Siemens 6AV7285-6HN10-0AA0 SIMATIC IPC277D
€ 695,00
The Siemens 6AV7285-6HN10-0AA0 is a Panel PC belonging to the SIMATIC IPC277D series, manufactured by Siemens as part of its industrial computing portfolio. This unit is a 19-inch multi-touch panel PC designed for demanding industrial environments, combining a high-performance computing platform with a robust front panel suitable for direct machine-level operation. It is part of the SIMATIC IPC277D family, which is positioned as a mid-range industrial panel PC for visualization and control tasks.
The IPC277D features a widescreen TFT display with a projected capacitive (PCT) multi-touch interface, supporting multi-finger gesture input for intuitive operator interaction. It is equipped with an Intel Atom processor, DDR3 RAM, and solid-state or CFast storage options, providing reliable performance without rotating media. Communication interfaces typically include multiple USB ports, Ethernet (RJ45) ports, and optional PROFINET connectivity, enabling integration into modern industrial networks. The unit supports Windows Embedded Standard 7 or Windows 7 operating systems and is built to meet IP65 protection at the front panel, making it resistant to dust and water ingress.
The SIMATIC IPC277D is widely deployed in the manufacturing, automotive, food and beverage, and process industries, where a robust operator interface with visualization software such as SIMATIC WinCC or WinCC flexible is required. Its fanless or low-maintenance design makes it suitable for environments where reliability and reduced maintenance intervals are critical. The panel PC is commonly used as a central HMI station on production lines, packaging machines, and process control systems where both visualization and local computing capability are needed.
Technical Specifications
| Display Size | 19 inch |
|---|---|
| Display Type | TFT widescreen LCD |
| Touch Technology | Projected capacitive (PCT) multi-touch |
| Input Voltage | 24 V DC |
| Protection Rating (Front) | IP65 |
| Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to 50 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | 2x RJ45 Ethernet, 4x USB |
| Processor | Intel Atom |
| Operating System | Windows Embedded Standard 7 / Windows 7 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC IPC277D |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST.
Check storage media (CFast/SSD) for integrity. Verify OS installation. Replace storage media if corrupted. - Event ID: 1000
- Application crash or unexpected software termination reported by Windows Event Log.
Review Windows Event Viewer for details. Reinstall the affected application or update drivers. Check for memory errors using diagnostics. - Event ID: 6008
- Unexpected system shutdown recorded by Windows Event Log, indicating a previous improper shutdown.
Check 24 V DC power supply stability. Inspect power connections and UPS if applicable. Investigate thermal shutdown events. - BIOS POST Error
- Hardware component not detected during Power-On Self-Test, such as missing RAM or storage device.
Reseat RAM modules and storage media. Verify all internal connectors are secure. Replace faulty hardware component if fault persists. - WinCC Runtime Error
- SIMATIC WinCC or WinCC flexible runtime fails to start or crashes during operation.
Check WinCC license dongle or software license. Reinstall WinCC runtime. Verify compatibility between WinCC version and OS. - Network Connection Lost
- Ethernet communication to PLC or network lost, causing HMI to display communication error.
Check RJ45 cable and switch connections. Verify IP address configuration. Check PLC communication settings and PROFINET device names. - Touchscreen Not Responding
- PCT touch input is unresponsive or inaccurate after startup or during operation.
Recalibrate touch interface via Windows control panel. Clean the touch surface. If persistent, check touch controller driver or replace touch overlay.
Frequently Asked Questions
What operating systems are supported by the SIMATIC IPC277D 6AV7285-6HN10-0AA0?
The IPC277D supports Windows Embedded Standard 7 and Windows 7 Professional. It is not natively designed for Windows 10 without specific Siemens upgrade packages.
What is the front panel protection rating of this panel PC?
The front panel of the 6AV7285-6HN10-0AA0 meets IP65 protection, making it resistant to dust and low-pressure water jets. The rear of the unit is rated IP20.
What visualization software is compatible with this panel PC?
The IPC277D is compatible with SIMATIC WinCC, WinCC flexible, and other PC-based SCADA or HMI software running on Windows. It can also run third-party visualization applications.
Does this panel PC support multi-touch input?
Yes, the 6AV7285-6HN10-0AA0 features a projected capacitive (PCT) touch screen that supports multi-finger gesture input, enabling pinch-to-zoom and other multi-touch interactions.
What storage options are available for the IPC277D?
The IPC277D supports CFast cards and solid-state drives (SSD) as storage media, avoiding rotating hard disk drives to improve reliability in vibration-prone industrial environments.
Troubleshooting
Panel PC does not power on after 24 V DC is applied
Measure the 24 V DC supply voltage at the power input connector. Check for blown internal fuses. Verify the power supply unit output is within specification.
Replace the power supply or correct the input voltage if out of range. Replace any blown fuses with the correct rating as specified in the IPC277D hardware manual.
Display remains blank but system appears to be running
Check if the backlight is functioning by shining a light on the display surface to detect a faint image. Verify display cable connections internally.
Replace the backlight or LCD panel if the backlight has failed. If an image is visible but dim, the backlight inverter or LED driver may require replacement.
Touchscreen input is erratic or unresponsive
Check for contamination or moisture on the touch surface. Verify the touch controller driver is correctly installed in Device Manager. Test with a known-good stylus or clean gloves.
Clean the touch surface with a dry lint-free cloth. Reinstall the touch controller driver. If the issue persists, replace the touch overlay or contact Siemens service for a panel replacement.
System freezes or reboots unexpectedly during operation
Check the 24 V DC supply for voltage drops or ripple under load. Review Windows Event Viewer for critical errors. Monitor CPU and system temperatures using diagnostic tools.
Stabilize the power supply and ensure adequate current capacity. Clean ventilation areas to prevent thermal throttling. Replace the CFast or SSD if storage errors are detected.
Ethernet communication to PLC is lost intermittently
Inspect the RJ45 connectors and cables for damage or poor contact. Check network switch port status. Verify IP address and subnet configuration in Windows network settings.
Replace damaged cables or connectors. Assign a static IP address to avoid DHCP conflicts. Update the Ethernet adapter driver and verify PROFINET configuration in the Siemens TIA Portal or STEP 7 project.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page