The Siemens 6AV6381-2CB08-0AX3 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across the SIMATIC range.
WinCC flexible 2008 offers a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and report generation. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Ethernet interfaces. It provides a scalable architecture allowing projects to be migrated from smaller panels to larger systems, and includes multilingual project support for international deployments. The 2008 edition introduced improved performance, extended device support, and enhanced integration with the SIMATIC automation environment.
WinCC flexible 2008 is widely used in manufacturing automation, process control, and machine building applications across industries such as automotive, food and beverage, pharmaceuticals, and water treatment. It is suitable for configuring operator panels ranging from Micro Panels and Mobile Panels to multi-panel and PC-based SCADA installations. The software's scalability and compatibility with the broader SIMATIC ecosystem make it a standard engineering tool for system integrators and OEMs working with Siemens automation platforms.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| License Type | Engineering Software License |
| Compatible PLC Families | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces | MPI, PROFIBUS DP, Industrial Ethernet |
| Supported Panel Families | SIMATIC Micro Panel, Mobile Panel, OP, TP, MP series |
| Operating System | Windows XP, Windows Vista, Windows 7 (32-bit) |
| Project Languages | Up to 32 languages per project |
| Alarm Management | Included (bit alarms, analog alarms, system alarms) |
| Recipe Management | Included |
| Trend Display | Included |
| Report System | Included |
| Series/Product Family | SIMATIC WinCC flexible |
Common Error Codes & System Events
- Event ID: 1000
- Project could not be opened — project file is corrupt or incompatible with the installed software version.
Verify the project was created with a compatible version of WinCC flexible. Attempt to restore from a backup or use the project migration tool. - Event ID: 1010
- License not found — no valid license key detected for WinCC flexible Engineering or Runtime.
Check that the license dongle (USB) is connected or that the software license is correctly installed using the Siemens Automation License Manager (ALM). - Event ID: 1020
- Communication error — the HMI panel cannot establish a connection to the configured PLC.
Verify PLC address settings, cable connections, and communication driver configuration. Check that the PLC is in RUN mode and the correct protocol is selected. - Event ID: 1030
- Tag limit exceeded — the number of configured tags exceeds the license or panel limit.
Reduce the number of tags in the project or upgrade the license to a higher tag count tier. - Event ID: 1040
- Compilation error — the project contains configuration errors preventing successful compilation.
Review the error list in the compiler output window, correct all flagged configuration issues, and recompile the project. - Event ID: 1050
- Transfer failed — project transfer to the HMI panel was interrupted or unsuccessful.
Check the transfer cable or network connection, ensure the panel is in Transfer mode, and verify that the correct transfer channel is configured in the project settings. - Event ID: 1060
- Runtime startup error — WinCC flexible Runtime failed to start on the target panel or PC.
Check available memory on the target device, verify Runtime license validity, and ensure the project file is not corrupted. Restart the device and attempt to reload the project.
Frequently Asked Questions
Which PLC families are compatible with WinCC flexible 2008?
WinCC flexible 2008 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet interfaces.
What operating systems does WinCC flexible 2008 support for the engineering station?
WinCC flexible 2008 is compatible with Windows XP, Windows Vista, and Windows 7 (32-bit). It is not natively supported on 64-bit operating systems without compatibility measures.
Is a hardware dongle required to run WinCC flexible 2008?
A valid Siemens license is required, managed through the Siemens Automation License Manager (ALM). Depending on the license type, this may be tied to a USB dongle or a software-based license key.
Can WinCC flexible 2008 projects be migrated to TIA Portal?
Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible 2008 projects, though some manual rework may be required depending on the complexity of the project.
How many HMI devices can be configured in a single WinCC flexible 2008 project?
WinCC flexible 2008 supports multi-panel projects, allowing multiple HMI devices to be configured within a single project file, with the exact number depending on the license edition (Compact, Standard, or Advanced).
Troubleshooting
WinCC flexible 2008 fails to install on Windows 7
Check whether the operating system is 32-bit or 64-bit. Verify that all prerequisites such as .NET Framework and SIMATIC software components are installed.
Ensure the installation is performed on a 32-bit Windows 7 system. Install all required prerequisite software listed in the WinCC flexible 2008 readme file before running the main installer.
License error appears when opening or compiling a project
Open the Siemens Automation License Manager (ALM) and check whether a valid WinCC flexible Engineering license is present and not expired or transferred.
Reconnect the USB license dongle if used, or use ALM to transfer the license back to the engineering PC. Contact Siemens license support if the license appears corrupted.
Project transfer to HMI panel fails repeatedly
Verify the transfer channel settings in the project (Ethernet, USB, or serial) and confirm the panel is set to Transfer mode. Check firewall settings on the engineering PC.
Disable Windows Firewall temporarily during transfer, ensure the correct IP address or COM port is configured, and confirm the panel firmware version is compatible with the project settings.
Communication between HMI and PLC drops intermittently at runtime
Check the physical connection (cable integrity, switch/hub status) and review the communication driver settings including PLC address, timeout values, and polling cycle.
Replace faulty cables, verify correct PLC station address configuration in the WinCC flexible project, and increase communication timeout values in the connection settings if network latency is a factor.
Compiled project produces warnings about unsupported functions on target panel
The project may have been configured for a different or higher-capability panel than the target device, resulting in features not supported by the target hardware.
Open the project properties and verify the target panel type matches the physical device. Remove or replace unsupported objects and recompile the project before transferring.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page