Siemens 6AV7612-0AE12-0CH0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AE12-0CH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial-grade panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a flat-panel display with a full PC architecture, providing both operator interface and computing functionality in a single device.
The SIMATIC Panel PC 670 6AV7612-0AE12-0CH0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is built around an x86-compatible processor platform and is equipped with interfaces including USB, Ethernet (RJ45), and serial ports (RS-232/RS-422/RS-485) to support connectivity with PLCs and peripheral devices. The unit is designed for front-panel mounting with an IP65 protection rating on the front face, making it suitable for use in environments where dust and water ingress are a concern. It operates on a 24 V DC supply and is compatible with Windows-based operating systems, supporting SIMATIC WinCC and other Siemens HMI software packages.
The SIMATIC Panel PC 670 is widely deployed in manufacturing, process automation, and machine tool industries where a combination of robust visualization and local computing power is required. Its compact panel-mount design makes it suitable for integration into control cabinets and operator panels on production lines, packaging machinery, and conveyor systems. The ability to run standard PC software alongside SIMATIC HMI applications makes it a versatile choice for complex visualization and data acquisition tasks.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touch screen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet RJ45, USB, RS-232, RS-422/RS-485 |
| Mounting | Panel mounting (front) |
| Series/Product Family | SIMATIC Panel PC 670 |
| Operating System Compatibility | Windows XP / Windows 2000 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to load correctly during boot sequence.
Check the hard disk or CompactFlash card for integrity. Reinstall or restore the operating system image if corrupted. - Event ID: 101
- Hardware initialization failure — a hardware component such as RAM or CPU was not detected correctly during POST.
Reseat internal memory modules and check all internal connectors. Replace faulty hardware components as necessary. - Event ID: 200
- Watchdog timeout — the system watchdog detected that the application stopped responding within the defined time window.
Restart the application. Check for software deadlocks or excessive CPU load. Update or reinstall the HMI runtime software. - Event ID: 201
- Communication loss to PLC — the HMI runtime lost its communication connection to the configured PLC or controller.
Verify Ethernet or serial cable connections. Check PLC IP address and communication settings in WinCC or ProTool configuration. - Event ID: 300
- Touch screen calibration error — the touch input is misaligned or unresponsive after system startup.
Run the touch screen calibration utility from the Windows Control Panel or SIMATIC HMI service menu. Clean the touch surface. - Event ID: 400
- Fan failure warning — the internal cooling fan has stopped or is operating below the minimum required speed.
Inspect and clean the fan. Replace the internal fan unit if it is not spinning. Ensure adequate ventilation around the panel. - Event ID: 500
- Battery low warning — the CMOS backup battery voltage has dropped below the minimum threshold.
Replace the internal CMOS lithium battery (CR2032 or equivalent). Reconfigure BIOS settings after replacement. - Event ID: 600
- Storage medium error — read/write errors detected on the hard disk or CompactFlash storage device.
Run a disk check utility. Back up data and replace the storage medium if errors persist. Restore the system image from backup.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AE12-0CH0?
The unit operates on a 24 V DC power supply. Ensure the supply is within the specified tolerance range before powering on the device.
What HMI software is compatible with this Panel PC?
The SIMATIC Panel PC 670 is compatible with Siemens SIMATIC WinCC and ProTool/Pro HMI software packages. It runs on Windows XP or Windows 2000 operating systems.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AE12-0CH0 carries an IP65 protection rating, providing protection against dust ingress and low-pressure water jets.
Can this Panel PC communicate directly with Siemens S7 PLCs?
Yes, the Panel PC supports communication with Siemens S7-300 and S7-400 PLCs via Ethernet (TCP/IP, PROFINET) and MPI/PROFIBUS using appropriate communication cards or adapters.
Is the touch screen on this unit replaceable?
Yes, the resistive touch screen assembly can be replaced as a spare part. Recalibration of the touch screen is required after replacement using the built-in calibration utility.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify the internal fuse and backlight inverter board are functioning.
Replace the backlight inverter or the TFT display assembly if the supply voltage is confirmed correct and the unit does not display any image. Check and replace the internal fuse if blown.
Touch screen does not respond or is misaligned
Determine whether the issue is a calibration problem or a hardware failure by attempting to recalibrate via the Windows Control Panel touch screen utility.
Perform a full touch screen recalibration. If the screen remains unresponsive after calibration, inspect the touch controller board connections and replace the touch screen assembly if necessary.
Unit fails to boot or continuously restarts
Check the storage medium (hard disk or CompactFlash) for errors using a disk diagnostic tool. Inspect BIOS settings for correct boot device selection.
Restore the operating system image from a backup. Replace the storage medium if hardware errors are detected. Verify BIOS settings are correctly configured after any battery replacement.
Loss of communication with PLC
Verify the Ethernet or serial cable connections between the Panel PC and the PLC. Check the IP address configuration and communication driver settings in the HMI project.
Replace or reseat the communication cable. Reconfigure the IP address and communication parameters in WinCC or ProTool. Check the PLC-side communication settings for consistency.
System clock resets to default date and time after power cycle
This indicates the CMOS backup battery is depleted and no longer maintaining BIOS settings during power-off periods.
Replace the internal CMOS lithium battery with the correct type. After replacement, reconfigure the BIOS date, time, and any other BIOS settings that were lost.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page