Siemens 6AV7260-0DD22-0XX6 SIMATIC IPC277D
€ 1.870,00
The Siemens 6AV7260-0DD22-0XX6 is a Panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial PC product line designed for demanding human-machine interface applications. This unit is a 15-inch multi-touch panel PC that integrates computing power and display functionality into a single compact device suitable for direct panel mounting. It is engineered for use in industrial environments where reliability, longevity, and seamless integration with Siemens automation systems are required.
The IPC277D features a 15-inch widescreen TFT display with a projected capacitive (PCT) multi-touch interface, supporting up to 5 simultaneous touch points for intuitive operator interaction. The unit is based on an Intel Atom processor platform and supports Windows Embedded Standard 7 or Windows 7 Professional operating systems, providing a familiar computing environment for SCADA and HMI software. It includes multiple communication interfaces such as USB 2.0 ports, RJ45 Ethernet ports (PROFINET-capable), and optionally a serial RS-232 interface, enabling broad connectivity to PLCs, drives, and network infrastructure. The front panel carries an IP65 protection rating, making it resistant to dust and water ingress from the front.
The SIMATIC IPC277D is widely deployed in manufacturing, process automation, automotive, food and beverage, and pharmaceutical industries where a robust operator panel with PC functionality is needed. It is commonly used to run Siemens WinCC, WinCC flexible, or third-party SCADA software directly on the panel, eliminating the need for a separate PC. Its fanless design options and industrial-grade components make it suitable for continuous 24/7 operation in environments with vibration, temperature variation, and high humidity.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Type | TFT widescreen |
| Touch Technology | Projected capacitive (PCT) multi-touch, up to 5 touch points |
| Input Voltage | 24 V DC |
| Power Consumption | Approx. 60 W (typical) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interfaces | 2x RJ45 Ethernet (PROFINET), 4x USB 2.0, 1x RS-232 (optional) |
| Operating System | Windows Embedded Standard 7 / Windows 7 Professional |
| Processor | Intel Atom |
| Mounting | Panel mounting (portrait or landscape) |
| Certifications | CE, UL, cULus |
| Series | SIMATIC IPC277D |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST.
Check storage medium (CFast card or SSD) for integrity. Re-image the operating system if the storage device is corrupted. Verify BIOS settings are correct. - Event ID: 101
- Hardware watchdog timeout — the system did not respond within the watchdog interval.
Check CPU load and running processes. Ensure the watchdog service is correctly configured. Restart the panel and investigate any software causing system hangs. - Event ID: 200
- Fan failure detected (if fan-cooled variant). Cooling fan has stopped or is running below threshold speed.
Inspect and clean the fan. Replace the fan unit if it has failed. Ensure ventilation clearances around the device are maintained. - Event ID: 300
- Temperature warning — internal temperature has exceeded the warning threshold.
Check ambient temperature and ensure it is within the 0–50 °C operating range. Clean air vents and verify adequate airflow around the unit. - Event ID: 400
- Supply voltage out of range — input voltage is below or above the 24 V DC nominal tolerance.
Measure the supply voltage at the power connector. Ensure the power supply provides a stable 24 V DC within the specified tolerance (typically 18–30 V DC). - Event ID: 500
- Touch screen calibration error or touch input not responding correctly.
Recalibrate the touch screen via the Windows control panel or Siemens panel configuration tool. If the issue persists, check the touch controller connection internally or replace the touch overlay. - Event ID: 600
- Ethernet communication failure — network interface not detected or link down.
Check Ethernet cable connections and switch/hub status. Verify network adapter settings in Device Manager. Replace the Ethernet cable or check the RJ45 port for damage. - Event ID: 700
- Storage medium error — CFast card or SSD read/write error detected.
Back up data immediately if possible. Run a disk check utility. Replace the CFast card or SSD if errors persist, and restore the operating system image.
Frequently Asked Questions
What is the input voltage for the SIMATIC IPC277D (6AV7260-0DD22-0XX6)?
The unit operates on 24 V DC nominal input voltage, with a typical tolerance range of 18 V DC to 30 V DC. A suitable industrial 24 V DC power supply must be provided externally.
What touch technology does this panel PC use?
The 6AV7260-0DD22-0XX6 uses projected capacitive (PCT) multi-touch technology, supporting up to 5 simultaneous touch points. This allows intuitive gesture-based interaction similar to modern consumer touchscreens.
Is this panel PC compatible with Siemens WinCC and STEP 7?
Yes, the SIMATIC IPC277D is designed to run Siemens WinCC and WinCC flexible HMI software natively. It integrates seamlessly with SIMATIC S7-300, S7-400, and S7-1500 PLCs via PROFINET or Ethernet.
What is the front panel protection rating of this unit?
The front panel of the IPC277D carries an IP65 protection rating, providing complete protection against dust ingress and protection against low-pressure water jets. The rear of the unit is rated IP20.
Can the operating system be reinstalled or re-imaged on this panel PC?
Yes, the operating system can be re-imaged using a Siemens recovery image stored on a USB drive or replacement CFast card. Siemens provides recovery media and documentation for this procedure through their support channels.
Troubleshooting
Display remains blank after power is applied
Check that 24 V DC is present at the power connector using a multimeter. Verify the power LED status on the unit. Attempt to connect an external monitor via VGA or DVI if available to determine if the issue is with the display or the system board.
If supply voltage is correct but display is blank, the internal backlight inverter or display panel may have failed. Replace the display assembly or backlight unit. If no video output is detected on an external monitor either, the main board may require replacement or repair.
Touch screen does not respond or registers incorrect touch positions
Check if the touch screen is correctly calibrated in the Windows control panel. Determine whether the issue is present across the entire screen or only in specific zones. Check Device Manager for touch controller errors.
Recalibrate the touch screen using the Windows Tablet PC Settings or Siemens configuration utility. If calibration does not resolve the issue, clean the screen surface thoroughly and check for physical damage. Replace the touch overlay or touch controller board if the hardware is faulty.
Panel PC fails to boot or gets stuck at the Windows startup screen
Attempt to boot into Windows Safe Mode by pressing F8 during startup. Check the CFast card or SSD for errors using a disk check utility. Review Windows Event Viewer logs for critical errors recorded before the failure.
Run a disk integrity check and repair corrupted system files using Windows recovery tools. If the storage medium is faulty, replace the CFast card or SSD and restore the operating system from a Siemens recovery image.
Ethernet communication is not established with the PLC or network
Check the physical Ethernet cable connection and verify the link LED on the RJ45 port is illuminated. Open Device Manager to confirm the network adapter is recognized and has no errors. Verify IP address configuration matches the network subnet.
Replace the Ethernet cable if the link LED is not lit. Update or reinstall the network adapter driver if Device Manager shows an error. Reconfigure the IP address settings in Windows Network Connections to match the required network configuration.
Unit shuts down unexpectedly or restarts during operation
Check the ambient temperature around the unit and inspect ventilation clearances. Review Windows Event Viewer for thermal warnings or watchdog timeout events. Measure the 24 V DC supply voltage under load to check for voltage drops.
Ensure the operating environment is within the 0–50 °C range and that ventilation slots are not obstructed. Stabilize the power supply if voltage drops are detected. If thermal shutdown is confirmed, clean internal components and ensure the cooling solution (heatsink or fan) is functioning correctly.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page