Siemens 6AV7612-0AA13-0CF0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7612-0AA13-0CF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial automation environments. This unit integrates a flat-panel display with a built-in computing platform, providing a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7612-0AA13-0CF0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is based on an x86-compatible processor architecture and runs Microsoft Windows operating systems, enabling compatibility with standard SCADA and HMI software such as Siemens WinCC. The unit includes multiple communication interfaces including Ethernet and serial ports, and is built to withstand industrial environments with a front panel protection rating of IP65.
This Panel PC is widely used in manufacturing, process automation, and machine tool industries where a combination of robust hardware and flexible PC-based software is required. Its fanless or low-maintenance design variants make it suitable for environments with dust or particulate contamination. The integration of standard PC interfaces allows engineers to connect peripherals, industrial networks, and enterprise systems directly from the panel.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touch screen |
| Input Voltage | 24 V DC |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Communication Interface | Ethernet (RJ45), RS-232, USB |
| Operating System | Microsoft Windows XP / Windows 2000 |
| Series | SIMATIC Panel PC 670 |
| Mounting | Panel mounting |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify OS installation and boot configuration in BIOS settings. - Event ID: 200
- Hardware watchdog timeout — the system did not respond within the watchdog interval.
Check CPU load and running processes. Restart the Panel PC and investigate software causing system overload. - Event ID: 300
- Fan failure detected (if applicable to variant). Cooling system not operating within specification.
Inspect and clean the fan assembly. Replace the fan module if it is not spinning or is running below rated speed. - Event ID: 400
- Supply voltage out of tolerance. The 24 V DC input voltage has dropped below or exceeded acceptable limits.
Measure the supply voltage at the power connector. Ensure the power supply unit provides a stable 24 V DC within the specified tolerance range. - Event ID: 500
- Touch screen calibration error or touch input not responding correctly.
Recalibrate the touch screen using the Windows control panel touch calibration utility. If the issue persists, inspect the touch controller connection. - Event ID: 600
- Communication interface error on Ethernet or serial port. Loss of network connectivity detected.
Check cable connections and network switch status. Verify IP configuration and driver settings within the operating system. - Event ID: 700
- Storage medium error — read/write failure on hard disk or CompactFlash card.
Run a disk check utility to identify bad sectors. Replace the storage medium if errors persist and restore the OS image from backup.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AA13-0CF0?
The SIMATIC Panel PC 670 (6AV7612-0AA13-0CF0) operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel devices.
What operating system does this Panel PC support?
This unit supports Microsoft Windows XP and Windows 2000, allowing compatibility with standard HMI and SCADA software packages including Siemens WinCC.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AA13-0CF0 carries an IP65 protection rating, making it resistant to dust ingress and water jets, suitable for industrial panel mounting.
What display size and resolution does this Panel PC have?
The unit features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch screen input.
Is this Panel PC compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens WinCC visualization software, as it runs a standard Windows operating system and meets the hardware requirements for WinCC runtime environments.
Troubleshooting
Panel PC does not power on after 24 V DC is applied
Measure the 24 V DC supply voltage at the power input connector to confirm it is within tolerance. Check internal fuses if accessible.
Ensure the power supply is stable and within the 24 V DC specification. Replace any blown internal fuses and verify wiring polarity at the power connector.
Display is blank or shows no image after power on
Check if the system is booting by listening for hard disk activity or observing indicator LEDs. Connect an external monitor via VGA if available to determine if the issue is with the display or the system board.
If the system boots but the display is blank, inspect the display cable connection internally. Replace the backlight inverter or TFT panel if the backlight has failed.
Touch screen input is inaccurate or unresponsive
Attempt to operate the system using a USB mouse to isolate whether the issue is with the touch controller or the software. Check Device Manager in Windows for touch controller errors.
Recalibrate the touch screen through the Windows control panel. If calibration does not resolve the issue, inspect the touch screen ribbon cable connection or replace the touch screen assembly.
System freezes or reboots unexpectedly during operation
Check CPU and system temperature using a monitoring utility. Review Windows event logs for hardware or software errors that occurred prior to the freeze or reboot.
Clean any air vents or filters to improve cooling. Ensure the operating system and drivers are correctly installed. If the issue persists, test the RAM modules and replace the storage medium if disk errors are found.
Ethernet communication is not established
Verify the network cable is connected and the link LED on the Ethernet port is active. Check the IP address configuration in Windows Network Settings.
Replace the network cable if the link LED is not active. Reconfigure the IP address settings to match the network requirements. Update or reinstall the Ethernet adapter driver if the adapter is not recognized in Device Manager.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page