Siemens 6AV6646-1BA15-0NA0 SIMATIC KTP1500 Basic
€ 783,00
The Siemens 6AV6646-1BA15-0NA0 is a SIMATIC KTP1500 Basic Panel, part of the Siemens SIMATIC HMI Basic Panel family. It features a 15.6-inch widescreen TFT display and is designed for entry-level HMI applications requiring a compact, cost-effective operator interface. This panel is configured and operated using Siemens WinCC Basic software, included with STEP 7 Basic and TIA Portal.
The KTP1500 Basic offers a 65,536-color TFT display with a resolution of 1366 x 768 pixels and supports both touch operation and 8 configurable function keys for flexible operator input. It communicates via PROFINET (Ethernet) interface, enabling seamless integration with Siemens S7-1200 and S7-1500 PLCs. The panel includes 10 MB of user memory for project data and operates on a 24 V DC supply. It carries CE, UL, and cULus certifications and is rated IP65 on the front face for protection against dust and water ingress.
The SIMATIC KTP1500 Basic is widely used in machine building, packaging, food and beverage processing, and general factory automation where a large, clear operator display is required without the complexity of a full-featured panel PC. Its widescreen format and function key combination make it suitable for applications requiring both touch-based navigation and dedicated physical key inputs. The PROFINET interface allows straightforward network integration in modern automation architectures.
Technical Specifications
| Display Size | 15.6 inch |
|---|---|
| Display Resolution | 1366 x 768 pixels |
| Display Colors | 65,536 colors |
| Display Type | TFT widescreen |
| Touch Technology | Resistive touch screen |
| Function Keys | 8 configurable function keys |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Typical 25 W |
| Communication Interface | PROFINET (1x RJ45 Ethernet) |
| User Memory | 10 MB |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Certifications | CE, UL, cULus |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC HMI Basic Panel |
Common Error Codes & System Events
- Event ID: 10000
- Connection to the PLC could not be established or was interrupted.
Check PROFINET cable and connections. Verify IP address configuration of both the panel and the PLC. Ensure the PLC is in RUN mode. - Event ID: 10001
- Communication timeout with the configured PLC controller.
Check network integrity and switch/hub connections. Verify PLC program is running and the HMI connection tag addresses are correct in TIA Portal. - Event ID: 20000
- Project download failed or project data is corrupted.
Re-download the project from TIA Portal. Ensure WinCC Basic version is compatible with the panel firmware version. Perform a panel reset if necessary. - Event ID: 40000
- Internal device error or hardware fault detected.
Perform a factory reset via the Start Center. If the fault persists, the panel may require repair or replacement of internal components. - Event ID: 50000
- Firmware update error — firmware transfer was interrupted or incompatible firmware was loaded.
Retry the firmware update using the correct firmware version from the Siemens support portal. Use ProSave or TIA Portal to re-flash the firmware. - Event ID: 70000
- Insufficient user memory — project data exceeds available panel memory.
Reduce project size in WinCC Basic by optimizing graphics, removing unused tags, or compressing image resources. Ensure project does not exceed 10 MB. - Event ID: 30000
- Tag update cycle time exceeded — HMI cannot read tags within the configured acquisition cycle.
Increase the acquisition cycle time for affected tags in TIA Portal. Reduce the number of tags polled simultaneously or optimize PLC communication load.
Frequently Asked Questions
Which PLCs are compatible with the SIMATIC KTP1500 Basic (6AV6646-1BA15-0NA0)?
The KTP1500 Basic is primarily designed for use with Siemens S7-1200 and S7-1500 PLCs via PROFINET. It can also communicate with S7-300 and S7-400 controllers over Ethernet using appropriate configuration in TIA Portal.
What software is required to configure the KTP1500 Basic?
The panel is configured using Siemens WinCC Basic, which is included with TIA Portal (STEP 7 Basic or STEP 7 Professional). No separate HMI software license is required for WinCC Basic.
What is the display resolution and size of the 6AV6646-1BA15-0NA0?
The panel features a 15.6-inch widescreen TFT display with a resolution of 1366 x 768 pixels and supports 65,536 colors.
Does the KTP1500 Basic support both touch and key operation?
Yes, the KTP1500 Basic supports resistive touch screen input as well as 8 configurable function keys, allowing flexible operator interaction.
What is the front panel protection rating of the KTP1500 Basic?
The front face of the KTP1500 Basic is rated IP65, providing protection against dust and low-pressure water jets, making it suitable for industrial panel mounting environments.
Troubleshooting
Display remains blank after power on
Measure the 24 V DC supply voltage at the panel power connector. Check that polarity is correct and voltage is within the 20.4–28.8 V DC operating range.
Correct the supply voltage or wiring. If voltage is correct and display remains blank, attempt a panel reset by holding the reset button. If unresolved, the internal power supply or backlight may require replacement.
Touchscreen does not respond or responds inaccurately
Check for physical damage or contamination on the touch surface. Verify that the touch calibration has not been lost, which can occur after a firmware update or factory reset.
Clean the touch surface with a soft, dry cloth. Recalibrate the touchscreen via the Start Center settings menu. If the issue persists, the resistive touch overlay may be damaged and require panel repair.
Panel cannot connect to PLC via PROFINET
Verify the Ethernet cable is properly seated and the link LED on the RJ45 port is active. Check that the panel IP address and PLC IP address are on the same subnet and match the TIA Portal project configuration.
Correct IP address settings in the panel Start Center under Network Settings. Re-download the project from TIA Portal. Replace the Ethernet cable if the link LED does not illuminate.
Project download from TIA Portal fails or times out
Check the network connection between the engineering PC and the panel. Verify that the panel is in transfer mode (accessible via the Start Center) and that firewall or antivirus software is not blocking the TIA Portal communication.
Switch the panel to Transfer mode manually via the Start Center. Disable firewall exceptions for TIA Portal on the PC. Ensure the WinCC Basic version matches the panel firmware version and retry the download.
Panel repeatedly restarts or shows a boot loop
This may indicate corrupted project data or a failed firmware update. Observe whether the Start Center loads before the restart occurs, which helps distinguish between a firmware issue and a project runtime error.
Boot into the Start Center and perform a factory reset to clear corrupted project data. If the panel does not reach the Start Center, re-flash the firmware using ProSave via the Ethernet interface from a PC.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page