• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AE32-0CE0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AE32-0CE0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AE32-0CE0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AE32-0CE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial-grade panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a high-resolution display with a powerful computing platform in a compact, panel-mount enclosure suitable for control cabinet integration.

    The SIMATIC Panel PC 670 6AV7612-0AE32-0CE0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs Microsoft Windows XP or Windows XP Embedded, providing compatibility with standard SCADA and HMI software packages including WinCC and WinCC flexible. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), and is built to withstand industrial environments with a front panel protection rating of IP65.

    The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, automotive production, and machine tool industries where a robust, integrated PC-based HMI solution is required. Its compatibility with Siemens SIMATIC software and standard PC operating systems makes it suitable for complex visualization tasks, data logging, and process control applications. The fanless or low-noise design options and industrial-grade components ensure reliable long-term operation in harsh production environments.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT color LCD
    Touch Technology Resistive touch screen
    Input Voltage 24 V DC
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Communication Interfaces Ethernet (RJ45), USB 2.0, RS-232
    Operating System Windows XP / Windows XP Embedded
    Mounting Panel mounting
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    System startup error — the operating system failed to boot correctly or a critical system file is missing.
    Check the hard disk or CompactFlash card for errors. Reinstall or restore the operating system image if necessary.
    Event ID: 1001
    Application crash or unexpected software termination detected by Windows error reporting.
    Review Windows Event Viewer logs to identify the faulting application. Update or reinstall the HMI software (e.g. WinCC).
    Hardware Watchdog Timeout
    The hardware watchdog timer has triggered, indicating the system became unresponsive.
    Check CPU load and running processes. Ensure the watchdog application is correctly configured and that the system is not overloaded.
    Temperature Warning
    Internal system temperature has exceeded the warning threshold.
    Check ambient temperature and ensure ventilation clearances are maintained. Clean any dust filters and verify cooling components are functional.
    Fan Failure
    System fan has stopped or is operating below the minimum speed threshold.
    Replace the defective fan. Ensure the replacement fan meets the original specification for the Panel PC 670.
    Battery Low
    The CMOS/RTC backup battery voltage is below the minimum threshold, risking loss of BIOS settings and real-time clock data.
    Replace the internal CMOS battery (typically CR2032). After replacement, reconfigure BIOS settings and synchronize the system clock.
    Display No Signal
    The display controller is not receiving a valid video signal from the mainboard.
    Check the internal display cable connections between the mainboard and the display panel. Replace the display cable or mainboard if the fault persists.
    Ethernet Link Failure
    The Ethernet interface has lost network connectivity or cannot establish a link.
    Check the network cable and switch port. Verify network adapter settings in the operating system Device Manager. Replace the network cable or adapter if necessary.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7612-0AE32-0CE0?

    The SIMATIC Panel PC 670 6AV7612-0AE32-0CE0 operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.

    What operating system does this Panel PC run?

    This unit is designed to run Microsoft Windows XP or Windows XP Embedded, providing compatibility with standard industrial HMI and SCADA software packages.

    Is this Panel PC compatible with Siemens WinCC?

    Yes, the SIMATIC Panel PC 670 is fully compatible with Siemens WinCC and WinCC flexible visualization software, making it a common platform for Siemens-based automation systems.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7612-0AE32-0CE0 carries an IP65 protection rating, making it resistant to dust ingress and water jets, suitable for industrial panel mounting.

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45), USB 2.0 ports, and RS-232 serial interfaces, enabling connectivity to PLCs, networks, and peripheral devices.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power connector. Verify the internal display cable connection between the mainboard and the TFT panel. Check if the power LED is illuminated.

    Restore the 24 V DC supply if absent. Reseat or replace the internal display cable. If the mainboard power LED is on but the display is blank, the TFT panel or backlight inverter may need replacement.

    Touch screen does not respond or is inaccurate

    Check if the touch controller is recognized in Windows Device Manager. Verify that the touch screen calibration has not been lost. Inspect the touch screen overlay for physical damage.

    Recalibrate the touch screen using the Windows calibration utility. Reinstall the touch screen driver if the device is not recognized. Replace the touch screen overlay if physically damaged.

    System fails to boot or continuously restarts

    Check the CompactFlash card or hard disk for errors using a bootable diagnostic tool. Verify that the BIOS settings are correct and that the boot device is properly selected.

    Run a disk check and repair corrupted system files. Restore the operating system image from a backup. Replace the CompactFlash card or hard disk if hardware failure is confirmed.

    Ethernet communication not working

    Verify the network cable and switch port are functional. Check the network adapter status in Windows Device Manager. Confirm IP address configuration is correct.

    Replace the network cable if faulty. Reinstall the Ethernet adapter driver if it shows an error in Device Manager. Reconfigure the IP settings to match the network requirements.

    BIOS settings reset after power cycle

    The CMOS backup battery is likely discharged. Measure the battery voltage; it should be approximately 3 V DC for a CR2032 cell.

    Replace the internal CMOS battery with a new CR2032 cell. After replacement, re-enter the correct BIOS settings and verify the system clock is synchronized.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart