Siemens 6AV7611-0AB30-0BE0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AB30-0BE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a flat-panel display with a full PC platform, enabling both operator control and data processing within a single ruggedized enclosure.
The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation for intuitive operator interaction. It is built around an x86-compatible processor architecture and runs Microsoft Windows operating systems, supporting SIMATIC WinCC and other SCADA/HMI software packages. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), and is designed for front-panel mounting with an IP65 protection rating on the front face. Onboard memory and storage options allow for local data logging and application hosting.
The SIMATIC Panel PC 670 is widely deployed in manufacturing automation, process control, and machine tool applications where a combined visualization and computing platform is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and general factory automation. Its robust construction and compatibility with the SIMATIC software ecosystem make it a practical choice for integrating into existing Siemens-based control architectures.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touch screen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Communication Interface | Ethernet RJ45, USB, RS-232 |
| Operating System | Microsoft Windows XP / Windows 2000 |
| Mounting | Panel mounting (front flush) |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup failure — the Panel PC fails to complete the boot sequence, often due to corrupted OS or failed storage device.
Check the hard disk or CompactFlash card for errors. Attempt OS recovery or reinstall the operating system. - Event ID: 200
- Communication interface error — loss of connection on the Ethernet or serial interface to the PLC or SCADA system.
Verify network cable connections and interface settings. Check IP configuration and ensure the connected controller is online. - Event ID: 300
- Touch screen calibration error — touch input is misaligned or unresponsive.
Perform touch screen recalibration via the Windows control panel or SIMATIC HMI configuration tool. Clean the touch surface and check for damage. - Event ID: 400
- Fan failure or overtemperature warning — internal cooling fan has stopped or ambient temperature exceeds the rated limit.
Inspect and clean the cooling fan. Ensure ambient temperature is within 0–45 °C. Replace the fan if it has failed. - Event ID: 500
- Hard disk or storage device error — read/write failure detected on the internal storage medium.
Back up data immediately if possible. Run disk diagnostics and replace the hard disk or CompactFlash card as required. - Event ID: 600
- Power supply undervoltage — the 24 V DC supply voltage has dropped below the minimum operating threshold.
Measure the supply voltage at the power connector. Ensure the power source maintains a stable 24 V DC within specified tolerances. - Event ID: 700
- WinCC Runtime connection lost — the HMI application has lost communication with the configured data source or PLC tag server.
Check PLC program status and communication settings in WinCC. Restart the WinCC Runtime application and verify tag connections.
Frequently Asked Questions
What operating systems are supported by the SIMATIC Panel PC 670 (6AV7611-0AB30-0BE0)?
The SIMATIC Panel PC 670 supports Microsoft Windows XP Professional and Windows 2000, which are compatible with SIMATIC WinCC and other Siemens HMI software packages.
What is the supply voltage for this Panel PC?
The 6AV7611-0AB30-0BE0 operates on a 24 V DC supply voltage, which is standard for SIMATIC Panel PC 670 units.
Is the SIMATIC Panel PC 670 compatible with SIMATIC WinCC?
Yes, the Panel PC 670 is designed to run SIMATIC WinCC and other SIMATIC HMI visualization software, making it directly compatible with Siemens S7 PLC families.
What is the front panel protection rating of this unit?
The front panel of the 6AV7611-0AB30-0BE0 carries an IP65 protection rating, providing protection against dust ingress and low-pressure water jets.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), USB ports, and RS-232 serial interfaces, enabling connectivity to PLCs, network infrastructure, and peripheral devices.
Troubleshooting
Panel PC does not boot or display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify that the internal storage device (hard disk or CompactFlash) is properly seated and recognized in BIOS.
Reseat the storage device and power connectors. If the storage medium is faulty, replace it and reinstall the operating system and HMI application software.
Touch screen input is inaccurate or unresponsive
Determine whether the issue is hardware (damaged touch surface or controller) or software (miscalibration). Test touch response in the Windows environment outside of the HMI application.
Recalibrate the touch screen using the Windows control panel calibration utility. If the touch surface is physically damaged or the touch controller has failed, the touch panel assembly must be replaced.
Loss of communication between Panel PC and PLC
Check Ethernet cable integrity and verify the IP address configuration on both the Panel PC and the PLC. Confirm that the WinCC communication driver is running and correctly configured.
Replace the Ethernet cable if damaged. Correct any IP address conflicts or subnet mismatches. Restart the WinCC Runtime and re-establish the communication channel.
Overtemperature warning or system shutdown due to heat
Check the ambient temperature around the Panel PC enclosure and inspect the cooling fan for blockage or failure. Verify that ventilation clearances around the unit are maintained.
Clean dust from the fan and ventilation slots. Ensure ambient temperature does not exceed 45 °C. Replace the cooling fan if it is not operating correctly.
HMI application crashes or freezes during operation
Check available RAM and storage space on the system. Review Windows Event Viewer logs for application errors or memory faults. Determine if the issue is reproducible under specific conditions.
Free up disk space and close unnecessary background applications. Update or reinstall the WinCC Runtime software. If hardware memory is faulty, replace the RAM module.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page