• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AA20-0AE0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AA20-0AE0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AA20-0AE0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AA20-0AE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface applications, combining computing power with a rugged, integrated display unit. This product serves as a full-featured industrial PC in a compact panel form factor, suitable for use as an operator station or visualization platform in automation environments.

    The SIMATIC Panel PC 670 (6AV7612-0AA20-0AE0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and is equipped with a touch-sensitive screen for operator interaction. It is based on an x86-compatible processor architecture and supports standard PC operating systems such as Windows XP or Windows 2000. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), enabling integration with PLCs, SCADA systems, and plant networks. It is designed for panel mounting with an IP65-rated front face, protecting against dust and water ingress in industrial environments.

    The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine tool industries where a robust, panel-integrated PC-based HMI is required. It is suitable for applications demanding visualization, data logging, and process control on a single platform, such as packaging machinery, automotive assembly lines, and chemical processing plants. The IP65 front protection and industrial-grade components make it appropriate for environments with elevated levels of dust, moisture, and vibration.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT color LCD
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    Power Consumption Approx. 60 W
    Front Protection Rating IP65
    Rear Protection Rating IP20
    Communication Interface Ethernet (RJ45), USB, RS-232 (COM ports)
    Operating System Windows XP / Windows 2000
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    Mounting Panel mounting
    Certifications CE, UL
    Series SIMATIC Panel PC 670

    Common Error Codes & System Events

    Event ID: 100
    Operating system startup failure or boot error detected during POST sequence
    Check hard disk or CompactFlash card integrity. Verify OS installation and boot configuration. Replace storage media if corrupted.
    Event ID: 200
    Watchdog timeout triggered — application software stopped responding
    Restart the Panel PC. Check the running application for software faults or infinite loops. Update or reinstall the HMI application software.
    Event ID: 300
    Fan failure or thermal warning — internal temperature exceeding threshold
    Check and clean ventilation slots. Verify fan operation. Ensure ambient temperature is within the 0–45 °C operating range.
    Event ID: 400
    Power supply voltage out of range — 24 V DC supply below or above tolerance
    Measure the 24 V DC supply at the input connector. Ensure supply is within 20.4–28.8 V DC. Check cable connections and power supply unit.
    Event ID: 500
    Touchscreen calibration error or touch input not responding correctly
    Recalibrate the touchscreen using the Siemens calibration utility in the control panel. Clean the screen surface. Replace touchscreen if calibration fails repeatedly.
    Event ID: 600
    Ethernet communication failure — network interface not detected or link down
    Check Ethernet cable and network switch connection. Verify IP address configuration. Reinstall network adapter drivers if the interface is not detected by the OS.
    Event ID: 700
    Hard disk or storage media read/write error
    Run a disk check utility (chkdsk) on the storage device. Back up data and replace the hard disk or CompactFlash card if errors persist.
    Event ID: 800
    BIOS battery low warning — real-time clock losing time after power off
    Replace the internal CMOS battery (CR2032 or equivalent). Re-enter BIOS settings and set the correct date and time after replacement.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7612-0AA20-0AE0?

    The unit operates on a 24 V DC supply voltage, typically within a tolerance range of 20.4 V DC to 28.8 V DC.

    What operating systems are supported by the SIMATIC Panel PC 670?

    The Panel PC 670 supports Windows XP Professional and Windows 2000, which were the standard industrial OS options for this product generation.

    What is the front panel protection rating of this Panel PC?

    The front panel of the 6AV7612-0AA20-0AE0 carries an IP65 protection rating, making it resistant to dust and water jets. The rear enclosure is rated IP20.

    Can this Panel PC be used with Siemens WinCC or SIMATIC HMI software?

    Yes, the SIMATIC Panel PC 670 is compatible with Siemens WinCC, WinCC flexible, and other SIMATIC HMI visualization software packages running under the supported Windows operating systems.

    What communication interfaces are available on this unit?

    The unit provides Ethernet (RJ45), multiple USB ports, and RS-232 serial interfaces, allowing connection to PLCs, barcode scanners, printers, and plant networks.

    Troubleshooting

    Panel PC does not boot and display remains blank after power on

    Check the 24 V DC supply voltage at the input connector. Verify that the power LED indicator is active. Listen for POST beep codes that may indicate a hardware fault.

    Ensure the 24 V DC supply is within tolerance. If power is confirmed, reseat the RAM modules and storage media. If the unit still does not boot, the motherboard or power supply board may require replacement.

    Touchscreen does not respond or registers incorrect touch positions

    Attempt to operate the unit using a connected USB mouse to confirm the OS is running. Check if the touchscreen driver is loaded correctly in Device Manager.

    Recalibrate the touchscreen via the Siemens calibration tool in the Windows control panel. If calibration fails, clean the screen surface thoroughly. Replace the touchscreen assembly if the fault persists.

    Unit frequently restarts or watchdog resets occur during operation

    Check the application software for crashes or unhandled exceptions. Review the Windows event log for application or system errors. Monitor the CPU temperature to rule out thermal shutdown.

    Update or reinstall the HMI application software. Ensure ventilation slots are unobstructed and the internal fan is operational. If overheating is confirmed, reduce ambient temperature or improve panel enclosure ventilation.

    Ethernet communication is lost or the network interface is not recognized

    Check the Ethernet cable and verify link LEDs on the RJ45 port. Open Device Manager in Windows to confirm the network adapter is detected without errors.

    Replace the Ethernet cable and verify switch port configuration. Reinstall the network adapter driver if it shows an error in Device Manager. If the onboard NIC is faulty, an external USB-to-Ethernet adapter may be used as a temporary measure.

    Real-time clock loses the correct time and date after each power cycle

    This indicates the internal CMOS battery is depleted. Confirm by entering the BIOS setup and checking if the date and time reset to default values on each boot.

    Replace the internal CMOS lithium battery (typically CR2032). After replacement, re-enter the BIOS to set the correct date, time, and any custom BIOS settings before restarting the OS.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart