Siemens 6AV7612-0AA30-0BH0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AA30-0BH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a display, computing hardware, and industrial-grade I/O into a single compact panel-mount enclosure.
The SIMATIC Panel PC 670 features a 15-inch TFT display with a resolution of 1024 x 768 pixels and a resistive touchscreen interface. It is powered by an Intel Celeron processor and runs Microsoft Windows XP or Windows XP Embedded, supporting SIMATIC WinCC and other Siemens HMI software packages. The unit provides standard PC interfaces including USB, Ethernet (RJ45), serial COM ports, and a PCI slot for expansion, along with a CompactFlash slot for additional storage. The front panel meets IP65 protection rating, making it suitable for use in environments where dust and water ingress are a concern.
The SIMATIC Panel PC 670 is widely deployed in manufacturing, process automation, and machine tool applications where a full PC-based HMI platform is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and packaging, where operators require rich visualization, data logging, and integration with SCADA or MES systems. Its panel-mount design and industrial-grade construction allow direct integration into control cabinet doors or operator stations.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 pixels |
| Display Type | TFT LCD |
| Display Colors | 16.7 million colors |
| Touch Technology | Resistive touchscreen |
| Processor | Intel Celeron |
| Operating System | Windows XP / Windows XP Embedded |
| Input/Operating Voltage | 24 V DC |
| Communication Interface | Ethernet RJ45, USB, RS-232 (COM ports) |
| Expansion | 1 x PCI slot |
| Storage Interface | CompactFlash slot |
| IP/Protection Rating | IP65 (front panel) |
| Mounting | Panel mount |
| Operating Temperature | 0 °C to 45 °C |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to boot correctly, possibly due to a corrupted boot partition or failed storage device.
Check the CompactFlash card or hard disk for errors. Re-image the storage device with the correct OS image if necessary. - Event ID: 200
- Hardware watchdog timeout — the watchdog timer triggered a system reset due to an application or OS hang.
Investigate the running application for deadlocks or excessive CPU load. Ensure WinCC or the HMI application is correctly configured and not overloading the processor. - Event ID: 300
- Fan failure detected — the internal cooling fan has stopped or is running below the minimum speed threshold.
Inspect and clean the fan. Replace the fan unit if it is not operating within specification to prevent thermal shutdown. - Event ID: 400
- Temperature warning — internal temperature has exceeded the warning threshold.
Check ambient temperature and ensure adequate ventilation around the panel. Clean air filters and verify fan operation. - Event ID: 500
- Battery low warning — the CMOS/RTC backup battery voltage is below the minimum threshold.
Replace the internal CMOS battery (typically CR2032 or equivalent) to prevent loss of BIOS settings and real-time clock data. - Event ID: 600
- Ethernet communication failure — the network interface is not detecting a link or is unable to communicate with the network.
Check the Ethernet cable and switch port. Verify IP address configuration and network settings within the operating system. - Event ID: 700
- USB device error — a connected USB device is not recognized or has caused a driver fault.
Disconnect and reconnect the USB device. Update or reinstall the USB device driver. Avoid using non-industrial USB devices. - Event ID: 800
- Application crash or WinCC runtime error — the HMI visualization software has terminated unexpectedly.
Review the WinCC diagnostic log for the specific error. Reinstall or repair the WinCC runtime installation if the issue persists.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AA30-0BH0?
The SIMATIC Panel PC 670 6AV7612-0AA30-0BH0 operates on a 24 V DC supply voltage, which is standard for industrial panel PCs in this series.
What HMI software is compatible with this Panel PC?
This unit is compatible with Siemens SIMATIC WinCC, WinCC flexible, and other PC-based HMI and SCADA software packages that run on Windows XP or Windows XP Embedded.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AA30-0BH0 carries an IP65 protection rating, providing protection against dust ingress and low-pressure water jets.
Does this Panel PC support expansion cards?
Yes, the SIMATIC Panel PC 670 includes one PCI expansion slot, allowing the installation of additional interface cards such as PROFIBUS or other fieldbus communication cards.
What communication interfaces are available on this unit?
The unit provides Ethernet (RJ45), USB ports, and RS-232 serial COM ports as standard interfaces, enabling connectivity to PLCs, networks, and peripheral devices.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify that the power LED is illuminated. Measure voltage at the internal power supply output rails.
Ensure the 24 V DC supply is within tolerance. If the supply is correct but the display remains blank, the internal power supply board or the display backlight inverter may have failed and should be replaced.
Touchscreen does not respond or is inaccurate
Verify that the touchscreen driver is correctly installed in the operating system. Check Device Manager for any driver errors related to the touch controller.
Recalibrate the touchscreen using the calibration utility in the Windows control panel or SIMATIC software. If calibration fails, the resistive touch overlay or touch controller board may need replacement.
System fails to boot or continuously restarts
Check the CompactFlash card or hard disk for physical damage or corruption. Attempt to boot from an external USB device to isolate whether the fault is with the storage device or the motherboard.
Re-image the storage device with the correct OS and software image. If the system still fails to boot, the motherboard or internal power supply may be faulty and require replacement.
Ethernet communication is not working
Verify the Ethernet cable connection and check the link LED on the RJ45 port. Open Device Manager to confirm the network adapter is recognized and has no errors.
Replace the Ethernet cable and check the network switch port. Reinstall the network adapter driver if it shows an error. If the port is physically damaged, an expansion card can be used as an alternative.
BIOS settings reset after power cycle
This typically indicates that the CMOS backup battery has discharged. The BIOS will revert to default settings and the real-time clock will lose its time on each power cycle.
Replace the internal CMOS battery with the correct type as specified in the service documentation. After replacement, re-enter the correct BIOS settings and synchronize the system clock.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page