Siemens 6AV7612-0AE12-0CJ0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AE12-0CJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, enabling it to run standard Windows-based SCADA and HMI software alongside process control applications.
The SIMATIC Panel PC 670 features a 12.1-inch TFT LCD display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is built around an industrial-grade processor platform and supports communication via standard interfaces including Ethernet, USB, and serial ports. The unit is designed for panel mounting with an IP65 protection rating on the front face, making it resistant to dust and water ingress from the front. It operates on a 24 V DC supply and is compatible with Siemens WinCC and other SIMATIC HMI software packages.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine tool industries where a robust, panel-integrated PC solution is required. Its compatibility with Siemens SIMATIC software and standard Windows operating systems makes it suitable for integration into existing Siemens automation architectures. Typical applications include production line visualization, process monitoring, and machine control panels in automotive, chemical, and food and beverage industries.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Communication Interface | Ethernet (RJ45), USB, Serial (RS-232) |
| Operating System Compatibility | Windows XP / Windows CE (depending on configuration) |
| Mounting | Panel mounting |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Certifications | CE, UL |
| Series | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat storage media. Replace storage device if corrupted. - Event ID: 200
- Watchdog timeout triggered due to application or system hang.
Restart the Panel PC. Check the running application for software loops or memory leaks. Update or reinstall the HMI application software. - Event ID: 300
- Fan failure or thermal warning detected. Internal temperature exceeding threshold.
Check and clean ventilation slots. Verify ambient temperature is within specification. Replace the internal cooling fan if faulty. - Event ID: 400
- Ethernet communication link failure or network interface not detected.
Check Ethernet cable connection and network switch. Verify IP address configuration in Windows network settings. Replace Ethernet cable or check RJ45 connector. - Event ID: 500
- Touchscreen calibration error or touch input not responding correctly.
Recalibrate the touchscreen via the Windows control panel or SIMATIC HMI settings. If calibration fails, check the touch controller connection internally or replace the touch overlay. - Event ID: 600
- Power supply undervoltage detected. Supply voltage below acceptable threshold.
Measure the 24 V DC supply at the power connector. Ensure the supply is within the specified voltage range. Check wiring and power supply unit output. - Event ID: 700
- Hard disk or storage media read/write error detected.
Run a disk check utility (chkdsk) on the storage device. Back up data and replace the hard disk or CompactFlash card if errors persist.
Frequently Asked Questions
What display size and resolution does the 6AV7612-0AE12-0CJ0 have?
The unit features a 12.1-inch TFT LCD display with a resolution of 800 x 600 pixels (SVGA) and a resistive touchscreen interface.
What is the supply voltage for this Panel PC?
The SIMATIC Panel PC 670 operates on a 24 V DC power supply.
What software is compatible with this Panel PC?
The unit is compatible with Siemens SIMATIC WinCC, WinCC flexible, and other standard Windows-based HMI and SCADA software packages.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AE12-0CJ0 carries an IP65 protection rating, providing full dust protection and protection against water jets.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), USB ports, and serial RS-232 interfaces for connectivity to PLCs, networks, and peripheral devices.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the internal power supply is functioning and that the backlight inverter is operational.
Ensure the supply voltage is stable at 24 V DC. If the backlight is faulty, replace the backlight inverter or the display assembly. Check internal fuse if supply voltage is confirmed correct.
Touchscreen does not respond or registers incorrect touch positions
Attempt to recalibrate the touchscreen through the Windows Control Panel or SIMATIC HMI configuration tool. Check for physical damage or contamination on the touch surface.
Perform a full touchscreen recalibration. Clean the touch surface with a soft cloth. If recalibration fails repeatedly, replace the resistive touch overlay or check the internal touch controller connection.
Panel PC fails to boot or gets stuck during startup
Check the storage device (hard disk or CompactFlash card) for errors using a bootable diagnostic tool. Verify BIOS settings are correct and that the boot device is detected.
Run chkdsk or equivalent disk diagnostic. If the storage device is corrupted, restore the system image from backup or replace the storage media and reinstall the operating system and HMI software.
Ethernet communication not established with PLC or network
Verify the Ethernet cable is connected and the link LED on the RJ45 port is active. Check the IP address configuration in Windows network settings matches the network subnet.
Replace the Ethernet cable if no link LED is present. Reconfigure the IP address settings. If the network interface is not detected by Windows, update the network adapter driver or replace the unit if the interface is hardware-faulty.
Unit shuts down unexpectedly or triggers watchdog reset
Check the ambient temperature around the Panel PC and verify ventilation slots are not blocked. Review Windows event logs for application errors or system crashes prior to shutdown.
Clean ventilation slots and ensure ambient temperature is within 0 °C to +50 °C. Identify and resolve any software application causing system hangs. Replace the internal cooling fan if thermal shutdown is confirmed.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page