
Siemens 6AV6381-2CB08-0AX0 WinCC flexible 2008
€ 1.995,00
The Siemens 6AV6381-2CB08-0AX0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for a wide range of operator panels.
WinCC flexible 2008 offers a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and script-based automation. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet interfaces. It includes a library of pre-built faceplates and symbols, supports multi-language project configuration, and is compatible with a broad range of Siemens HMI hardware including the TP, OP, MP, and Mobile Panel series.
WinCC flexible 2008 is widely used in manufacturing automation, process control, and machine building applications across industries such as automotive, food and beverage, pharmaceuticals, and packaging. It is particularly suited for projects requiring scalable HMI solutions that span from small operator panels to multi-panel SCADA-like installations. The software's compatibility with the broader SIMATIC ecosystem makes it a standard choice for system integrators and OEMs working within Siemens automation environments.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| Series/Product Family | SIMATIC WinCC flexible |
| License Type | Engineering Software License |
| Supported PLC Families | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces | MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP) |
| Supported HMI Hardware | SIMATIC TP, OP, MP, Mobile Panel series |
| Operating System | Windows XP, Windows Vista, Windows 7 |
| Project Languages | Multi-language support |
| Certifications | CE |
| Alarm Logging | Supported |
| Recipe Management | Supported |
| Trend Display | Supported |
| Scripting | VB Script support |
Common Error Codes & System Events
- Event ID: 1000
- Runtime startup error — WinCC flexible Runtime failed to initialize correctly on the target system.
Verify that the correct runtime version is installed and that the license key is valid. Restart the runtime application and check the Windows event log for additional detail. - Event ID: 1003
- Communication error — The HMI panel or PC runtime cannot establish a connection to the configured PLC.
Check the physical communication cable and interface settings. Verify PLC address, baud rate, and protocol settings match the project configuration. - Event ID: 1010
- Tag read/write error — A configured tag could not be read from or written to the PLC.
Confirm the tag address exists in the PLC program and that the data type matches the WinCC flexible tag configuration. Check communication status. - Event ID: 1020
- License not found — No valid license for WinCC flexible Engineering or Runtime was detected.
Insert the valid license key or use the Automation License Manager to transfer the license to the engineering PC or target device. - Event ID: 1030
- Project download error — The project could not be successfully transferred to the target HMI panel.
Check the download connection (USB, Ethernet, or MPI). Ensure the target panel firmware version is compatible with the WinCC flexible 2008 project version. - Event ID: 1040
- Alarm buffer overflow — The alarm buffer on the runtime system has reached its maximum capacity.
Increase the alarm buffer size in the project settings or implement alarm archiving to an external database to prevent buffer overflow. - Event ID: 1050
- Recipe data error — A recipe record could not be read or written correctly.
Verify the recipe configuration, including data record structure and tag assignments. Check available memory on the target device for recipe storage. - Event ID: 1060
- Script execution error — A VB Script within the project encountered a runtime error during execution.
Review the script logic in the WinCC flexible engineering environment. Check for invalid variable references, type mismatches, or unhandled exceptions in the script code.
Frequently Asked Questions
Which PLC families are compatible with WinCC flexible 2008?
WinCC flexible 2008 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet interfaces.
What operating systems are supported for the engineering software?
WinCC flexible 2008 is compatible with Windows XP, Windows Vista, and Windows 7. It is not officially supported on Windows 10 or later without compatibility workarounds.
Can WinCC flexible 2008 projects be migrated to TIA Portal?
Yes, Siemens provides a migration tool within TIA Portal that allows WinCC flexible 2008 projects to be imported and converted, though some manual rework may be required depending on project complexity.
What HMI hardware panels are supported by WinCC flexible 2008?
The software supports the full range of SIMATIC HMI panels including the TP (Touch Panel), OP (Operator Panel), MP (Multi Panel), and Mobile Panel series from Siemens.
Is a separate runtime license required in addition to the engineering license?
Yes, a separate WinCC flexible Runtime license is required to run the HMI application on a PC-based system. Panel-based HMI devices include the runtime license with the hardware.
Troubleshooting
WinCC flexible 2008 fails to install or throws a license error on startup
Check the Automation License Manager to verify whether a valid license is present on the engineering PC. Confirm the license matches the installed software version and edition.
Transfer a valid license using the Siemens Automation License Manager. If the license is on a USB dongle, ensure it is connected before launching the software. Re-install the software if the installation is corrupted.
Project cannot be downloaded to the HMI panel
Verify the download connection type (USB, Ethernet, or MPI/PROFIBUS) and confirm the correct interface is selected in the transfer settings. Check that the panel is in transfer mode.
Set the HMI panel to transfer mode via the Start Center or Control Panel on the device. Ensure the PC network adapter settings or COM port settings match the configured download interface in WinCC flexible.
Runtime communication to PLC is lost intermittently
Check the physical communication cable for damage or loose connections. Review the PLC connection parameters in the project, including IP address, rack, and slot number for Ethernet connections.
Replace faulty cables and verify all connection parameters. For Ethernet connections, check network switch health and ensure no IP address conflicts exist. Increase the communication timeout value in the connection settings if the network has high latency.
Alarms are not displayed on the HMI panel during runtime
Verify that the alarm tags are correctly configured and that the PLC bit addresses assigned to alarms are being set by the PLC program. Check that the alarm view object is present and enabled on the relevant screen.
Correct any misconfigured alarm tag addresses and ensure the PLC logic is writing to the correct memory locations. Confirm the alarm view control is not hidden or filtered in the runtime project settings.
WinCC flexible Engineering software crashes when opening a project
Check the Windows event log for application crash details. The issue may be related to a corrupted project file, insufficient system resources, or an incompatible software component.
Restore the project from a recent backup. Ensure the PC meets the minimum system requirements for WinCC flexible 2008. Repair or reinstall the software using the original installation media if crashes persist.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page



