• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AB30-0BJ0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AB30-0BJ0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AB30-0BJ0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AB30-0BJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial-grade panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. The unit integrates a flat-panel display with an embedded PC platform, providing a compact all-in-one solution for process visualization and control.

    The SIMATIC Panel PC 670 6AV7612-0AB30-0BJ0 features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 256 colors. It is equipped with an Intel Celeron processor and runs on a Windows-based operating system, supporting SIMATIC WinCC and other Siemens HMI software packages. The unit provides standard PC interfaces including USB, serial (RS-232), parallel, and Ethernet ports, enabling flexible integration into existing automation networks. It is designed for panel mounting and operates on a 24 V DC supply voltage.

    The SIMATIC Panel PC 670 is widely used in manufacturing, process industries, and machine building where a robust, integrated PC-based HMI solution is required. Its industrial-hardened design makes it suitable for installation in control cabinets and operator panels in environments subject to vibration, dust, and temperature variation. Typical applications include SCADA visualization, machine control interfaces, and process monitoring in sectors such as automotive, food and beverage, and chemical processing.

    Technical Specifications

    Display Size 12.1 inch
    Display Type TFT LCD
    Display Resolution 800 x 600 pixels (SVGA)
    Display Colors 256 colors
    Input Voltage 24 V DC
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    IP Rating (Front) IP65
    Mounting Panel mounting
    Communication Interface Ethernet (RJ45), RS-232, USB, Parallel
    Operating System Windows XP / Windows 2000
    Series SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    System startup failure — the Panel PC fails to complete the boot sequence, often due to a corrupted operating system or failed storage medium.
    Check the CompactFlash card or hard disk for errors. Restore or reinstall the operating system image using the Siemens recovery medium.
    Event ID: 1000
    Application crash — the HMI runtime application (e.g. WinCC flexible Runtime) has terminated unexpectedly.
    Review the Windows Event Viewer for application error details. Reinstall or repair the HMI runtime software. Check for software compatibility issues.
    Event ID: 6008
    Unexpected shutdown — the system was not shut down cleanly, indicating a possible power interruption or system hang.
    Verify the 24 V DC power supply stability. Check for loose connections at the power connector. Inspect the UPS configuration if applicable.
    Communication Error
    Loss of communication between the Panel PC and the connected PLC or automation controller via Ethernet or serial interface.
    Verify network cable connections and IP address configuration. Check firewall settings and ensure the correct communication driver is installed and configured in WinCC.
    Display No Signal
    The display backlight is active but no image is shown, indicating a failure in the graphics subsystem or display connection.
    Reseat internal display cable connections. Check graphics driver installation. If the fault persists, the display or internal graphics hardware may require replacement.
    Watchdog Timeout
    The hardware watchdog timer has triggered a system reset due to the operating system or application becoming unresponsive.
    Investigate CPU load and memory usage. Check for runaway processes in Task Manager. Update or reinstall the HMI application and ensure the watchdog is correctly configured.
    Fan Failure Warning
    The system cooling fan has stopped or is operating below the minimum required speed, risking thermal shutdown.
    Inspect and clean the fan and ventilation slots. Replace the cooling fan if it is not operating correctly. Ensure ambient temperature is within the specified operating range.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7612-0AB30-0BJ0?

    The SIMATIC Panel PC 670 6AV7612-0AB30-0BJ0 operates on a 24 V DC supply voltage. Ensure the power supply is stable and within the specified tolerance range.

    What HMI software is compatible with this Panel PC?

    The unit is compatible with Siemens SIMATIC WinCC, WinCC flexible, and other Windows-based HMI and SCADA software packages. The operating system is Windows XP or Windows 2000.

    What is the display size and resolution of this Panel PC?

    The 6AV7612-0AB30-0BJ0 features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA).

    What is the IP protection rating of this Panel PC?

    The front panel of the SIMATIC Panel PC 670 achieves an IP65 protection rating, making it resistant to dust and water jets when correctly installed in a panel cutout.

    Can the operating system or application software be restored on this unit?

    Yes, the operating system and HMI software can be restored using a Siemens-supplied recovery medium, typically via a USB drive or CD-ROM. It is recommended to create a backup image of the CompactFlash card or hard disk before deployment.

    Troubleshooting

    Panel PC does not power on after 24 V DC is applied

    Measure the 24 V DC supply voltage at the power connector terminals. Check for blown internal fuses and verify the power supply unit output is within tolerance.

    Replace any blown fuses with the correct rating. If the power supply voltage is correct but the unit does not start, the internal power supply board may require replacement or professional repair.

    Display is blank but the system appears to be running (HDD activity, fan running)

    Check the display backlight by observing the screen at an angle with a torch. Verify the display cable connection internally. Test with an external monitor if a VGA output is available.

    Replace the display backlight inverter or the TFT display panel. If an external monitor shows output correctly, the fault is isolated to the display assembly.

    Touchscreen does not respond or responds inaccurately

    Check the touchscreen controller driver in Device Manager. Attempt a touchscreen recalibration using the Siemens or Windows calibration utility. Inspect the touchscreen overlay for physical damage.

    Recalibrate the touchscreen via the control panel utility. If calibration does not resolve the issue, reinstall the touchscreen driver or replace the touchscreen overlay and controller.

    Loss of communication with PLC over Ethernet

    Verify the Ethernet cable and switch/hub connections. Ping the PLC IP address from the Panel PC command prompt. Check the WinCC communication driver configuration and PLC connection settings.

    Correct any IP address conflicts or misconfigured subnet settings. Replace the Ethernet cable if faulty. Reinstall the communication driver if the connection cannot be established after network verification.

    System runs slowly or HMI application freezes intermittently

    Check CPU and RAM usage in Windows Task Manager. Inspect the CompactFlash card or hard disk for errors using disk diagnostic tools. Check for excessive background processes consuming resources.

    Remove unnecessary startup programs and background services. Replace the CompactFlash card or hard disk if errors are detected. Consider increasing RAM if the hardware configuration supports it.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart