface is required. Its compatibility with SIMATIC S7-200, S7-300, and S7-400 PLCs, as well as legacy S5 systems, makes it a versatile choice for both new installations and system upgrades. The panel is commonly found in packaging machinery, conveyor systems, and general-purpose industrial control panels.
Technical Specifications
| Display Size | 5.5 inch |
|---|---|
| Display Type | STN monochrome LCD |
| Display Resolution | 240 x 128 pixels |
| Input Type | Membrane keypad |
| Input/Operating Voltage | 24 V DC |
| Communication Interface | RS-232, RS-422/RS-485 |
| IP/Protection Rating | IP65 (front face) |
| Operating Temperature | 0 °C to 50 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| Mounting | Panel mount |
| Series/Product Family | SIMATIC HMI OP series |
| Configuration Software | Siemens ProTool |
Common Error Codes & System Events
- Event ID: 1000
- Communication error between OP27 and connected PLC. The panel cannot establish or maintain a connection to the controller.
Check serial cable wiring and connections. Verify communication parameters (baud rate, parity, station address) match the PLC configuration. Inspect RS-232/RS-485 interface for damage. - Event ID: 1003
- Timeout error during communication with the PLC. The panel did not receive a response within the expected time window.
Check for loose or damaged communication cables. Verify PLC is in RUN mode and responding. Reduce cable length or check for electrical interference on the communication line. - Event ID: 1004
- Configuration data mismatch. The project loaded on the OP27 does not match the connected PLC or its configuration.
Re-download the correct project to the OP27 using ProTool. Ensure the PLC type and communication settings in the project match the actual hardware. - Event ID: 1200
- Internal memory error detected. The panel has identified a fault in its internal data storage.
Perform a panel reset. If the error persists, reload the project via ProTool. A hardware fault may require panel repair or replacement. - Event ID: 1300
- Operating system or firmware error. The panel firmware may be corrupted or incompatible.
Re-flash the panel firmware using the appropriate Siemens update tool. Ensure the firmware version is compatible with the ProTool project version. - Event ID: 1500
- Power supply undervoltage detected. The 24 V DC supply voltage has dropped below the acceptable operating threshold.
Measure the supply voltage at the panel connector. Ensure the power supply output is stable at 24 V DC and can deliver sufficient current. Check wiring for voltage drop.
Frequently Asked Questions
What PLC systems is the OP27 (6AV3627-1QK00-0AX0) compatible with?
The OP27 is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs, as well as legacy S5 series controllers. It can also communicate with certain third-party controllers via its serial interfaces.
What software is used to configure and program the OP27?
The OP27 is configured using Siemens ProTool software. Projects are created on a PC and then downloaded to the panel via a serial connection.
What is the supply voltage requirement for the 6AV3627-1QK00-0AX0?
The OP27 requires a 24 V DC power supply. Ensure the supply is stable and capable of delivering sufficient current for reliable operation.
What is the front panel protection rating of the OP27?
The OP27 has an IP65 protection rating on the front face, making it resistant to dust ingress and low-pressure water jets when correctly installed in a panel cutout.
Does the OP27 support touch input?
No, the OP27 does not feature a touchscreen. Operator input is performed exclusively via the integrated membrane keypad on the front panel.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the panel power connector. Verify the supply polarity is correct and the voltage is within specification. Inspect internal fuses if accessible.
Restore correct 24 V DC supply. If the supply is confirmed good and the display remains blank, the internal power supply board or backlight may be faulty and require repair or replacement.
Communication fault displayed on screen, no connection to PLC
Verify the serial cable wiring between the OP27 and the PLC. Check that baud rate, parity, data bits, stop bits, and station address configured in ProTool match the PLC settings exactly.
Correct any wiring errors and update communication parameters in the ProTool project, then re-download to the panel. Replace the serial cable if damaged or use a known-good cable for testing.
Panel keypad buttons not responding or responding incorrectly
Inspect the membrane keypad for physical damage, contamination, or wear. Test individual keys to identify whether the fault is isolated to specific buttons or affects the entire keypad.
Clean the keypad surface. If individual keys are unresponsive due to wear or damage, the membrane keypad assembly will need to be replaced.
Project download from ProTool fails or is interrupted
Check the serial cable connection between the PC and the OP27. Verify the correct COM port is selected in ProTool and that no other application is using the port. Confirm the panel is in transfer mode.
Switch the OP27 to transfer mode via the panel menu. Use a known-good serial cable and confirm ProTool communication settings match the panel configuration. Retry the download.
Display shows corrupted characters or garbled text
This may indicate a firmware issue, corrupted project data, or a failing display module. Check if the issue appeared after a power interruption during a project download.
Re-download the project using ProTool to restore correct display data. If the issue persists, re-flash the panel firmware. A persistently corrupted display may indicate a hardware fault requiring panel repair.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page