• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AB30-0BF0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AB30-0BF0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AB30-0BF0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AB30-0BF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. The unit integrates a flat-panel display with a built-in computing platform, offering a compact all-in-one solution for process visualization and control.

    The SIMATIC Panel PC 670 (6AV7612-0AB30-0BF0) features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 64,000 colors. It is equipped with an Intel Celeron processor and runs on Microsoft Windows operating systems, supporting SIMATIC WinCC and other Siemens HMI software packages. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), enabling integration with SIMATIC S7 PLCs and other automation controllers. The front panel meets IP65 protection rating, making it suitable for installation in control cabinet doors exposed to dust and water spray.

    The SIMATIC Panel PC 670 is widely used in the automotive, food and beverage, pharmaceutical, and machine-building industries for process visualization, SCADA applications, and operator control stations. Its robust industrial design and compatibility with Siemens SIMATIC software make it a reliable choice for machine-level HMI installations. The panel PC format allows direct mounting into control cabinet cutouts, reducing installation space and wiring complexity compared to separate PC and display solutions.

    Technical Specifications

    Display Size 12.1 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Colors 64,000 colors
    Display Type TFT LCD
    Processor Intel Celeron
    Operating System Windows XP / Windows 2000
    Input/Operating Voltage 24 V DC
    IP/Protection Rating IP65 (front panel)
    Communication Interface Ethernet RJ45, USB, RS-232/RS-422/RS-485
    Mounting Panel mounting (flush mount)
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)

    Common Error Codes & System Events

    Event ID: 100
    System startup error — the operating system failed to initialize correctly during boot.
    Check the hard disk or CompactFlash card for integrity. Verify that the OS installation is intact and re-image if necessary.
    Event ID: 1001
    Application crash or unexpected software termination detected by Windows error reporting.
    Review the Windows event log for the faulting application. Reinstall or update the HMI software (e.g., WinCC) and apply relevant patches.
    Event ID: 7000
    A system service failed to start during Windows boot sequence.
    Check the Windows Services configuration. Ensure all required SIMATIC and system services are set to automatic start and are not corrupted.
    Event ID: 7036
    A service entered a stopped or running state unexpectedly, indicating instability in a system service.
    Identify the affected service in the Windows event log and restart it. If recurring, reinstall the associated software component.
    Hardware Watchdog Timeout
    The hardware watchdog timer was not reset in time, indicating a system hang or software freeze.
    Investigate the running application for deadlocks or excessive CPU load. Ensure WinCC runtime and background processes are functioning correctly.
    Temperature Warning
    Internal temperature of the Panel PC has exceeded the recommended operating threshold.
    Check ambient temperature and ensure adequate ventilation around the unit. Clean any dust filters and verify that the cooling fan (if present) is operational.
    Drive Error
    The internal storage device (hard disk or CompactFlash) is reporting read/write errors or is not detected.
    Replace the internal storage medium. Restore the OS and HMI application from a backup image. Consider using a CompactFlash card for improved reliability.
    Network Connection Lost
    The Ethernet interface has lost communication with the connected PLC or network infrastructure.
    Check Ethernet cable connections and switch/hub status. Verify IP address configuration and ensure the SIMATIC communication driver is running correctly.

    Frequently Asked Questions

    What display size and resolution does the 6AV7612-0AB30-0BF0 have?

    The unit features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 64,000 colors.

    What is the supply voltage for the SIMATIC Panel PC 670 (6AV7612-0AB30-0BF0)?

    The Panel PC operates on a 24 V DC supply voltage, which is standard for industrial control cabinet installations.

    Which HMI software is compatible with this Panel PC?

    The 6AV7612-0AB30-0BF0 is compatible with Siemens SIMATIC WinCC and other PC-based HMI and SCADA software packages that run on Windows XP or Windows 2000.

    What is the front panel protection rating of this unit?

    The front panel of the SIMATIC Panel PC 670 meets IP65 protection, providing resistance against dust ingress and water jets, making it suitable for control cabinet door mounting.

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), enabling connectivity to SIMATIC S7 PLCs and other automation devices.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the power input connector. Check whether the power LED or any system indicator is active to determine if the unit is receiving power.

    Verify and restore the 24 V DC supply. If power is confirmed but the display remains blank, check the display backlight inverter or replace the backlight assembly. A failed internal power supply board may also require replacement.

    Panel PC fails to boot or gets stuck at the Windows startup screen

    Attempt to boot from an external medium. Check the BIOS settings for the correct boot device sequence. Listen for hard disk activity to determine if the storage device is being accessed.

    Replace the internal hard disk or CompactFlash card and restore the operating system and HMI application from a backup image. Verify BIOS settings are correctly configured after replacement.

    Touchscreen does not respond or registers incorrect touch positions

    Check whether the touchscreen controller is recognized in Windows Device Manager. Verify that the touchscreen calibration utility has been run and that the calibration data is saved correctly.

    Recalibrate the touchscreen using the Siemens or Windows calibration tool. If the issue persists, check the touchscreen controller cable connections internally. Replace the touchscreen overlay or controller board if hardware damage is confirmed.

    Loss of communication with SIMATIC S7 PLC

    Verify the Ethernet cable connection and check the network switch or hub. Confirm the IP address configuration of both the Panel PC and the PLC. Check whether the SIMATIC communication driver (e.g., S7-1200/S7-300 Ethernet driver) is running in Windows.

    Restore the correct IP address settings and ensure the communication driver is installed and running. Replace the Ethernet cable if damaged. If the onboard Ethernet port is faulty, consider using a PCIe or PCMCIA Ethernet adapter as a replacement.

    System clock resets to incorrect date and time after power cycle

    This typically indicates that the internal CMOS battery on the motherboard is depleted and no longer retaining BIOS settings.

    Replace the internal CMOS coin cell battery (typically CR2032) on the Panel PC motherboard. After replacement, re-enter the correct BIOS settings including date, time, and boot sequence.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart