• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AB30-0BH0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AB30-0BH0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AB30-0BH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AB30-0BH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. This unit integrates computing power and a flat-panel display into a single compact housing suitable for front-panel mounting.

    The SIMATIC Panel PC 670 6AV7612-0AB30-0BH0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with standard industrial communication interfaces including USB and Ethernet ports, and is compatible with common industrial communication protocols via expansion options. The unit runs on a Windows-based operating system and is designed for integration with Siemens SIMATIC WinCC and other SCADA/HMI software packages. The robust industrial housing provides protection against dust and moisture ingress suitable for panel installation.

    This Panel PC is widely used in manufacturing automation, process control, and machine tool applications where a combined computing and visualization platform is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and general factory automation. The ability to run standard PC software alongside dedicated HMI applications makes it a flexible solution for complex visualization and data acquisition tasks.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT color LCD
    Touch Technology Resistive touch screen
    Input Voltage 24 V DC
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Communication Interface Ethernet (RJ45), USB, COM ports
    Operating System Windows XP Embedded / Windows 2000
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes and System Events

    Event ID: 1000
    Application error in the HMI runtime software, typically caused by a software exception or crash in the WinCC or ProTool runtime environment.
    Restart the HMI runtime application. Check the Windows event log for detailed error information. Reinstall the runtime software if the error persists.
    Event ID: 1001
    Communication loss between the Panel PC and the connected PLC or controller, indicating a network or configuration fault.
    Check Ethernet or serial cable connections. Verify IP address configuration and PLC communication settings. Ensure the PLC is powered and running.
    Event ID: 100004
    System startup error indicating that the operating system or HMI application failed to load correctly during boot.
    Perform a controlled restart. Check the CompactFlash card or hard disk for errors. Restore the system image from backup if necessary.
    Event ID: 110000
    Screen saver or display timeout event indicating the display has entered power-saving mode.
    Touch the screen or move the mouse to restore the display. Adjust power management settings in the operating system if this occurs unexpectedly.
    Hardware Fault
    Internal hardware component failure detected, such as a failed fan, power supply irregularity, or memory error.
    Check all internal connections and cooling fans. Measure the 24 V DC supply voltage at the input connector. Replace faulty hardware components or return the unit for repair.
    Touch Screen Not Responding
    The resistive touch screen fails to register input, caused by calibration drift, controller failure, or physical damage to the touch surface.
    Recalibrate the touch screen using the calibration utility in the operating system. Check the touch controller connection internally. Replace the touch screen assembly if calibration does not resolve the issue.
    CF Card Read Error
    The system cannot read from the CompactFlash card, which may be caused by a corrupted file system, failed card, or loose connection.
    Reseat the CompactFlash card. Use a PC to check and repair the file system. Replace the CompactFlash card and restore the system image if the card is faulty.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7612-0AB30-0BH0?

    The unit operates on a 24 V DC supply voltage, which is standard for Siemens SIMATIC Panel PC 670 devices.

    What HMI software is compatible with this Panel PC?

    The SIMATIC Panel PC 670 is compatible with Siemens WinCC, WinCC flexible, and ProTool HMI software packages, as well as other standard Windows-based SCADA applications.

    What is the display size and resolution of this unit?

    The 6AV7612-0AB30-0BH0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA).

    What is the front panel protection rating of this Panel PC?

    The front panel of the 6AV7612-0AB30-0BH0 is rated IP65, providing protection against dust and water jets, making it suitable for industrial panel mounting environments.

    Can this Panel PC communicate with Siemens S7 PLCs?

    Yes, the SIMATIC Panel PC 670 can communicate with Siemens S7-300 and S7-400 PLCs via Ethernet using the S7 protocol, as well as through PROFIBUS with an appropriate communication card.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the input connector. Verify that the power LED indicator is illuminated. Inspect the internal display cable connection and the backlight inverter board.

    Ensure the 24 V DC supply is within tolerance. Replace the backlight inverter or CCFL backlight lamp if the display remains dark but the system is otherwise operational. Replace the power supply module if no supply voltage is present internally.

    Touch screen input is inaccurate or unresponsive

    Determine whether the issue is calibration drift or a hardware failure by attempting a touch screen recalibration from the operating system. Check for physical damage or contamination on the touch surface.

    Run the touch screen calibration utility from the Windows control panel or system settings. Clean the touch surface with a soft cloth. If calibration fails repeatedly, replace the resistive touch screen overlay and touch controller.

    Panel PC fails to boot or continuously restarts

    Check the CompactFlash card seating and integrity. Connect an external monitor via the VGA port to determine if the display itself is the fault. Review the Windows event log if the system boots partially.

    Reseat or replace the CompactFlash card. Restore the factory system image using a backup image. If the unit still fails to boot, inspect the mainboard for visible damage and consider replacing the internal computing module.

    Loss of communication with PLC

    Verify the Ethernet cable connection and check the link LED on the Ethernet port. Confirm the IP address configuration on both the Panel PC and the PLC. Use a ping test to check network connectivity.

    Replace the Ethernet cable if faulty. Reconfigure the IP address settings in Windows network settings. Check the PLC communication configuration in the HMI project and reload the project if necessary.

    System clock loses time after power off

    The real-time clock battery on the mainboard may be discharged. This is a common issue on older units that have been in storage or service for extended periods.

    Replace the CMOS battery on the mainboard with the correct replacement type. After replacement, reset the system date and time in the BIOS and operating system settings.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart