Siemens 6AV7612-0AA30-0CE0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AA30-0CE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a flat-panel display with a full PC platform, offering a compact and robust solution for process visualization and machine control.
The SIMATIC Panel PC 670 (6AV7612-0AA30-0CE0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports 65,536 colors. It is equipped with an Intel Celeron processor and runs on a Windows-based operating system, providing compatibility with standard SCADA and HMI software packages such as WinCC. The unit offers multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), and is designed for front-panel mounting with an IP65 protection rating on the front face.
The SIMATIC Panel PC 670 is widely used in the manufacturing, automotive, food and beverage, and chemical processing industries. It is typically deployed as an operator station on production lines, packaging machines, and process control systems where a full PC platform is required alongside robust industrial construction. Its compatibility with Siemens SIMATIC software and standard industrial communication protocols makes it well suited for integration into existing SIMATIC automation architectures.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Colors | 65,536 colors |
| Display Type | TFT LCD |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 65 W |
| IP Protection Rating (Front) | IP65 |
| Communication Interface | Ethernet (RJ45), USB, RS-232, RS-422/RS-485 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Mounting | Panel mounting (front flush) |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to load correctly during boot.
Check the hard disk or CompactFlash card for integrity. Reinstall or restore the OS image if corrupted. - Event ID: 200
- Hardware watchdog timeout — the system did not respond within the watchdog monitoring interval.
Check CPU load and running processes. Reduce background tasks or adjust watchdog timeout settings in BIOS. - Event ID: 300
- Fan failure detected — the internal cooling fan has stopped or is operating below the minimum speed threshold.
Inspect and clean the fan. Replace the fan unit if it is mechanically faulty to prevent thermal shutdown. - Event ID: 400
- Temperature warning — internal temperature has exceeded the upper warning threshold.
Check ambient temperature and ventilation around the panel. Clean air filters and ensure the cooling fan is operational. - Event ID: 500
- Battery low warning — the CMOS backup battery voltage is below the minimum level.
Replace the internal CMOS lithium battery (CR2032 or equivalent) to prevent loss of BIOS settings and real-time clock data. - Event ID: 600
- Ethernet communication fault — the network interface is not detecting a valid link or is reporting errors.
Check Ethernet cable connections and switch/hub port status. Verify IP configuration and network settings within the OS. - Event ID: 700
- USB device error — a connected USB peripheral is not recognized or has caused a driver fault.
Disconnect and reconnect the USB device. Update or reinstall the device driver. Avoid using non-industrial USB peripherals.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AA30-0CE0?
The SIMATIC Panel PC 670 (6AV7612-0AA30-0CE0) operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.
What is the display size and resolution of this Panel PC?
This unit features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports 65,536 colors.
What operating system does the 6AV7612-0AA30-0CE0 support?
The SIMATIC Panel PC 670 supports Windows-based operating systems, typically Windows XP Professional or Windows XP Embedded, enabling compatibility with standard SCADA and HMI software including Siemens WinCC.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AA30-0CE0 carries an IP65 protection rating, making it suitable for environments where dust and water spray may be present.
Is this Panel PC compatible with Siemens WinCC software?
Yes, the SIMATIC Panel PC 670 is fully compatible with Siemens WinCC and other SIMATIC HMI software packages, as it runs a standard Windows-based PC platform.
Troubleshooting
Display remains blank after power on
Check that 24 V DC is present at the power supply connector. Verify the display backlight is not failed by checking for faint image under strong light.
If supply voltage is correct but display is blank, replace the backlight inverter or the TFT display panel. If no voltage is present, inspect the power supply and wiring.
Panel PC does not boot or shows OS loading error
Attempt to boot from an external USB device to determine if the internal storage (hard disk or CompactFlash) has failed. Check BIOS for detected storage devices.
Replace the internal hard disk or CompactFlash card and restore the OS image using the Siemens recovery media or a backup image.
Touchscreen does not respond or is misaligned
Check if the touchscreen controller is recognized in Device Manager. Attempt a touchscreen recalibration using the Siemens touchscreen calibration utility.
Recalibrate the touchscreen via the control panel utility. If the touchscreen remains unresponsive, replace the touchscreen overlay or the touchscreen controller board.
Unit overheats and shuts down unexpectedly
Monitor internal temperature via BIOS or system monitoring software. Inspect the cooling fan for operation and check air vents for blockage.
Clean all air vents and filters. Ensure ambient temperature is within the 0 to 50 °C operating range. Replace the cooling fan if it is not spinning or is running slowly.
Ethernet communication is not working
Check the RJ45 connector and cable for physical damage. Verify link LEDs on the Ethernet port and the connected switch. Check IP settings within the operating system.
Replace the Ethernet cable if damaged. Reconfigure the IP address settings if incorrect. If the NIC is faulty, update the network driver or replace the internal network interface card.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page