• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AA30-0BJ0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AA30-0BJ0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AA30-0BJ0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AA30-0BJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a display, computing hardware, and industrial-grade I/O into a single compact panel form factor suitable for control cabinet front-panel installation.

    The SIMATIC Panel PC 670 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch technology for operator input. It is powered by an Intel Celeron processor and runs Microsoft Windows XP Professional or Windows XP Embedded, supporting SIMATIC WinCC and other SCADA/HMI software packages. The unit provides standard PC interfaces including USB ports, a serial COM port, an Ethernet interface (RJ45), and a PS/2 port for keyboard and mouse connectivity. It is designed for 24 V DC supply voltage and is built to meet industrial environmental requirements including vibration and shock resistance.

    The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a full PC-based HMI platform is required. Its panel-mount design makes it suitable for integration into control cabinets and operator stations in industries such as automotive, food and beverage, chemical processing, and discrete manufacturing. The combination of standard PC architecture with industrial-grade construction allows it to run complex visualization, data logging, and process control applications reliably in harsh industrial environments.

    Technical Specifications

    Display Size 12.1 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT Color LCD
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    Processor Intel Celeron
    Operating System Windows XP Professional / Windows XP Embedded
    Communication Interface Ethernet (RJ45), USB, RS-232 (COM), PS/2
    Mounting Panel mounting (front-panel installation)
    Protection Rating IP65 (front panel)
    Operating Temperature 0 °C to 45 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Series/Product Family SIMATIC Panel PC 670

    Common Error Codes & System Events

    Event ID: 1000
    Application error on startup — the HMI or SCADA application has encountered a fatal exception during initialization.
    Check Windows Event Viewer for detailed error logs. Reinstall or repair the HMI software (e.g., WinCC). Verify that all required runtime licenses are present.
    Event ID: 7026
    A boot-start or system-start driver failed to load, indicating a hardware driver issue.
    Boot into Safe Mode and check Device Manager for driver conflicts. Reinstall the appropriate hardware drivers for the Panel PC hardware.
    Event ID: 6008
    Unexpected system shutdown recorded — the previous system shutdown was unexpected, possibly due to power loss or system crash.
    Check the 24 V DC power supply for stability and correct voltage. Inspect power connections and consider adding a UPS or buffer module to prevent power interruptions.
    Event ID: 51
    An error was detected on device during a paging operation, indicating a failing storage device (hard disk or CompactFlash).
    Run a disk diagnostic utility (e.g., chkdsk). Back up data immediately and replace the hard disk or CompactFlash storage medium if errors persist.
    BIOS POST Error
    The Panel PC fails to complete the Power-On Self-Test, indicating a hardware fault such as failed RAM or corrupted BIOS.
    Reseat RAM modules. If the BIOS is corrupted, contact Siemens service for BIOS recovery or replace the mainboard.
    WinCC Runtime Error
    WinCC runtime fails to start or crashes, often due to a corrupted project file or database inconsistency.
    Restore the WinCC project from a backup. Run the WinCC consistency check tool and repair any database errors. Ensure the correct WinCC version is installed for the project.
    Network Connection Lost
    The Ethernet interface loses connection to the PLC or SCADA server, causing communication failure in the HMI application.
    Check Ethernet cable and switch/hub connections. Verify IP address configuration in Windows Network Settings. Check PLC communication driver settings in the HMI project.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7612-0AA30-0BJ0?

    The SIMATIC Panel PC 670 (6AV7612-0AA30-0BJ0) operates on a 24 V DC supply voltage, which is standard for industrial panel PCs in this series.

    What operating system does this Panel PC run?

    This unit supports Microsoft Windows XP Professional or Windows XP Embedded as its operating system, and is compatible with SIMATIC WinCC and other Siemens HMI software packages.

    What is the display size and resolution of this unit?

    The 6AV7612-0AA30-0BJ0 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and a resistive touchscreen for operator input.

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45), USB ports, RS-232 serial (COM port), and PS/2 interfaces for keyboard and mouse connectivity.

    What is the front panel protection rating of this device?

    The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it resistant to dust and water jets, suitable for industrial control cabinet installation.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the power connector. Verify that the backlight is not simply dimmed or switched off via software settings. Listen for fan or hard disk activity to determine if the PC is booting.

    If the PC is booting but the display is blank, check display cable connections internally. If the backlight has failed, the CCFL backlight or inverter board may need replacement. If there is no activity at all, inspect the internal fuse and verify the power supply output voltage.

    Touchscreen does not respond or is inaccurate

    Determine whether the issue is a complete lack of response or positional inaccuracy. Check if the touchscreen driver is loaded correctly in Device Manager under Windows.

    Recalibrate the touchscreen using the calibration utility in the Windows Control Panel or Siemens touchscreen driver software. If the touchscreen is unresponsive, check the internal ribbon cable connection between the touch panel and the controller board. Replace the touch overlay if the surface is damaged.

    Panel PC fails to boot and shows BIOS error or no POST

    Attempt to boot and observe any error messages on screen. Check if the hard disk or CompactFlash card is detected in the BIOS setup menu. Reseat RAM modules and check for any loose internal connections.

    If the storage device is not detected, replace the hard disk or CompactFlash card and reinstall the operating system and HMI software. If RAM is faulty, replace with compatible industrial-grade memory. Contact Siemens technical support if the mainboard is suspected to be faulty.

    HMI application loses communication with the PLC

    Check the Ethernet link indicator LEDs on the RJ45 port. Ping the PLC IP address from the Windows command prompt to verify network connectivity. Review the WinCC diagnostic logs for communication error messages.

    Verify the Ethernet cable and network switch are functioning correctly. Confirm that the IP address, subnet mask, and gateway settings in Windows match the network configuration. Check the PLC communication driver configuration in the WinCC project and ensure the PLC is online and reachable.

    System runs slowly or HMI application freezes

    Open Windows Task Manager to check CPU and RAM usage. Check the hard disk for available free space and fragmentation. Review the Windows Event Viewer for application or system errors that may indicate software conflicts.

    Free up disk space by removing unnecessary files and defragmenting the hard disk. Increase virtual memory if RAM is insufficient. If the hard disk is failing (indicated by slow read/write speeds or Event ID 51 errors), replace it with a new drive or a CompactFlash-to-IDE adapter for improved reliability.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart