Siemens 6AV7612-0AB30-0BE0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AB30-0BE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated industrial PC platform, offering a compact and rugged all-in-one solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7612-0AB30-0BE0) features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 256,000 colors, providing clear visualization of process data. The unit is equipped with a resistive touchscreen for operator input and runs on a Windows-based operating system, supporting SIMATIC WinCC and other Siemens HMI software packages. It provides multiple communication interfaces including Ethernet (RJ45) and standard PC ports (USB, serial), enabling integration with SIMATIC S7 PLCs and other automation systems via PROFIBUS or Industrial Ethernet. The fanless or fan-cooled design and industrial-grade components ensure reliable operation in harsh industrial conditions.
The SIMATIC Panel PC 670 is widely used in manufacturing, process industries, automotive production, and machine building applications where a full PC-based HMI platform is required. Its compatibility with standard Windows software and Siemens SIMATIC software makes it suitable for complex visualization tasks, data logging, and recipe management. The robust panel-mount housing and wide operating temperature range make it appropriate for installation in control cabinets and operator panels on the factory floor.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Colors | 256,000 colors |
| Display Type | TFT LCD |
| Touch Technology | Resistive touchscreen |
| Input/Operating Voltage | 24 V DC |
| Communication Interface | Ethernet (RJ45), USB, RS-232 serial |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| IP/Protection Rating | IP65 (front panel) |
| Mounting | Panel mount |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup error — Windows failed to start correctly, possibly due to corrupted system files or failed boot device.
Check hard disk or CompactFlash card integrity. Restore or reinstall the operating system image using the Siemens recovery medium. - Event ID: 1001
- Application crash or unexpected software termination of the HMI runtime (e.g. WinCC flexible Runtime).
Review Windows Event Viewer logs for the faulting application. Reinstall or repair the HMI runtime software. Check for software compatibility issues. - BIOS POST Error
- Hardware self-test failure during power-on, indicating a memory, CPU, or hardware component fault.
Reseat RAM modules and internal connectors. If the error persists, replace the defective hardware component or return the unit for repair. - WinCC Runtime Error
- WinCC flexible or WinCC Runtime fails to start or crashes during operation, often due to a corrupted project file or insufficient resources.
Reload the HMI project from the engineering station. Check available disk space and RAM. Reinstall the runtime software if necessary. - Network Connection Lost
- Ethernet communication to the PLC or network is interrupted, causing loss of process data on the HMI display.
Check Ethernet cable connections and switch/hub status. Verify IP address configuration and PLC communication settings in the HMI project. - Touchscreen Calibration Error
- Touchscreen input is misaligned or unresponsive, indicating a calibration drift or touchscreen controller fault.
Perform touchscreen recalibration via the Windows control panel or Siemens SIMATIC ProSave tool. If unresponsive, check the touchscreen controller connection internally. - Temperature Warning
- Internal temperature of the Panel PC has exceeded the recommended operating threshold, risking hardware damage.
Check ambient temperature and ensure adequate ventilation around the unit. Clean air filters if present. Verify that the cooling fan (if equipped) is operational.
Frequently Asked Questions
What operating system does the SIMATIC Panel PC 670 (6AV7612-0AB30-0BE0) run?
The SIMATIC Panel PC 670 runs a Windows-based operating system, typically Windows XP Professional or Windows XP Embedded, depending on the specific configuration ordered. It supports Siemens SIMATIC WinCC and WinCC flexible HMI software.
What is the display size and resolution of this Panel PC?
The 6AV7612-0AB30-0BE0 features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 256,000 colors.
What communication interfaces are available on this unit?
The unit provides an Ethernet (RJ45) interface for Industrial Ethernet communication, USB ports, and RS-232 serial ports. PROFIBUS connectivity can be added via an optional expansion card.
Is this Panel PC compatible with Siemens S7 PLCs?
Yes, the SIMATIC Panel PC 670 is designed to communicate with Siemens SIMATIC S7-300 and S7-400 PLCs via Industrial Ethernet or PROFIBUS, using standard Siemens communication drivers within the WinCC software environment.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AB30-0BE0 carries an IP65 protection rating, making it resistant to dust and water jets when correctly installed in a panel cutout with the supplied seal.
Troubleshooting
Display remains blank after power on
Check that 24 V DC supply voltage is present at the power connector. Verify that the power LED indicator is illuminated. Measure supply voltage with a multimeter at the input terminals.
Ensure the 24 V DC supply is within tolerance. If the supply is correct but the display remains blank, check internal fuse and backlight inverter. The backlight or display assembly may require replacement.
Touchscreen does not respond to input or input is inaccurate
Determine whether the issue is a calibration drift or a hardware failure by attempting recalibration. Check if the touchscreen controller is recognized in Windows Device Manager.
Recalibrate the touchscreen using the Windows control panel calibration tool or Siemens SIMATIC ProSave. If the touchscreen remains unresponsive after recalibration, replace the touchscreen overlay or the internal touchscreen controller board.
HMI runtime software fails to start or crashes repeatedly
Review the Windows Event Viewer application log for error messages related to the WinCC or WinCC flexible runtime. Check available free disk space and RAM utilization.
Free up disk space if below minimum requirements. Reinstall the HMI runtime software from the original installation media. Reload the HMI project from the engineering PC using SIMATIC ProSave or WinCC flexible.
No communication with PLC over Ethernet
Verify the Ethernet cable connection and check the link LED on the RJ45 port. Use the Windows ping command to test network connectivity to the PLC IP address. Check IP address and subnet mask configuration on both devices.
Replace the Ethernet cable if faulty. Correct the IP address configuration on the Panel PC or PLC. Verify that the correct communication driver and connection parameters are configured in the HMI project.
Panel PC runs slowly or becomes unresponsive during operation
Check CPU and RAM utilization in Windows Task Manager. Identify any background processes consuming excessive resources. Check the hard disk or CompactFlash card for errors using Windows disk check tools.
Terminate unnecessary background applications and services. Run a disk check and defragmentation if using a hard disk drive. If the storage medium is failing, replace the hard disk or CompactFlash card and restore the system image.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page