Siemens 6AV7611-0AB30-0AH0 Mobile Panel 170
€ 1.770,00
The Siemens 6AV7611-0AB30-0AH0 is a Mobile Panel 170, part of the SIMATIC Mobile Panel series from Siemens. This handheld operator panel is designed for flexible, mobile human-machine interface applications where operators need to move freely around a machine or installation. It provides a compact, rugged touchscreen interface for direct interaction with automation systems in the field.
The Mobile Panel 170 features a 5.7-inch STN color display with a resolution of 320 x 240 pixels (QVGA), offering clear visualization of process data and operator screens. It connects to the control system via a coiled cable with a standardized connector, supporting MPI and PROFIBUS DP communication interfaces. The panel includes configurable function keys, an enabling button (three-position safety switch) for safe manual operation, and an emergency stop button, making it suitable for safety-relevant applications. It is configured using Siemens WinCC flexible engineering software.
The Mobile Panel 170 is widely used in manufacturing, automotive, and machine-building industries where operators must perform setup, commissioning, or maintenance tasks while moving around large machines or production lines. Its integrated enabling switch and emergency stop comply with machine safety requirements, making it suitable for use in direct proximity to moving machine parts. The panel is compatible with Siemens S7-300 and S7-400 PLC families as well as other SIMATIC controllers.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Resolution | 320 x 240 pixels (QVGA) |
| Display Type | STN color LCD |
| Display Colors | 256 colors |
| Touch Technology | Resistive touchscreen |
| Input/Operating Voltage | 24 V DC |
| Communication Interface | MPI, PROFIBUS DP |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP/Protection Rating | IP65 (front), IP54 (rear) |
| Safety Features | Three-position enabling button, Emergency stop button |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC Mobile Panel 170 |
| Engineering Software | WinCC flexible |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the Mobile Panel and the connected PLC or controller. The panel cannot establish or maintain a connection.
Check the cable connection and connector integrity. Verify MPI or PROFIBUS DP address settings on both the panel and PLC. Ensure the PLC is in RUN mode and the bus termination is correct. - Event ID: 10001
- Connection to the configured PLC address has been lost during operation.
Inspect the coiled cable for damage. Check bus configuration and address assignments. Restart the panel and attempt to re-establish communication. - Event ID: 20000
- Project download error. The project could not be transferred to the Mobile Panel successfully.
Verify the transfer cable and PC interface settings in WinCC flexible. Ensure the panel is in transfer mode and that the correct communication port is selected on the engineering PC. - Event ID: 30000
- Internal device error or hardware fault detected on the Mobile Panel.
Perform a power cycle. If the fault persists, check for physical damage to the unit. The panel may require service or replacement of internal components. - Event ID: 40000
- Enabling button not in valid position during operation. The three-position enabling switch was released or fully pressed during a motion command.
Ensure the operator holds the enabling button in the middle (enabled) position during manual operation. Review machine safety logic and enabling switch wiring. - Event ID: 50000
- Emergency stop activated. The integrated E-stop button on the Mobile Panel has been pressed.
Identify and resolve the cause of the emergency stop. Reset the E-stop button by rotating and releasing it, then acknowledge the fault in the control system before resuming operation. - Event ID: 60000
- Configuration or project file missing or corrupted on the panel.
Re-download the project from WinCC flexible to the Mobile Panel. Verify project integrity in the engineering software before transfer.
Frequently Asked Questions
Which PLCs are compatible with the Mobile Panel 170 (6AV7611-0AB30-0AH0)?
The Mobile Panel 170 is compatible with Siemens S7-300 and S7-400 PLCs via MPI or PROFIBUS DP. It can also communicate with other SIMATIC controllers that support these interfaces.
What engineering software is required to configure this panel?
The Mobile Panel 170 is configured using Siemens WinCC flexible. Projects are created on a PC and downloaded to the panel via the transfer cable.
Does this panel have an integrated safety enabling switch?
Yes, the 6AV7611-0AB30-0AH0 includes a three-position enabling button and an integrated emergency stop button, making it suitable for safe manual operation near moving machine parts in accordance with machine safety standards.
What is the display size and resolution of the Mobile Panel 170?
The panel features a 5.7-inch STN color display with a resolution of 320 x 240 pixels (QVGA) and supports 256 colors.
What communication interfaces does the Mobile Panel 170 support?
The Mobile Panel 170 supports MPI and PROFIBUS DP communication interfaces, connected via a coiled cable with a standardized multi-pin connector.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the panel connector using a multimeter. Inspect the coiled cable and connector for damage or bent pins.
Ensure the power supply is within the 24 V DC specification. Replace the coiled cable if damaged. If the display remains blank with confirmed power, the internal display or power board may require repair or replacement.
Panel cannot establish communication with the PLC
Verify the MPI or PROFIBUS DP address configured on the panel matches the PLC network settings. Check bus termination resistors at both ends of the network. Inspect the cable connector for damage.
Correct any address mismatches in the WinCC flexible project settings. Ensure proper bus termination is applied. Replace the coiled cable if continuity testing reveals a fault.
Touchscreen does not respond or responds inaccurately
Check for physical damage or contamination on the touchscreen surface. Attempt a touchscreen recalibration if accessible through the panel service menu.
Clean the touchscreen surface with a soft, dry cloth. Perform touchscreen calibration via the panel's system settings. If the issue persists, the touchscreen overlay may need to be replaced.
Enabling button does not allow machine motion when pressed
Test the enabling switch output signal at the machine control cabinet terminal. Check the wiring from the Mobile Panel connector to the safety relay or PLC safety input.
Verify correct wiring of the enabling switch contacts according to the Mobile Panel 170 wiring diagram. Replace the enabling switch assembly if the contact does not close in the middle position. Ensure the safety circuit is correctly configured in the machine controller.
Project cannot be downloaded to the panel
Confirm the panel is set to transfer mode. Check the PC interface settings in WinCC flexible and verify the correct COM port or USB-to-MPI adapter is selected.
Switch the panel to transfer mode via the start screen. Reinstall or reconfigure the PC adapter driver if necessary. Verify the project has no compilation errors in WinCC flexible before attempting the transfer again.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page