Siemens 6AV7260-0DD22-0AX6 SIMATIC IPC277D
€ 1.977,00
The Siemens 6AV7260-0DD22-0AX6 is a Panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial PC product line designed for demanding automation and process visualization environments. This unit is a 15-inch multi-touch Panel PC that integrates computing power with a robust operator interface in a single compact device. It is engineered for direct panel mounting and is intended for use as a high-performance HMI solution in industrial settings.
The IPC277D features a 15-inch widescreen TFT display with a projected capacitive (PCT) multi-touch screen supporting up to 5 simultaneous touch points, enabling intuitive operator interaction. It is powered by an Intel Atom processor and supports Windows Embedded Standard 7 or Windows 7 operating systems, providing a familiar computing environment for SCADA and visualization software. The unit includes multiple USB ports, Ethernet interfaces (RJ45), and supports PROFINET communication, making it compatible with Siemens SIMATIC automation architectures. It carries an IP65 protection rating on the front panel, ensuring resistance to dust and water ingress in harsh industrial environments.
The SIMATIC IPC277D is widely deployed in manufacturing automation, process industries, and machine building applications where a robust, panel-mounted HMI with PC functionality is required. It is commonly used to run Siemens WinCC, WinCC flexible, or third-party SCADA software for real-time process monitoring and control. Industries such as automotive, food and beverage, chemical processing, and discrete manufacturing rely on this platform for its reliability, industrial-grade construction, and seamless integration with Siemens SIMATIC controllers.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Type | TFT widescreen |
| Touch Technology | Projected capacitive (PCT) multi-touch, up to 5 touch points |
| Display Resolution | 1024 x 768 px (XGA) |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Input Voltage | 24 V DC |
| Processor | Intel Atom |
| Operating System | Windows Embedded Standard 7 / Windows 7 |
| Communication Interfaces | 2x RJ45 Ethernet (PROFINET), 4x USB |
| Mounting | Panel mounting |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Certifications | CE, UL, cULus |
| Series | SIMATIC IPC277D |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup error or boot failure detected during POST.
Check storage media integrity, verify OS installation, and inspect RAM modules for proper seating. Re-image the storage device if necessary. - Event ID: 200
- Overtemperature warning: internal temperature has exceeded the defined threshold.
Check ambient temperature and ensure adequate ventilation around the panel. Clean cooling vents and verify that the fan (if present) is operational. - Event ID: 300
- Fan failure detected: cooling fan has stopped or is running below minimum speed.
Replace the internal cooling fan. Ensure the unit is powered down before servicing. Check fan connector for secure contact. - Event ID: 400
- UPS battery low or UPS module fault detected.
Replace the UPS battery or UPS module. Verify UPS module is correctly seated and connected. - Event ID: 500
- Hard disk or storage medium error: read/write failure or storage device not detected.
Replace the CompactFlash card or SSD. Back up data before replacement and restore OS image to the new storage device. - Event ID: 600
- PROFINET communication error: loss of connection to the PROFINET controller.
Check Ethernet cable connections, verify IP address configuration, and confirm PROFINET device name assignment in the SIMATIC engineering tool. - Event ID: 700
- Watchdog timeout: the system watchdog has triggered due to software hang or unresponsive application.
Restart the application or reboot the Panel PC. Investigate the software application for memory leaks or infinite loops causing the hang.
Frequently Asked Questions
What is the display size and touch technology used in the 6AV7260-0DD22-0AX6?
The 6AV7260-0DD22-0AX6 features a 15-inch TFT widescreen display with projected capacitive (PCT) multi-touch technology supporting up to 5 simultaneous touch points.
What operating systems are supported by the SIMATIC IPC277D?
The IPC277D supports Windows Embedded Standard 7 and Windows 7, allowing it to run standard Windows-based SCADA and HMI software such as Siemens WinCC.
What is the supply voltage for this Panel PC?
The unit operates on a 24 V DC supply voltage, which is standard for industrial panel-mounted devices in automation environments.
What communication interfaces are available on this unit?
The IPC277D provides two RJ45 Ethernet ports supporting PROFINET, as well as multiple USB ports for peripheral connectivity.
What is the front panel protection rating of the 6AV7260-0DD22-0AX6?
The front panel carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for use in industrial environments.
Troubleshooting
Display remains blank after power on
Measure 24 V DC supply voltage at the power input connector. Check if the power LED is illuminated. Determine whether the unit is booting but the display backlight has failed.
Verify and restore correct 24 V DC supply. If supply is correct and the unit is running but display is blank, the backlight inverter or display panel may need replacement. Re-seat display cable connections internally.
Touch screen does not respond or registers incorrect touch positions
Check for physical damage or contamination on the touch surface. Verify that the PCT touch controller drivers are correctly installed in the operating system.
Clean the touch surface with a soft, dry cloth. Recalibrate the touch screen through the operating system settings. If the issue persists, the touch controller or display assembly may require replacement.
Unit fails to boot and shows POST error or blank screen with no OS loading
Check the CompactFlash card or SSD for proper seating. Attempt to boot from an external USB device to determine if the storage medium has failed.
Re-seat or replace the internal storage device. Re-image the storage medium with the correct OS image using Siemens recovery tools or a standard Windows imaging process.
PROFINET communication lost between IPC277D and SIMATIC PLC
Check physical Ethernet cable connections on both the Panel PC and the switch or PLC port. Verify IP address and PROFINET device name configuration using SIMATIC STEP 7 or TIA Portal.
Replace faulty Ethernet cables, correct IP address conflicts, and reassign the PROFINET device name. Ensure the PROFINET configuration in the engineering project matches the physical device settings.
System overheating or unexpected shutdowns due to high temperature
Check the ambient temperature around the panel installation. Inspect cooling vents for blockage by dust or debris. Verify that the installation cutout provides adequate clearance as specified in the mounting instructions.
Clean all ventilation openings. Ensure the installation environment does not exceed 50 °C ambient temperature. If a cooling fan is fitted, verify it is operational and replace if faulty.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page