• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2CB08-0AX4 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2CB08-0AX4 WinCC flexible 2008

    € 584,41

    Reset
    Clear
    SKU: 6AV6381-2CB08-0AX4 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2CB08-0AX4 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across a wide range of automation tasks.

    WinCC flexible 2008 offers a scalable engineering environment supporting a broad range of Siemens HMI hardware, from Micro Panels to Multi Panels and PC-based systems. The software includes tools for screen design, alarm management, recipe handling, trend displays, and user administration. It supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS, and Ethernet interfaces, and is compatible with Windows XP and Windows Vista operating systems.

    This software is widely used in manufacturing, process automation, machine building, and plant engineering applications. It is particularly suited for OEMs and system integrators who need a unified engineering tool to configure multiple HMI devices within a single project environment. The scalability of WinCC flexible 2008 makes it applicable in industries such as automotive, food and beverage, pharmaceuticals, and water treatment.

    Technical Specifications

    Software Version WinCC flexible 2008
    Software Type Engineering Software / HMI Configuration Tool
    License Type Single License
    Compatible HMI Hardware SIMATIC Micro Panels, OP/TP Series, Multi Panels, PC-based HMI
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP)
    Operating System Windows XP (SP2 or higher), Windows Vista
    Alarm Management Included
    Recipe Management Included
    Trend Display Included
    User Administration Included
    Series/Product Family SIMATIC WinCC flexible
    Certifications CE

    Common Error Codes & System Events

    Event ID: 1000000
    Runtime startup error — WinCC flexible Runtime failed to initialize correctly on the target system.
    Check that the correct runtime version is installed and that the project file is compatible with the installed runtime version. Reinstall runtime if necessary.
    Event ID: 1000020
    Communication error — Connection to the configured PLC could not be established.
    Verify PLC connection settings (IP address, MPI address, or PROFIBUS address). Check physical cabling and ensure the PLC is powered and in RUN mode.
    Event ID: 1000030
    Tag read/write error — A process tag could not be read from or written to the PLC.
    Check the tag address configuration in the project. Verify that the PLC data block or memory area referenced by the tag exists and is accessible.
    Event ID: 1000040
    License error — No valid license found for WinCC flexible Engineering or Runtime.
    Verify that the license dongle (USB or software license) is correctly installed. Use the Siemens Automation License Manager to check license status and transfer if required.
    Event ID: 1000050
    Project transfer error — Transfer of the project to the HMI panel failed.
    Check the transfer connection (USB, Ethernet, or MPI). Ensure the HMI panel is in Transfer mode and that the correct interface is selected in the transfer settings.
    Event ID: 1000060
    Alarm overflow — The alarm buffer has reached its maximum capacity.
    Acknowledge and clear pending alarms. Review alarm configuration to reduce unnecessary alarm generation and increase buffer size in project settings if possible.
    Event ID: 1000070
    Recipe data error — Recipe data could not be read from or written to the configured data source.
    Check recipe configuration and verify that the associated PLC tags and data records are correctly defined and accessible.
    Event ID: 1000080
    Screen object error — One or more screen objects could not be rendered due to missing or incompatible resources.
    Recompile the project in WinCC flexible Engineering and retransfer to the target device. Check for missing images or fonts referenced in the project.

    Frequently Asked Questions

    Which SIMATIC HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports a wide range of Siemens SIMATIC HMI panels including Micro Panels (KP/TP 170 Micro), Operator Panels (OP 77A/B), Touch Panels (TP 177A/B), Multi Panels (MP 277, MP 377), and PC-based HMI systems running WinCC flexible Runtime.

    Which PLC families can communicate with WinCC flexible 2008 projects?

    WinCC flexible 2008 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet (TCP/IP) interfaces.

    Is a hardware dongle required to run WinCC flexible 2008?

    Yes, WinCC flexible 2008 requires a valid license managed through the Siemens Automation License Manager (ALM). The license can be stored on a USB dongle or transferred to the hard drive of the engineering PC.

    Can WinCC flexible 2008 projects be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that allows WinCC flexible projects to be imported and converted, though some manual rework may be required depending on the complexity of the project.

    What operating systems are compatible with WinCC flexible 2008?

    WinCC flexible 2008 is compatible with Windows XP (Service Pack 2 or higher) and Windows Vista. It is not officially supported on Windows 7 or later without additional compatibility measures.

    Troubleshooting

    WinCC flexible Engineering software fails to start after installation

    Check the Windows Event Viewer for application errors. Verify that the Automation License Manager is installed and a valid license is present. Confirm that the PC meets the minimum hardware and OS requirements.

    Reinstall the Automation License Manager and ensure the license is correctly activated. If the issue persists, perform a repair installation of WinCC flexible 2008 using the original installation media.

    Project cannot be transferred to the HMI panel

    Verify the transfer interface settings in WinCC flexible match the physical connection being used (USB, Ethernet, or MPI/PROFIBUS). Confirm the HMI panel is set to Transfer mode and is powered on.

    Correct the interface settings in the Transfer dialog. Restart the HMI panel in Transfer mode and retry the transfer. If using Ethernet, ensure both devices are on the same subnet and no firewall is blocking the connection.

    Runtime on HMI panel shows 'No connection' to PLC

    Check the communication parameters configured in the project (PLC address, interface type, baud rate). Verify physical cabling between the HMI panel and PLC. Check PLC is powered and in RUN or STOP mode.

    Correct the PLC address and communication interface settings in the WinCC flexible project and retransfer. Replace or reseat communication cables. If using PROFIBUS, verify bus termination resistors are correctly placed.

    License error displayed when opening WinCC flexible Engineering

    Open the Siemens Automation License Manager and check whether a valid WinCC flexible 2008 Engineering license is listed and active. Check if the USB dongle is connected and recognized by the PC.

    Reconnect the USB license dongle and refresh the Automation License Manager. If the license is stored on the hard drive, verify it has not been corrupted or moved. Contact Siemens support to reactivate the license if it is shown as invalid.

    Alarms are not displayed correctly on the HMI panel at runtime

    Check the alarm configuration in the WinCC flexible project, including trigger tags, alarm classes, and display settings. Verify that the PLC tags linked to alarm triggers are correctly addressed and communicating.

    Recheck and correct alarm tag addresses in the project. Recompile and retransfer the project to the HMI panel. Ensure the alarm view object on the screen is correctly configured to display the relevant alarm classes.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart