• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2CA08-0AX4 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2CA08-0AX4 WinCC flexible 2008

    € 320,12

    Reset
    Clear
    SKU: 6AV6381-2CA08-0AX4 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2CA08-0AX4 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens operator panels and SCADA systems. It belongs to the broader SIMATIC HMI software portfolio and is used to create visualization projects for industrial automation systems.

    WinCC flexible 2008 offers a comprehensive set of engineering tools for designing HMI screens, configuring alarms, managing tags, and setting up communication with SIMATIC PLCs and third-party controllers. The software supports a wide range of communication protocols including PROFIBUS, PROFINET, MPI, and Ethernet, enabling integration with S7-200, S7-300, S7-400, and S7-1200 controller families. It includes features such as faceplates, scripting via VBScript, recipe management, trend displays, and multi-language project support. The 2008 version introduced enhanced usability improvements and extended panel compatibility across the SIMATIC HMI device range.

    WinCC flexible 2008 is used across a broad range of industries including automotive manufacturing, food and beverage processing, chemical production, and machine building. It is the standard engineering tool for configuring Siemens SIMATIC HMI panels such as the TP, OP, MP, and Mobile Panel series. Its scalability from small operator panels to multi-station SCADA installations makes it suitable for both standalone machine-level HMI applications and larger distributed visualization systems.

    Technical Specifications

    Software Version WinCC flexible 2008
    License Type Single-user engineering license
    Compatible Controllers SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces PROFIBUS, PROFINET, MPI, Ethernet (TCP/IP)
    Supported HMI Devices SIMATIC HMI TP, OP, MP, Mobile Panel series
    Scripting Support VBScript
    Multi-language Support Yes, multiple project languages supported
    Recipe Management Yes
    Alarm Management Yes, with alarm logging and archiving
    Trend Display Yes
    Operating System Windows XP, Windows Vista, Windows 7 (32-bit)
    Series/Product Family SIMATIC WinCC flexible

    Common Error Codes and System Events

    Event ID: 1000000
    Project could not be opened due to version incompatibility between the engineering software and the project file.
    Ensure the correct version of WinCC flexible is installed. Migrate the project using the project migration wizard if upgrading from an older version.
    Event ID: 2000001
    Communication connection to the PLC could not be established at runtime.
    Check physical network connections, verify IP address or PROFIBUS address settings, and confirm the PLC is powered and in RUN mode.
    Event ID: 3000010
    Tag read/write error — the configured tag address does not exist in the connected controller.
    Verify the tag address in the HMI project matches the actual data block or memory address in the PLC program.
    Event ID: 4000005
    License not found — the runtime license for WinCC flexible Runtime is missing or invalid.
    Install the correct runtime license using the Siemens Automation License Manager (ALM). Ensure the license matches the panel type and runtime size.
    Event ID: 5000002
    Project compilation error — one or more objects in the project contain configuration errors.
    Review the error list in the engineering software, correct all flagged configuration issues, and recompile the project before downloading.
    Event ID: 6000003
    Download to HMI device failed — connection to the target panel could not be established.
    Check the transfer cable or network connection to the HMI panel, ensure the panel is in transfer mode, and verify the correct transfer channel is selected in the project settings.
    Event ID: 7000004
    Alarm log overflow — the alarm archive has exceeded its configured storage limit.
    Increase the alarm archive size in the project settings or configure automatic archiving to an external storage location to prevent data loss.

    Frequently Asked Questions

    Which operating systems are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports Windows XP, Windows Vista, and Windows 7 (32-bit editions). It is not natively compatible with Windows 10 or Windows 11 without additional compatibility measures.

    Which SIMATIC HMI panels can be configured with this software?

    WinCC flexible 2008 supports the full range of SIMATIC HMI panels including the TP, OP, MP, and Mobile Panel series. Compatibility depends on the specific edition of WinCC flexible 2008 installed (Compact, Standard, Advanced, or Comprehensive).

    Can WinCC flexible 2008 projects be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that allows WinCC flexible projects to be imported and converted. Some manual rework may be required depending on the complexity of the original project.

    What communication protocols does WinCC flexible 2008 support?

    The software supports PROFIBUS DP, PROFINET IO, MPI, TCP/IP Ethernet, and various third-party protocols through optional communication drivers. This enables connectivity with both Siemens and non-Siemens controllers.

    Is a separate runtime license required in addition to this engineering license?

    Yes, the engineering license (6AV6381-2CA08-0AX4) covers project design and configuration only. A separate WinCC flexible Runtime license is required for each HMI device that will run the project in production.

    Troubleshooting

    Software fails to install or reports a license error during installation

    Check whether the Automation License Manager (ALM) is installed and whether a valid license key is present on the engineering PC or USB dongle.

    Install or reinstall the Siemens Automation License Manager, then transfer the correct license for WinCC flexible 2008 to the PC using the ALM tool. Ensure the license matches the purchased edition.

    Project cannot be compiled due to multiple errors after opening an existing file

    The project may have been created with a different version of WinCC flexible or contains references to HMI device types not supported by the installed edition.

    Check the project's target device settings and ensure the correct HMI device type is selected. Use the project migration wizard if the project was created in an older WinCC flexible version.

    Runtime communication between HMI panel and PLC is intermittent or fails

    Verify the network or fieldbus configuration in the project, including IP addresses, subnet masks, PROFIBUS node addresses, and connection parameters.

    Correct any addressing conflicts, ensure the PLC program is running and accessible, and check physical cabling and switch/hub configuration. Re-download the project to the panel after making corrections.

    Download to HMI panel fails with a connection timeout error

    The panel may not be in transfer mode, or the PC and panel may be on different network subnets with no route between them.

    Set the HMI panel to transfer mode via its start center menu, verify that the PC and panel share the same subnet, and confirm the correct transfer channel (Ethernet or USB) is configured in the project transfer settings.

    Alarm archive fills up rapidly and older alarms are lost

    The alarm archive size configured in the project is too small for the volume of alarms being generated, or archiving to external storage is not configured.

    Increase the maximum number of entries in the alarm archive settings within the WinCC flexible project, or configure automatic export of archived alarms to a network drive or memory card to preserve historical data.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart