Siemens 6AV7612-0AA30-0CF0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AA30-0CF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a flat-panel display with a full PC architecture, combining operator panel functionality with the computing power of an industrial PC.
The SIMATIC Panel PC 670 (6AV7612-0AA30-0CF0) features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports 65,536 colors. It is equipped with an Intel Celeron processor and runs on Microsoft Windows operating systems, providing a standard PC environment for SCADA and HMI software such as Siemens WinCC. The unit includes multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), and is designed for front-panel mounting with an IP65 protection rating on the front face. Onboard memory and storage options support reliable operation of visualization applications.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool industries where a robust, panel-mounted PC with integrated display is required. Its fanless or low-noise design variants make it suitable for environments where dust and contamination are concerns. The unit is commonly deployed in control cabinets and operator stations in automotive, food and beverage, chemical, and general industrial manufacturing facilities.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Colors | 65,536 colors |
| Display Type | TFT LCD |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 80 W |
| Front Protection Rating | IP65 |
| Rear Protection Rating | IP20 |
| Communication Interface | Ethernet RJ45, USB, RS-232 (COM ports) |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Mounting | Front panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to boot correctly or a critical system component is unavailable.
Check hard disk or CompactFlash card integrity. Verify OS installation and boot configuration in BIOS. - Event ID: 1000
- Application fault — the HMI or SCADA application (e.g. WinCC) has crashed or terminated unexpectedly.
Review Windows Event Viewer logs for the faulting module. Reinstall or repair the HMI application if necessary. - Event ID: 7034
- A service terminated unexpectedly — a critical Windows service required by the HMI application stopped running.
Check Windows Services configuration. Restart the affected service and configure it for automatic restart on failure. - BIOS POST Error
- Power-On Self-Test failure detected during startup, indicating a hardware fault such as missing RAM or failed peripheral.
Reseat RAM modules and internal cards. Disconnect non-essential peripherals and retry. Replace faulty hardware components. - Watchdog Timeout
- The hardware watchdog timer has triggered a system reset because the operating system or application became unresponsive.
Investigate software hang causes. Check CPU load and memory usage. Update or reconfigure the watchdog timeout settings in BIOS or application. - Temperature Warning
- Internal system temperature has exceeded the defined threshold, risking hardware damage or system shutdown.
Check ambient temperature and ventilation around the panel. Clean air vents and filters. Verify cooling fan operation if applicable. - Hard Disk / Storage Fault
- The internal hard disk drive or CompactFlash storage device is reporting errors or is not detected.
Run disk diagnostics. Replace the hard disk or CompactFlash card with a compatible unit and restore the OS and application image. - Ethernet Link Down
- The Ethernet interface has lost its network connection or the link cannot be established.
Check Ethernet cable and switch port. Verify network adapter settings in Windows Device Manager. Replace cable or network switch port if faulty.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AA30-0CF0?
The SIMATIC Panel PC 670 (6AV7612-0AA30-0CF0) operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.
What display size and resolution does this Panel PC have?
This unit features a 12.1-inch TFT LCD display with a resolution of 800 x 600 pixels (SVGA) and 65,536 colors.
What operating system does the SIMATIC Panel PC 670 support?
The Panel PC 670 supports Microsoft Windows operating systems, typically Windows XP Professional or Windows 2000, depending on the configuration ordered. It provides a standard PC environment compatible with Siemens WinCC and other SCADA software.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AA30-0CF0 carries an IP65 protection rating, making it resistant to dust and water jets, suitable for industrial front-panel mounting.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), USB ports, and RS-232 serial interfaces (COM ports), enabling connectivity to PLCs, networks, and peripheral devices.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector. Verify that the supply is within tolerance and that the power LED or system indicators show activity.
If supply voltage is correct but display remains blank, check internal display cable connections and the backlight inverter. Replace the backlight or LCD panel assembly if the inverter or backlight lamp has failed.
System fails to boot or gets stuck at BIOS/POST screen
Inspect the internal storage device (hard disk or CompactFlash card) for errors. Enter BIOS setup to confirm the boot device is detected and correctly configured.
Replace the hard disk or CompactFlash card with a compatible unit and restore the operating system and HMI application from a backup image. Reseat RAM modules if POST reports memory errors.
Touchscreen does not respond or is inaccurate
Check if the touchscreen controller is recognized in Windows Device Manager. Determine whether the issue is a hardware failure or a calibration problem.
Recalibrate the touchscreen using the Siemens or Windows touchscreen calibration utility. If calibration does not resolve the issue, inspect the touchscreen overlay connection and replace the touchscreen assembly if damaged.
HMI application (WinCC) crashes repeatedly
Review the Windows Event Viewer application log for error codes and faulting module names. Check available RAM and CPU utilization during operation.
Ensure the correct version of WinCC and all required service packs are installed. Free up system resources by disabling unnecessary startup programs. Reinstall the HMI application if corruption is suspected.
Ethernet communication to PLC is lost intermittently
Check the Ethernet cable and switch port for physical faults. Monitor the network adapter status in Windows Device Manager and review the IP configuration.
Replace the Ethernet cable and verify switch port settings. Update the network adapter driver if available. Configure the adapter to a fixed speed and duplex setting to avoid auto-negotiation issues.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page