• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AE32-0BH0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AE32-0BH0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AE32-0BH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AE32-0BH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. The unit integrates a display, computing hardware, and industrial-grade I/O into a single compact panel-mount enclosure.

    The SIMATIC Panel PC 670 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch screen technology. It is powered by an Intel Celeron processor and runs Microsoft Windows operating systems, supporting SIMATIC WinCC and other Siemens HMI software packages. The unit provides communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), enabling integration with PROFIBUS and Industrial Ethernet networks. The front panel meets IP65 protection rating, making it suitable for use in environments where dust and water ingress are a concern.

    The SIMATIC Panel PC 670 is widely used in the automotive, food and beverage, chemical, and manufacturing industries for process visualization, SCADA applications, and machine control interfaces. Its rugged industrial design and compatibility with Siemens SIMATIC software make it a reliable choice for applications requiring a full PC platform embedded directly into a control panel. The unit is particularly suited for installations where standard PC functionality combined with industrial robustness and panel-mount form factor is required.

    Technical Specifications

    Display Size 12.1 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT Color LCD
    Touch Technology Resistive Touch Screen
    Input/Operating Voltage 24 V DC
    IP/Protection Rating IP65 (front panel)
    Communication Interface Ethernet (RJ45), USB, RS-232/RS-422/RS-485
    Operating System Microsoft Windows XP / Windows 2000
    Processor Intel Celeron
    Mounting Panel Mount
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 95% (non-condensing)
    Certifications CE, UL
    Series/Product Family SIMATIC Panel PC 670

    Common Error Codes and System Events

    Event ID: 100
    System startup error — the operating system failed to boot correctly or a critical system file is missing or corrupted.
    Check the hard disk or CompactFlash card for errors. Reinstall or restore the operating system image using the Siemens recovery media.
    Event ID: 1000
    Application fault — the HMI or SCADA application (e.g. WinCC) has crashed or encountered an unhandled exception.
    Review the Windows Event Viewer application log for details. Reinstall or update the affected software. Check for memory or hardware conflicts.
    Event ID: 7000
    Service control manager error — a required Windows service failed to start during system boot.
    Check the Windows Event Viewer system log for the specific service name. Ensure all required drivers and services are correctly installed and configured.
    Hardware Error: HDD
    Hard disk drive failure or read/write error detected.
    Run a disk diagnostic utility. Replace the hard disk drive or CompactFlash storage module if errors are confirmed. Restore the system image from backup.
    Hardware Error: RAM
    Memory module failure or insufficient RAM detected during POST or runtime.
    Reseat the RAM module. If the error persists, replace the RAM module with a Siemens-approved compatible module.
    Display Error: No Signal
    The display shows no image or backlight is on but no content is visible, indicating a graphics or connection fault.
    Check the internal display cable connections. Verify graphics driver installation. Replace the backlight inverter or display panel if hardware fault is confirmed.
    Network Error: Link Down
    Ethernet interface is not establishing a network link, preventing communication with PLCs or SCADA servers.
    Check the Ethernet cable and switch port. Verify network adapter settings in Windows Device Manager. Replace the Ethernet cable or network adapter if faulty.
    WinCC Runtime Error
    Siemens WinCC runtime application reports a communication error or tag connection failure to the connected PLC or controller.
    Verify the communication channel configuration in WinCC. Check the PLC connection and network settings. Restart the WinCC runtime and confirm tag addresses are correctly mapped.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7612-0AE32-0BH0?

    The unit operates on 24 V DC supply voltage, which is standard for SIMATIC Panel PC 670 devices.

    What communication interfaces are available on this Panel PC?

    The 6AV7612-0AE32-0BH0 provides Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), supporting connectivity to Industrial Ethernet and PROFIBUS networks via appropriate adapters.

    Is this Panel PC compatible with Siemens WinCC?

    Yes, the SIMATIC Panel PC 670 is designed to run Siemens SIMATIC WinCC and other PC-based HMI and SCADA software packages under Windows XP or Windows 2000.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7612-0AE32-0BH0 meets IP65 protection rating, providing protection against dust ingress and water jets.

    What display size and resolution does this Panel PC have?

    The unit features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and a resistive touch screen interface.

    Troubleshooting

    Panel PC does not power on after 24 V DC is applied

    Measure the 24 V DC supply voltage at the power input connector. Check for blown internal fuses or a faulty power supply module.

    Ensure the supply voltage is within the specified 24 V DC range. Replace any blown fuses. If the internal power supply module is faulty, replace it with a compatible Siemens spare part.

    Display is blank or shows no image despite the unit appearing to be powered

    Check whether the backlight is functioning by shining a light at the screen to detect a faint image. Inspect internal display cable connections and verify the graphics driver is correctly installed in Windows Device Manager.

    Replace the backlight inverter board if the backlight has failed. Reseat or replace the internal display cable if loose or damaged. Reinstall the graphics driver if a software fault is identified.

    Touch screen does not respond or registers incorrect touch positions

    Verify that the touch screen driver is correctly installed in Windows. Run the touch screen calibration utility available in the Windows Control Panel or Siemens configuration tools.

    Recalibrate the touch screen using the built-in calibration tool. If calibration does not resolve the issue, replace the resistive touch screen overlay or the touch controller board.

    Unit fails to communicate with connected PLCs over Ethernet

    Check the Ethernet cable connection and verify the link LED on the RJ45 port is active. Confirm the IP address configuration in Windows network settings matches the target network. Check WinCC channel configuration.

    Replace the Ethernet cable if damaged. Reconfigure the IP address settings to match the network. Verify and correct the WinCC communication channel and PLC connection parameters.

    System boots slowly or freezes during Windows startup

    Check the hard disk drive or CompactFlash storage for errors using Windows disk diagnostic tools. Review the Windows Event Viewer for startup errors. Check available RAM and CPU load.

    Run a disk check and repair utility (chkdsk). If the storage medium is failing, replace the hard disk drive or CompactFlash card and restore the system image from a Siemens recovery backup.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart