Siemens 6AV6646-1BA15-0AA1 SIMATIC KTP600 Basic
€ 683,00
The Siemens 6AV6646-1BA15-0AA1 is a KTP600 Basic Color PN panel belonging to the SIMATIC Basic Panel series from Siemens. It is a compact key and touch-operated HMI panel featuring a 5.7-inch TFT color display, designed for straightforward machine-level visualization tasks. This panel is part of the Basic Panel generation introduced alongside the SIMATIC S7-1200 PLC family and is configured using WinCC Basic within the TIA Portal engineering framework.
The KTP600 Basic Color PN communicates via PROFINET (Ethernet), making it compatible with SIMATIC S7-1200 and S7-300/400 controllers. It features a 5.7-inch TFT display with a resolution of 320 x 240 pixels and 256 colors, combined with a resistive touch screen and 6 configurable function keys. The panel operates on 24 V DC and offers 10 MB of user memory for project data. It supports alarm management, recipe handling, and trend display functions within its firmware capabilities.
The KTP600 Basic Color PN is widely used in small to medium-scale machine automation applications across industries such as packaging, food and beverage, material handling, and general manufacturing. Its compact form factor and PROFINET connectivity make it well suited for integration into distributed machine panels and control cabinets where a cost-effective yet capable HMI solution is required. The panel's compatibility with TIA Portal simplifies engineering and commissioning workflows.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Resolution | 320 x 240 pixels (QVGA) |
| Display Colors | 256 colors |
| Display Type | TFT LCD |
| Touch Technology | Resistive touch screen |
| Function Keys | 6 configurable function keys |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | 4.5 W (typical) |
| Communication Interface | PROFINET (RJ45 Ethernet) |
| User Memory | 10 MB |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP Protection Rating | IP65 (front panel) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC Basic Panel |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between HMI panel and PLC. The connection to the configured controller has been lost or cannot be established.
Check PROFINET cable and RJ45 connector integrity. Verify IP address configuration on both the panel and PLC. Ensure the PLC is in RUN mode and the network switch or router is operational. - Event ID: 10001
- Connection to PLC interrupted during runtime. The HMI lost communication with the controller unexpectedly.
Inspect network cabling for damage or loose connections. Check PLC CPU status. Restart the HMI panel and verify project communication settings in TIA Portal. - Event ID: 20000
- Project download error. The project could not be transferred to the panel successfully.
Verify that the PC and panel are on the same network subnet. Check that the correct panel type and firmware version are selected in TIA Portal. Retry the download after restarting both devices. - Event ID: 40000
- Firmware update error. The firmware update process was interrupted or failed to complete.
Restart the panel and attempt the firmware update again using ProSave or TIA Portal. Ensure stable power supply during the update process and do not disconnect the network cable. - Event ID: 50000
- Internal device error. A hardware or system fault has been detected within the panel.
Perform a factory reset via the Start Center menu. If the fault persists after reset and re-download of the project, the panel may require repair or replacement. - Event ID: 60000
- Tag read/write error. The HMI is unable to read from or write to a configured PLC tag.
Verify that the PLC tag addresses configured in the HMI project match the actual PLC data block or memory addresses. Check PLC access permissions and ensure the data block is not set to optimized access if using absolute addressing. - Event ID: 70000
- Recipe data error. A recipe record could not be read from or written to the panel memory.
Check available user memory on the panel. Verify recipe configuration in TIA Portal and ensure recipe data types match the connected PLC tags. Clear corrupted recipe data and re-transfer the project.
Frequently Asked Questions
What PLC families are compatible with the KTP600 Basic Color PN?
The KTP600 Basic Color PN is primarily designed for use with the SIMATIC S7-1200 PLC family. It also supports communication with S7-300 and S7-400 controllers via PROFINET using the appropriate driver configuration in TIA Portal.
What software is required to configure the 6AV6646-1BA15-0AA1?
This panel is configured using WinCC Basic, which is included with TIA Portal. A standalone version of WinCC (such as WinCC Comfort or Advanced) is not required and cannot be used for this panel.
Does the KTP600 Basic support USB for project transfer?
The KTP600 Basic Color PN does not feature a USB port. Project transfer is performed exclusively via the PROFINET Ethernet interface using TIA Portal or the ProSave utility.
What is the front panel protection rating of this HMI?
The front panel of the 6AV6646-1BA15-0AA1 carries an IP65 protection rating, making it suitable for installation in environments where dust and water jets may be present.
Can the KTP600 Basic Color PN display trend curves and alarms?
Yes, the KTP600 Basic Color PN supports alarm management including alarm views and alarm indicators, as well as trend display and recipe management within the capabilities of WinCC Basic.
Troubleshooting
Display remains blank after power on
Measure the 24 V DC supply voltage at the panel power connector. Check that polarity is correct and voltage is within the 20.4–28.8 V DC operating range.
Correct any wiring errors or supply voltage issues. If the supply voltage is confirmed correct and the display remains blank, the internal power supply or backlight may be faulty and the panel should be sent for repair.
Touchscreen does not respond to input
Verify whether the function keys still operate correctly. Attempt to navigate the Start Center using function keys. Check if the touch area is physically damaged or contaminated.
Clean the touch surface with a soft, dry cloth. Recalibrate the touch screen via the Start Center settings if the option is available. If the touch screen remains unresponsive, the touch glass or controller board may require replacement.
Panel cannot be found on the network during project download
Check the IP address assigned to the panel via the Start Center network settings. Confirm that the engineering PC and the panel are on the same IP subnet and that no firewall is blocking the connection.
Assign a compatible static IP address to the panel through the Start Center. Disable any active firewall on the engineering PC temporarily during download. Use a direct Ethernet cable connection between PC and panel to eliminate network switch issues.
HMI displays 'Connection to PLC interrupted' message during operation
Check the PROFINET cable between the panel and PLC or network switch. Verify the PLC is powered and in RUN mode. Check for IP address conflicts on the network.
Replace the Ethernet cable if damaged. Resolve any IP address conflicts by assigning unique addresses to all devices. Ensure the PLC program is running and the PROFINET interface on the PLC is correctly configured.
Panel repeatedly restarts or enters an error loop after project download
The downloaded project may be incompatible with the installed firmware version on the panel. Check the firmware version in the Start Center and compare it with the TIA Portal project requirements.
Update the panel firmware to the version required by the TIA Portal project using ProSave or TIA Portal's firmware update function. After updating, re-download the project and verify stable operation.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page