Siemens 6AV7611-0AB30-0AG0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AB30-0AG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated industrial PC platform, providing a compact all-in-one solution for process visualization and control.
The SIMATIC Panel PC 670 6AV7611-0AB30-0AG0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is powered by an industrial-grade processor and runs Microsoft Windows operating systems, supporting SIMATIC WinCC and other Siemens HMI software packages. The unit provides multiple communication interfaces including Ethernet (RJ45) and serial ports, and is built to withstand industrial environments with a front panel protection rating of IP65.
This Panel PC is widely used in manufacturing, process automation, and machine tool industries where a robust, integrated PC-based HMI solution is required. Its panel-mount design makes it suitable for integration into control cabinets and operator panels on production lines, packaging machinery, and process control systems. The combination of a standard PC architecture with industrial-grade construction allows engineers to run custom SCADA and visualization software alongside standard automation software.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| Front Panel Protection Rating | IP65 |
| Rear Protection Rating | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interfaces | Ethernet (RJ45), RS-232, USB |
| Mounting | Panel mount |
| Certifications | CE, UL |
| Series | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to load correctly during boot.
Check hard disk or CompactFlash card integrity. Verify OS installation and boot configuration. Replace storage media if corrupted. - Event ID: 200
- Watchdog timeout — the system watchdog detected a software hang or process failure.
Restart the Panel PC. Check for software conflicts or runaway processes. Update or reinstall the HMI application software. - Event ID: 300
- Temperature warning — internal temperature has exceeded the recommended operating threshold.
Check ambient temperature and ventilation around the unit. Clean air vents and ensure the cooling fan (if present) is operational. Reduce thermal load. - Event ID: 400
- Power supply undervoltage — the 24 V DC supply voltage has dropped below the permissible minimum.
Measure the supply voltage at the power connector. Ensure the power supply unit provides a stable 24 V DC within specified tolerance. Replace power supply if faulty. - Event ID: 500
- Touchscreen calibration error — the touchscreen is not responding correctly or is out of calibration.
Run the touchscreen calibration utility from the Windows Control Panel or SIMATIC configuration tool. If calibration fails, inspect the touchscreen controller hardware. - Event ID: 600
- Communication interface error — loss of communication on Ethernet or serial interface.
Check cable connections and network configuration. Verify IP address settings and firewall rules. Replace cable or network adapter if hardware fault is confirmed. - Event ID: 700
- Storage media error — read/write error detected on the hard disk or CompactFlash card.
Run a disk check utility. Back up data immediately. Replace the storage media and restore the system image if errors persist.
Frequently Asked Questions
What operating system does the SIMATIC Panel PC 670 6AV7611-0AB30-0AG0 support?
This Panel PC supports Microsoft Windows XP Professional and Windows 2000 Professional, and is compatible with SIMATIC WinCC and other Siemens HMI visualization software.
What is the supply voltage for this Panel PC?
The unit operates on 24 V DC supply voltage, which is standard for industrial panel-mounted devices in automation environments.
What is the front panel protection rating of this unit?
The front panel of the 6AV7611-0AB30-0AG0 carries an IP65 protection rating, making it resistant to dust and water jets, suitable for panel-mount installation in industrial enclosures.
Can this Panel PC communicate with Siemens S7 PLCs?
Yes, the Panel PC supports Ethernet-based communication and can connect to Siemens S7-300 and S7-400 PLCs using PROFINET or Industrial Ethernet with appropriate SIMATIC software drivers.
What display size and resolution does this unit have?
The unit features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA), with resistive touchscreen input.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify that the power LED indicator is active. Inspect internal fuses and the backlight inverter board.
Restore correct supply voltage if out of range. Replace the backlight inverter or CCFL backlight lamp if the display is powered but dark. Replace the internal power supply module if no voltage is present.
Touchscreen does not respond or responds inaccurately
Attempt to operate the unit using an external USB mouse to determine if the issue is isolated to the touchscreen. Check Device Manager in Windows for touchscreen controller errors.
Recalibrate the touchscreen using the Windows calibration utility. If calibration does not resolve the issue, inspect the touchscreen ribbon cable connection and replace the touchscreen assembly if damaged.
Panel PC fails to boot or repeatedly restarts
Check the storage media (hard disk or CompactFlash card) for errors using a bootable diagnostic tool. Inspect the Windows Event Log for critical errors if the system partially boots.
Replace the storage media and restore the system image from a backup. Ensure the BIOS boot order is correctly configured. If the unit still fails to boot, inspect the mainboard for hardware faults.
Loss of communication with PLC or SCADA system
Verify Ethernet cable connection and check the network adapter status in Windows Device Manager. Ping the PLC IP address from the Panel PC to test network connectivity.
Replace the Ethernet cable if faulty. Reconfigure the IP address settings if there is an address conflict. Reinstall the network adapter driver or replace the Ethernet interface card if the hardware is defective.
System clock resets to incorrect date and time after power cycle
This typically indicates a depleted CMOS battery on the mainboard. Confirm by powering off the unit for several hours and checking if the clock resets again upon restart.
Replace the CMOS coin cell battery (typically CR2032) on the Panel PC mainboard. After replacement, set the correct date and time in the BIOS and save the settings.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page