• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2CA08-0AX0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2CA08-0AX0 WinCC flexible 2008

    € 2.032,52

    Reset
    Clear
    SKU: 6AV6381-2CA08-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2CA08-0AX0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI product line and is used to create visualization projects for operator panels across a wide range of automation applications.

    WinCC flexible 2008 offers a scalable engineering environment supporting the full range of Siemens SIMATIC HMI panels, from Micro Panels up to Multi Panels and PC-based runtime systems. The software provides tag-based licensing, project migration tools, and integration with STEP 7 for seamless PLC-HMI engineering. It supports communication via PROFIBUS, PROFINET, MPI, and Ethernet interfaces, and includes features such as alarm management, trend displays, recipe management, and user administration. The 2008 edition introduced enhanced performance, improved symbol libraries, and extended scripting capabilities using VBScript.

    WinCC flexible 2008 is widely used in manufacturing, process automation, machine building, and plant engineering environments. It is particularly suited for applications requiring centralized HMI project management across multiple panel types, including food and beverage processing, automotive assembly lines, packaging machinery, and water treatment facilities. Its compatibility with the broader Siemens TIA (Totally Integrated Automation) ecosystem makes it a practical choice for integrators working within established Siemens automation architectures.

    Technical Specifications

    Software Version WinCC flexible 2008
    License Type Engineering Software License
    Compatible Panel Families SIMATIC Micro Panels, OP/TP Series, Multi Panels, MP Series, PC Runtime
    Communication Interfaces PROFIBUS, PROFINET, MPI, Ethernet (TCP/IP)
    Scripting Support VBScript
    PLC Integration SIMATIC STEP 7
    Operating System Windows XP, Windows Vista, Windows 7 (32-bit)
    Project Migration Supports migration from ProTool and earlier WinCC flexible versions
    Alarm Management Included
    Recipe Management Included
    Trend Display Included
    User Administration Included
    Series/Product Family SIMATIC WinCC flexible

    Common Error Codes & System Events

    Event ID: 1000
    Project compilation error — one or more configuration errors detected during project build.
    Review the output log in the compiler window, correct all flagged configuration errors in the project, and recompile.
    Event ID: 2001
    Communication connection to PLC lost or unavailable during runtime.
    Check physical network connections, verify PLC IP address or MPI/PROFIBUS address settings in the connection editor, and confirm PLC is powered and online.
    Event ID: 3010
    Tag limit exceeded for the current license edition.
    Reduce the number of configured tags to within the licensed limit, or upgrade the WinCC flexible license to a higher tag count edition.
    Event ID: 4005
    Runtime license not found or invalid on target device.
    Verify that a valid WinCC flexible Runtime license is installed on the target panel or PC. Transfer the correct license using the Automation License Manager.
    Event ID: 5002
    Recipe data record read/write error.
    Check that the recipe data source (PLC tags or file system) is accessible and correctly configured. Verify tag connections and data types match between recipe and PLC.
    Event ID: 6001
    Script execution error — VBScript runtime fault detected.
    Open the script editor and review the flagged script for syntax or logic errors. Check that all referenced tags and objects exist in the project.
    Event ID: 7003
    Alarm logging failure — alarm archive cannot be written.
    Check available storage space on the target device, verify archive path configuration, and ensure the archive file is not locked by another process.

    Frequently Asked Questions

    Which Siemens HMI panels are compatible with WinCC flexible 2008?

    WinCC flexible 2008 supports the full range of SIMATIC HMI panels including Micro Panels (KTP series), Operator Panels (OP series), Touch Panels (TP series), and Multi Panels (MP series), as well as PC-based WinCC flexible Runtime systems.

    Can WinCC flexible 2008 projects be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible 2008 projects. Some manual rework may be required depending on the complexity of the project and the features used.

    What operating systems are supported for the engineering software installation?

    WinCC flexible 2008 supports installation on Windows XP, Windows Vista, and Windows 7 (32-bit). It is not natively supported on Windows 10 or later without compatibility measures.

    Does 6AV6381-2CA08-0AX0 include Runtime or only the engineering environment?

    The 6AV6381-2CA08-0AX0 is an engineering software package. Runtime licenses for PC-based systems are separate products and must be ordered independently if PC runtime operation is required.

    What communication protocols does WinCC flexible 2008 support?

    WinCC flexible 2008 supports PROFIBUS DP, PROFINET, MPI, and Ethernet (TCP/IP) communication protocols, enabling connectivity to SIMATIC S7-200, S7-300, S7-400, and other compatible controllers.

    Troubleshooting

    Project fails to compile with multiple errors after opening an older project

    Check the compiler output log for specific error types. Older projects created in earlier WinCC flexible versions may contain deprecated objects or tag configurations incompatible with the 2008 version.

    Run the project migration wizard from the Project menu to update the project structure. Resolve any remaining flagged errors manually in the affected screens or tag tables before recompiling.

    WinCC flexible 2008 software fails to install or crashes during installation

    Verify that the target PC meets the minimum system requirements and is running a supported 32-bit Windows operating system. Check for conflicting software such as other SIMATIC installations or antivirus interference.

    Disable antivirus software during installation, ensure all Windows updates are applied, and install any required prerequisites (such as .NET Framework and SIMATIC Common Services) before retrying the installation.

    Runtime connection to PLC shows 'No Connection' status on the panel

    Verify the communication settings in the WinCC flexible project, including the correct PLC address (IP, MPI node, or PROFIBUS address) and the selected communication driver. Check physical cabling and network switch status.

    Correct the PLC address and driver settings in the connection editor, recompile and download the project to the panel. Test connectivity using a STEP 7 or TIA Portal online connection to confirm the PLC is reachable on the same network.

    License error displayed when launching WinCC flexible engineering software

    Open the Siemens Automation License Manager (ALM) and check whether a valid WinCC flexible 2008 engineering license is present and not expired or transferred out.

    If the license is missing, use the Automation License Manager to transfer the license from the original storage medium (USB dongle or license disk) to the engineering PC. Contact Siemens support if the license has been lost or corrupted.

    Screens display incorrectly or objects are missing after project download to panel

    Check that the panel firmware version is compatible with the WinCC flexible 2008 project version. Mismatched firmware can cause rendering issues or missing object support.

    Update the panel firmware to the version recommended for WinCC flexible 2008 using the ProSave tool or via the panel's update function. Re-download the project after the firmware update is complete.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart