The Siemens 6AV7612-0AB30-0BG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. The unit combines a built-in display with a full PC architecture, enabling it to run standard Windows-based SCADA and HMI software alongside industrial control applications.
The SIMATIC Panel PC 670 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and integrates a touch-sensitive screen for operator interaction. It is equipped with an Intel Celeron processor and runs on a 24 V DC supply voltage. The unit provides standard PC interfaces including USB ports, serial COM ports, and an Ethernet interface for network connectivity. An integrated CompactFlash slot is available for data storage, and the fanless design option supports reliable operation in environments where dust and vibration are concerns.
The SIMATIC Panel PC 670 is widely deployed in manufacturing, process automation, and machine tool applications where a full PC platform is required at the operator station. Its rugged industrial enclosure and panel-mount design make it suitable for integration into control cabinets and operator panels on factory floors. Industries such as automotive, food and beverage, chemical processing, and discrete manufacturing commonly use this platform for supervisory control and data acquisition tasks.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT Color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Processor | Intel Celeron |
| Operating System | Windows XP / Windows 2000 (factory configurable) |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM ports) |
| Storage | CompactFlash slot |
| Mounting | Panel mount (front-frame installation) |
| Protection Rating | IP65 (front panel) |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 95% (non-condensing) |
| Certifications | CE, UL |
Common Error Codes and System Events
- Event ID: 1000
- Application error in the HMI runtime software, typically caused by a software fault or incompatible configuration file.
Restart the HMI runtime application. If the fault persists, reinstall the HMI software or restore a known-good configuration backup. - Event ID: 1001
- Communication loss between the Panel PC and the connected PLC or controller.
Check Ethernet or serial cable connections, verify IP address settings, and confirm the PLC is online and reachable. - Event ID: 6008
- Windows system event indicating that a previous shutdown was unexpected, often caused by a power interruption.
Check the 24 V DC power supply for stability and voltage drops. Consider adding a UPS or buffer module to the supply. - Event ID: 7034
- A service terminated unexpectedly, which may affect HMI runtime or communication drivers.
Check Windows Event Viewer for the specific service name. Restart the service manually or configure it to restart automatically on failure. - Event ID: 7036
- A system service has entered a stopped state, potentially interrupting HMI or network functionality.
Identify the stopped service via Windows Event Viewer and restart it. Investigate root cause such as driver conflicts or corrupted installation. - BSOD (Stop Error)
- Windows blue screen error indicating a critical system fault, often related to hardware failure, driver issues, or corrupted system files.
Note the stop code displayed. Check RAM integrity, CompactFlash card health, and driver compatibility. Reinstall the operating system if necessary. - No Boot Device Found
- The Panel PC cannot locate a bootable storage device, typically caused by a failed or corrupted CompactFlash card.
Replace the CompactFlash card with a new one and restore the operating system image using the Siemens recovery media.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AB30-0BG0?
The unit operates on a 24 V DC supply voltage, which is standard for Siemens SIMATIC Panel PC 670 devices.
What operating system does the SIMATIC Panel PC 670 support?
The Panel PC 670 supports Windows XP Professional and Windows 2000, depending on the factory configuration ordered. The specific OS version is determined at the time of order.
What is the front panel protection rating of this Panel PC?
The front panel of the 6AV7612-0AB30-0BG0 carries an IP65 protection rating, making it resistant to dust and water jets when properly panel-mounted.
Can this Panel PC run Siemens WinCC or SIMATIC HMI software?
Yes, the SIMATIC Panel PC 670 is designed to run Siemens WinCC, WinCC flexible, and other SIMATIC HMI visualization software packages under its supported Windows operating system.
What storage medium does the 6AV7612-0AB30-0BG0 use?
The unit uses a CompactFlash card as its primary storage medium, which can be replaced or upgraded and allows for easy OS and application restoration.
Troubleshooting
Display remains blank after power on
Check that the 24 V DC supply voltage is present and within tolerance at the power input connector. Verify that the backlight is not simply dimmed or switched off via software settings.
Restore the 24 V DC supply if absent. If voltage is correct but display remains blank, the backlight inverter or TFT panel may have failed and the display assembly should be replaced.
Touchscreen does not respond or responds inaccurately
Check whether the touch controller is recognized in Windows Device Manager. Determine if the issue is a calibration problem or a hardware fault by testing with a mouse.
Recalibrate the touchscreen using the Windows calibration utility. If calibration does not resolve the issue, check the touch controller ribbon cable connection or replace the touchscreen overlay.
Panel PC fails to boot and shows 'No Boot Device' error
The CompactFlash card may have failed, become corrupted, or is not seated correctly in its slot.
Reseat the CompactFlash card. If the error persists, replace the CompactFlash card and restore the operating system using Siemens recovery media or a verified OS image backup.
Loss of communication with PLC or network
Verify the Ethernet cable connection and check the network adapter status in Windows Device Manager. Ping the PLC IP address from the Panel PC to test connectivity.
Replace the Ethernet cable if faulty. Reconfigure the IP address settings if they have been lost. Update or reinstall the Ethernet adapter driver if the adapter is not recognized.
Panel PC runs slowly or HMI application freezes
Check CPU and memory utilization in Windows Task Manager. Inspect the CompactFlash card for available free space and check for background processes consuming resources.
Close unnecessary background applications and disable non-essential startup programs. If the CompactFlash card is nearly full, archive or delete old log files. Consider replacing the CompactFlash card with a higher-capacity unit if storage is insufficient.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page