• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AA13-0CE0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AA13-0CE0 SIMATIC Panel PC 670

    € 1.995,00

    Reset
    Clear
    SKU: 6AV7612-0AA13-0CE0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AA13-0CE0 is an industrial Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is a compact, fanless panel-mounted industrial PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. This unit integrates computing power and a flat-panel display into a single rugged housing suitable for direct panel installation.

    The SIMATIC Panel PC 670 (6AV7612-0AA13-0CE0) features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch screen technology for operator input. It is powered by an Intel Celeron processor and runs Microsoft Windows XP or Windows CE depending on configuration, supporting SIMATIC WinCC flexible and other Siemens HMI software packages. The unit provides standard industrial interfaces including USB, RS-232, and Ethernet (RJ45), and is designed for 24 V DC supply voltage. The front panel meets IP65 protection rating, making it resistant to dust and water jets.

    The SIMATIC Panel PC 670 is widely deployed in machine building, automotive manufacturing, food and beverage processing, and general factory automation where a combined PC and HMI solution is required. Its panel-mount design and IP65-rated front face make it suitable for integration into control cabinets and operator stations exposed to industrial environments. The device is compatible with the broader Siemens SIMATIC automation ecosystem, enabling seamless integration with S7 PLCs and PROFIBUS or PROFINET networks.

    Technical Specifications

    Display Size 12.1 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT Color LCD
    Touch Technology Resistive
    Input Voltage 24 V DC
    IP Protection Rating (Front) IP65
    Operating Temperature 0 °C to 45 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 10 % to 90 % (non-condensing)
    Communication Interface Ethernet (RJ45), RS-232, USB
    Processor Intel Celeron
    Operating System Windows XP / Windows CE
    Mounting Panel mounting
    Series SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes and System Events

    Event ID: 100
    System startup failure — the operating system failed to initialize correctly during boot.
    Check the CompactFlash card or hard disk for errors. Reinstall or replace the storage medium and reload the OS image.
    Event ID: 1000
    Application crash — the HMI runtime software (e.g. WinCC flexible Runtime) has terminated unexpectedly.
    Check the application event log for details. Reinstall the HMI runtime software and verify project integrity.
    BIOS POST Error
    Hardware self-test failure detected during power-on self-test, indicating a memory or hardware fault.
    Reseat RAM modules if accessible. If the error persists, replace the defective hardware component or return the unit for repair.
    Watchdog Timeout
    The system watchdog timer has expired, indicating the operating system or application has become unresponsive.
    Restart the Panel PC. Check for software loops or resource overloads in the HMI application. Update or reinstall the runtime software.
    Touch Screen Not Responding
    The resistive touch screen is not registering input or is responding inaccurately.
    Recalibrate the touch screen via the Windows control panel or SIMATIC settings. Clean the screen surface and check the touch controller connection internally.
    Ethernet Link Failure
    No network connection is detected on the Ethernet interface, preventing communication with PLCs or SCADA systems.
    Check the Ethernet cable and switch port. Verify IP address configuration and network settings in Windows. Replace the cable or network adapter if faulty.
    Storage Medium Error
    Read/write error detected on the CompactFlash card or internal hard disk drive.
    Back up project data immediately. Run a disk check utility. Replace the CompactFlash card or HDD and restore the OS and HMI project from backup.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7612-0AA13-0CE0?

    The unit operates on 24 V DC supply voltage, which is standard for Siemens SIMATIC Panel PC 670 devices.

    What is the display size and resolution of this Panel PC?

    The 6AV7612-0AA13-0CE0 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA).

    Is this Panel PC compatible with Siemens WinCC flexible?

    Yes, the SIMATIC Panel PC 670 supports SIMATIC WinCC flexible Runtime as well as other Siemens HMI visualization software packages.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7612-0AA13-0CE0 carries an IP65 protection rating, providing protection against dust ingress and water jets.

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45), RS-232 serial, and USB interfaces, enabling connectivity to PLCs, networks, and peripheral devices.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the power connector. Check the internal fuse and verify the power supply unit is functioning correctly.

    Restore correct supply voltage within the 24 V DC specification. Replace the internal fuse if blown. If the backlight is faulty, replace the display backlight inverter or the display assembly.

    Touch screen input is inaccurate or unresponsive

    Determine whether the issue is a calibration problem or a hardware fault by attempting recalibration via the Windows control panel. Inspect the screen surface for damage or contamination.

    Recalibrate the touch screen using the SIMATIC or Windows touch calibration tool. Clean the screen with a soft cloth. If the touch controller has failed, the touch screen assembly may need replacement.

    Panel PC fails to boot or hangs at startup

    Observe the boot sequence for BIOS POST errors or Windows startup errors. Check the CompactFlash card or hard disk for physical damage or file system corruption.

    Run a disk check utility on the storage medium. If the OS is corrupted, reinstall the operating system and HMI runtime from a backup image. Replace the storage medium if it is physically faulty.

    Loss of communication with S7 PLC over Ethernet

    Verify the Ethernet cable connection and check the link LED on the RJ45 port. Confirm the IP address settings in Windows match the network configuration.

    Replace the Ethernet cable if damaged. Reconfigure the IP address and subnet mask as required. Check firewall settings and ensure the correct PROFINET or TCP/IP driver is installed and active.

    HMI runtime software crashes repeatedly

    Review the Windows application event log for error codes and crash details. Check available storage space on the system drive and verify RAM is functioning correctly.

    Free up disk space if the storage medium is nearly full. Reinstall the WinCC flexible Runtime software and reload the HMI project. If hardware faults are suspected, run a memory diagnostic and replace faulty components.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart