Siemens 6AV7285-6KA00-0AA0 SIMATIC IPC277D
€ 743,00
The Siemens 6AV7285-6KA00-0AA0 is a Panel PC belonging to the SIMATIC IPC277D series, manufactured by Siemens as part of its industrial computing portfolio. This unit is a 15-inch multi-touch panel PC designed for demanding industrial environments, combining HMI functionality with PC-based computing power in a single compact device. It is built to operate reliably in harsh industrial conditions and integrates seamlessly into Siemens automation architectures.
The IPC277D features a 15-inch widescreen TFT display with a projected capacitive (PCT) multi-touch interface, supporting up to 5 simultaneous touch points for intuitive operator interaction. The unit is equipped with an Intel Atom processor, onboard DDR3 RAM, and solid-state or CFast storage options, providing robust computing performance without moving parts. Communication interfaces include multiple USB ports, Ethernet (RJ45), and optional PROFINET connectivity, while the front panel achieves IP65 protection rating for resistance to dust and water ingress.
The SIMATIC IPC277D is widely used in machine building, automotive manufacturing, food and beverage processing, and pharmaceutical production environments. Its fanless design and sealed front panel make it suitable for applications requiring high hygiene standards or exposure to coolants and cleaning agents. The device is compatible with standard Windows operating systems and Siemens WinCC and WinCC flexible SCADA and HMI software platforms.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Type | TFT widescreen |
| Touch Technology | Projected capacitive (PCT) multi-touch, up to 5 touch points |
| Processor | Intel Atom |
| Operating Voltage | 24 V DC |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Communication Interface | 2x RJ45 Ethernet, 4x USB, 1x DisplayPort |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Mounting | Panel mounting (portrait and landscape) |
| Certifications | CE, UL, cULus |
| Operating System | Windows Embedded Standard 7 / Windows 7 Ultimate |
| Series | SIMATIC IPC277D |
Common Error Codes & System Events
- Event ID: 100
- System startup failure – the operating system failed to initialize correctly during boot.
Check storage medium (CFast/SSD) for integrity. Attempt system restore or reinstall the OS image. - Event ID: 1001
- Application crash or unexpected software termination detected by Windows Error Reporting.
Review Windows Event Viewer logs, update or reinstall the affected HMI application (e.g., WinCC), and check for OS patches. - BIOS POST Error
- Hardware component not detected during Power-On Self-Test, such as missing RAM or storage device.
Reseat RAM modules and storage media. If error persists, replace the faulty hardware component. - Watchdog Timeout
- The system watchdog timer triggered a reset due to software hang or unresponsive application.
Identify and terminate the hanging process. Review application configuration and increase watchdog timeout if appropriate. - Temperature Warning
- Internal temperature has exceeded the defined threshold, risking thermal shutdown.
Check ambient temperature and ventilation around the panel PC. Clean any dust from ventilation areas and verify the installation environment is within specification. - Drive Read/Write Error
- The operating system reported an error accessing the CFast card or SSD storage device.
Back up data immediately. Run disk diagnostics and replace the CFast card or SSD if errors are confirmed. - Network Link Down
- Ethernet interface has lost connection or no link is detected on one or both RJ45 ports.
Check Ethernet cable connections and switch/hub status. Verify network adapter settings in Device Manager and replace cable if faulty.
Frequently Asked Questions
What is the display size and touch technology used in the 6AV7285-6KA00-0AA0?
The unit features a 15-inch TFT widescreen display with projected capacitive (PCT) multi-touch technology, supporting up to 5 simultaneous touch points.
What operating systems are supported by the SIMATIC IPC277D?
The IPC277D supports Windows Embedded Standard 7 and Windows 7 Ultimate. It is compatible with Siemens WinCC and WinCC flexible HMI software.
What is the supply voltage for this panel PC?
The SIMATIC IPC277D operates on a 24 V DC supply voltage.
What is the front panel protection rating of the 6AV7285-6KA00-0AA0?
The front panel of this unit is rated IP65, providing full protection against dust ingress and resistance to water jets.
Can the IPC277D be used with PROFINET?
Yes, the IPC277D supports PROFINET communication via its onboard Ethernet interfaces, making it compatible with Siemens PROFINET-based automation networks.
Troubleshooting
Display remains blank after power on
Measure the 24 V DC supply voltage at the power input connector. Check whether the power LED indicates the unit is receiving power.
Verify and restore correct 24 V DC supply. If power is confirmed but display remains blank, the internal power supply board or display backlight inverter may require replacement.
Touch input not responding or inaccurate
Check whether the touch controller is recognized in Windows Device Manager. Inspect the front glass for physical damage or contamination.
Clean the display surface with a lint-free cloth. Recalibrate the touch screen via the Windows control panel. If the issue persists, the touch controller or front glass assembly may need replacement.
System fails to boot or repeatedly restarts
Attempt to boot into BIOS/UEFI setup to determine if the storage device is detected. Check Windows Event Viewer for critical errors logged before the restart.
Replace the CFast card or SSD with a known-good unit and restore the OS image. If the issue persists, inspect RAM modules and reseat or replace them.
Ethernet communication not established
Check the link LEDs on the RJ45 ports. Verify network cable integrity and switch port configuration. Check Device Manager for driver errors on the network adapter.
Replace the Ethernet cable and verify switch settings. Reinstall network adapter drivers if shown as faulty in Device Manager. If hardware fault is confirmed, the unit may require board-level repair.
Unit overheating or thermal shutdown occurring
Measure ambient temperature at the installation location. Verify that the panel cutout dimensions and clearances meet Siemens installation specifications.
Improve cabinet ventilation or add active cooling. Ensure the panel PC is not installed near heat sources. Verify that the fanless thermal design is not obstructed by incorrect mounting orientation.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27