Siemens 6AV7611-0AB30-0AJ0 Mobile Panel 170
€ 1.770,00
The Siemens 6AV7611-0AB30-0AJ0 is a Mobile Panel 170, part of the SIMATIC Mobile Panel series from Siemens. It is a portable human-machine interface (HMI) device designed for flexible, handheld operation and monitoring of industrial machinery and processes. The unit connects to SIMATIC S7 PLCs and other compatible controllers, enabling operators to move freely around a machine or production area while maintaining full control.
The Mobile Panel 170 features a 5.7-inch STN color display with a resolution of 320 x 240 pixels, providing clear visualization of process data and machine states. It is equipped with a PROFIBUS DP interface for communication with SIMATIC S7 controllers and supports configuration via SIMATIC WinCC flexible or ProTool software. The panel includes a 3-position enabling switch and an emergency stop button, both of which are safety-critical elements for safe handheld operation. An integrated membrane keypad with function keys allows direct operator input without requiring a touchscreen.
The Mobile Panel 170 is widely used in manufacturing, automotive assembly, machine tool, and packaging industries where operators need to move along a machine during setup, commissioning, or maintenance tasks. Its handheld form factor and integrated safety devices make it particularly suitable for applications requiring close proximity to moving machinery, such as robot cell tending, press line operation, and conveyor system adjustment. The robust housing and industrial-grade construction allow it to withstand the demands of harsh shop floor environments.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Resolution | 320 x 240 pixels |
| Display Type | STN color |
| Display Colors | 256 colors |
| Input/Operating Voltage | 24 V DC |
| Communication Interface | PROFIBUS DP |
| Safety Features | 3-position enabling switch, Emergency stop button |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP/Protection Rating | IP65 (front) |
| Series/Product Family | SIMATIC Mobile Panel 170 |
| Configuration Software | SIMATIC WinCC flexible, ProTool |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 10000
- Communication error on PROFIBUS DP interface. The panel has lost connection to the PLC or the connection was interrupted.
Check PROFIBUS cable connections and termination resistors. Verify the PROFIBUS address settings on both the panel and the PLC. Inspect the cable for damage. - Event ID: 10001
- Configuration error. The project loaded on the panel does not match the connected controller or the configuration is corrupt.
Reload the correct project configuration using WinCC flexible or ProTool. Verify the PLC type and PROFIBUS address match the project settings. - Event ID: 20000
- Enabling switch not in enabling position. The 3-position enabling switch is not held in the middle (enable) position.
Ensure the operator is holding the enabling switch in the correct middle position. If the switch is held but the error persists, test the enabling switch contacts for continuity and replace if faulty. - Event ID: 20001
- Emergency stop activated. The integrated emergency stop button on the Mobile Panel has been pressed.
Identify and resolve the cause of the emergency stop activation. Unlock the emergency stop button by rotating it, then reset the safety circuit at the controller before resuming operation. - Event ID: 30000
- Internal device error. A hardware fault has been detected within the Mobile Panel.
Cycle power to the device. If the error persists, note the full event ID details and contact Siemens technical support or arrange for unit repair and inspection. - Event ID: 40000
- Project download error. Transfer of the configuration project to the panel was interrupted or failed.
Check the transfer cable connection and PC communication settings. Retry the download using WinCC flexible or ProTool. Ensure sufficient memory is available on the panel. - Event ID: 50000
- Power supply undervoltage. The 24 V DC supply voltage has dropped below the minimum operating threshold.
Measure the supply voltage at the panel connector. Ensure the power supply is rated for the panel load and that cable runs are not causing excessive voltage drop. Replace or adjust the power supply as needed.
Frequently Asked Questions
Which PLC systems is the Mobile Panel 170 (6AV7611-0AB30-0AJ0) compatible with?
The Mobile Panel 170 communicates via PROFIBUS DP and is primarily compatible with Siemens SIMATIC S7-300 and S7-400 PLCs. It can also connect to other PROFIBUS DP-capable controllers supported by the WinCC flexible or ProTool configuration software.
What configuration software is required for the Mobile Panel 170?
The panel is configured using Siemens SIMATIC WinCC flexible or the older ProTool software. Projects are created on a PC and then downloaded to the panel via the appropriate transfer cable.
Does the Mobile Panel 170 include safety-rated inputs?
Yes, the panel features an integrated 3-position enabling switch and an emergency stop button. These are safety-critical devices intended to be wired into the machine safety circuit to enable safe handheld operation near moving machinery.
What is the supply voltage requirement for this panel?
The Mobile Panel 170 requires a 24 V DC power supply, which is typically provided through the connection cable from the machine control cabinet.
What is the IP protection rating of the Mobile Panel 170?
The front face of the Mobile Panel 170 is rated to IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for typical industrial shop floor environments.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the panel connection cable. Verify that the cable and connector are undamaged and fully seated. Measure voltage at the supply terminals inside the control cabinet.
Restore the 24 V DC supply to the correct level. Replace a damaged connection cable. If the supply voltage is correct and the display remains blank, the internal power supply or display unit may be faulty and the panel should be sent for repair.
PROFIBUS communication fault displayed on panel
Inspect the PROFIBUS cable for physical damage, loose connectors, or missing termination resistors at both ends of the bus segment. Verify the PROFIBUS node address set on the panel matches the address configured in the PLC project.
Repair or replace damaged PROFIBUS cable. Ensure termination resistors are correctly installed at the bus endpoints. Correct the PROFIBUS address on the panel or in the PLC configuration to ensure they match.
Enabling switch does not enable machine motion
Test the enabling switch contacts using a multimeter in continuity mode across all three positions. Check the wiring from the panel connector to the machine safety relay or safety PLC input.
Replace the enabling switch if contacts are found to be open or intermittent in the enable position. Repair any wiring faults between the panel connector and the safety circuit. Verify the safety relay or safety PLC is correctly configured to accept the enabling switch signal.
Emergency stop button cannot be reset
Check whether the emergency stop mushroom head is fully released by rotating it in the direction indicated. Inspect the wiring from the E-stop contacts to the safety relay or safety controller for continuity.
Rotate and release the emergency stop button fully. If the safety circuit does not reset, check for wiring faults or a faulty E-stop contact block and replace as necessary. Ensure the machine safety logic requires a deliberate reset action after E-stop release.
Project download fails or transfer to panel is incomplete
Verify the transfer cable is correctly connected between the PC and the panel transfer port. Check that the correct COM port or USB adapter is selected in WinCC flexible or ProTool. Confirm the panel is in transfer mode.
Use a known-good transfer cable. Select the correct interface settings in the configuration software. Place the panel in transfer mode via the panel loader menu. If errors persist, perform a factory reset of the panel and retry the download.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page