• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AE32-0BJ0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AE32-0BJ0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AE32-0BJ0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AE32-0BJ0 is an industrial Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is a high-performance, fanless or fan-cooled industrial computing platform designed for demanding HMI and SCADA applications in automation environments. The unit integrates a flat-panel display with an embedded PC architecture, providing a compact all-in-one solution for machine-level visualization and control.

    The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen or keyboard/mouse operation depending on configuration. It is equipped with an Intel processor platform, supports Windows XP Professional or Windows 2000 as the operating system, and provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial COM ports. The unit is designed for 24 V DC supply input and is built to IEC 61131-2 standards for industrial environments, with an IP65 protection rating on the front panel.

    The SIMATIC Panel PC 670 is widely used in the automotive, food and beverage, chemical, and machine building industries where a robust, integrated PC-based HMI solution is required. It is suitable for applications demanding real-time data visualization, recipe management, and integration with Siemens SIMATIC S7 PLCs via PROFIBUS or Industrial Ethernet. Its rugged construction and industrial-grade components make it appropriate for continuous operation in harsh factory floor environments.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT color LCD
    Input Voltage 24 V DC
    IP Protection Rating (Front) IP65
    Operating System Windows XP Professional / Windows 2000
    Communication Interfaces Ethernet (RJ45), USB, RS-232 (COM ports), PROFIBUS (optional)
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 95% (non-condensing)
    Mounting Panel mounting
    Series SIMATIC Panel PC 670
    Certifications CE, UL, cULus
    Display Colors 256 colors / up to 16 million colors (TFT)

    Common Error Codes and System Events

    Event ID: 1000
    Application error – a software application on the Panel PC has encountered an unexpected fault and terminated.
    Check the Windows Event Viewer for detailed error logs. Restart the affected application or reinstall the software if the issue persists.
    Event ID: 6008
    Unexpected shutdown – the system was not shut down cleanly, indicating a possible power loss or system crash.
    Check the 24 V DC power supply for stability and correct voltage. Inspect the power connector and cabling. Review event logs for preceding errors.
    BIOS POST Error
    Hardware fault detected during Power-On Self-Test, which may indicate a memory, CPU, or hardware component failure.
    Reseat RAM modules and check all internal connections. If the error persists, replace the faulty hardware component or return the unit for repair.
    Watchdog Timeout
    The system watchdog timer has expired, indicating the operating system or application has become unresponsive.
    Investigate software processes causing system hang. Ensure the OS and application software are correctly configured. Check for memory or CPU overload conditions.
    Hard Disk Error
    The internal CompactFlash card or hard disk drive has reported a read/write error or is not detected.
    Check the storage device connection. Replace the CompactFlash card or HDD if faulty. Restore the OS and application image from backup.
    Network Connection Lost
    The Ethernet interface has lost communication with the network or PLC, causing HMI communication failure.
    Verify Ethernet cable integrity and switch/hub connections. Check IP address configuration and ensure the PLC communication driver is correctly configured in the HMI software.
    Temperature Warning
    The internal temperature sensor has detected an elevated operating temperature approaching the thermal limit.
    Check that ventilation slots are unobstructed. Verify ambient temperature is within specification (0–45 °C). Clean any dust from cooling vents or fan assemblies.

    Frequently Asked Questions

    What is the supply voltage for the Siemens 6AV7612-0AE32-0BJ0?

    The unit operates on a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance range.

    What operating system does the SIMATIC Panel PC 670 support?

    The Panel PC 670 supports Windows XP Professional and Windows 2000. The specific OS installed depends on the factory configuration ordered.

    What is the front panel protection rating of this Panel PC?

    The front panel of the 6AV7612-0AE32-0BJ0 carries an IP65 protection rating, making it resistant to dust and water jets, suitable for industrial panel mounting.

    Is this Panel PC compatible with Siemens SIMATIC S7 PLCs?

    Yes, the SIMATIC Panel PC 670 can communicate with SIMATIC S7-300 and S7-400 PLCs via Industrial Ethernet or PROFIBUS using WinCC or SIMATIC ProTool/Pro runtime software.

    Can the storage medium on this Panel PC be replaced or upgraded?

    Yes, the Panel PC 670 supports CompactFlash cards or an internal hard disk drive as the storage medium, which can be replaced or upgraded. Always restore the OS and application image after replacement.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the power connector. Verify the backlight is functioning by shining a light at the screen to check for a faint image. Inspect internal fuse and power supply board.

    Replace the backlight inverter or LCD panel if the backlight has failed. If no power is reaching the unit, check the supply wiring and fuse. Replace the internal power supply module if the voltage is absent at the board.

    Touchscreen does not respond or is inaccurate

    Check if the touch controller is recognized in Windows Device Manager. Verify the touch calibration settings within the operating system. Inspect the touch overlay for physical damage or contamination.

    Recalibrate the touchscreen using the Windows calibration utility. Clean the touch surface with a soft cloth. If the touch controller is not detected, reinstall the driver or replace the touch overlay assembly.

    Panel PC fails to boot and shows BIOS error or blank screen with no POST

    Reseat the RAM modules and check the CompactFlash or HDD connection. Listen for any BIOS beep codes that indicate specific hardware faults. Check for any loose internal connectors.

    Reseat or replace the RAM. Replace the CompactFlash card or HDD and restore the OS image. If the motherboard is faulty, the unit will require board-level repair or replacement.

    Communication with PLC is lost or intermittent

    Check the Ethernet or PROFIBUS cable connections at both the Panel PC and the PLC. Verify the IP address and subnet configuration in the OS network settings. Check the communication driver configuration in the HMI runtime software.

    Replace damaged cables and ensure connectors are properly seated. Reconfigure the network settings and communication driver parameters. Restart the HMI runtime application and verify the PLC is online.

    System runs slowly or application freezes

    Check CPU and RAM utilization using Windows Task Manager. Inspect the CompactFlash or HDD for available storage space and file system errors. Check for background processes consuming excessive resources.

    Close unnecessary background applications. Run a disk check utility to repair file system errors. If the storage medium is nearly full, archive data and free up space. Consider replacing the CompactFlash card with a higher-capacity unit if storage is insufficient.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart