
Siemens 6AV6381-2CA08-0AK4 WinCC flexible 2008
€ 281,81
The Siemens 6AV6381-2CA08-0AK4 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. WinCC flexible is a PC-based HMI configuration and runtime software platform used to create, configure, and manage visualization projects for Siemens HMI panels and operator interfaces. This specific part number corresponds to the WinCC flexible 2008 standard edition, designed for engineering and project development on a Windows-based PC.
WinCC flexible 2008 provides a comprehensive engineering environment supporting the full range of Siemens HMI devices, from Micro Panels and Mobile Panels to Multi Panels and PC-based systems. The software includes a structured project editor, tag management, alarm logging, trend displays, recipe management, and script support via VBScript. It supports communication with Siemens S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Ethernet interfaces. The platform also supports multi-language project management, allowing visualization screens to be configured in multiple languages simultaneously.
WinCC flexible 2008 is used across a broad range of industrial automation applications including machine building, process automation, packaging machinery, and manufacturing lines. It is particularly suited for OEMs and system integrators who need to develop HMI projects for deployment on Siemens operator panels such as the TP177, MP277, and MP377 series. The software enables consistent project engineering across multiple panel types, reducing development time when migrating or scaling projects between different HMI hardware platforms.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| Edition | Standard |
| License Type | Single-user license |
| Host Platform | PC (Windows-based) |
| Supported HMI Devices | Micro Panels, Mobile Panels, Multi Panels, PC-based HMI |
| PLC Compatibility | S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces | MPI, PROFIBUS DP, Industrial Ethernet |
| Scripting Support | VBScript |
| Language Support | Multi-language project management |
| Series/Product Family | WinCC flexible |
| Certifications | CE |
Common Error Codes & System Events
- Error 1
- License not found or invalid license key detected during software startup
Verify that the license dongle (USB) is properly connected or that the software license is correctly installed using the Automation License Manager. Re-install the license if necessary. - Error 2
- Project compilation error due to inconsistent tag configuration
Open the project in the WinCC flexible editor, navigate to the tag table, and resolve any duplicate or incorrectly typed tag entries before recompiling. - Error 3
- Communication connection to PLC cannot be established
Check the configured communication driver and connection parameters (IP address, MPI address, or PROFIBUS address). Verify physical cabling and that the PLC is powered and in RUN mode. - Error 4
- Runtime transfer to HMI panel failed
Confirm that the HMI panel is in transfer mode, verify the transfer channel settings (Ethernet or USB), and ensure the PC firewall is not blocking the WinCC flexible transfer service. - Error 5
- Insufficient system resources during project compilation
Close other running applications to free RAM, ensure the PC meets minimum system requirements for WinCC flexible 2008, and attempt recompilation. - Error 6
- Incompatible project version detected when opening an existing project
Use the WinCC flexible migration tool to convert projects from earlier versions. Ensure the installed WinCC flexible version matches or is newer than the project version.
Frequently Asked Questions
Which HMI panels are supported by WinCC flexible 2008?
WinCC flexible 2008 supports the full range of Siemens HMI panels including Micro Panels (TP170micro), Mobile Panels (177, 277), Multi Panels (MP177, MP277, MP377), and PC-based HMI systems. It does not support the newer Comfort Panel series, which requires WinCC (TIA Portal).
Is WinCC flexible 2008 compatible with TIA Portal projects?
WinCC flexible 2008 is not natively compatible with TIA Portal. Projects created in WinCC flexible can be migrated to TIA Portal using the migration wizard included in TIA Portal, but the reverse is not supported.
What are the minimum PC system requirements for WinCC flexible 2008?
WinCC flexible 2008 requires a Windows XP SP3 or Windows 7 (32-bit) operating system, a Pentium IV processor at 1.5 GHz or higher, at least 512 MB RAM, and approximately 2 GB of free hard disk space.
Can WinCC flexible 2008 communicate with S7-1200 PLCs?
Yes, WinCC flexible 2008 supports communication with S7-1200 PLCs via Industrial Ethernet using the Ethernet communication driver, provided the correct connection parameters are configured in the project.
Does this license include runtime functionality?
The standard edition of WinCC flexible 2008 (6AV6381-2CA08-0AK4) is primarily an engineering license for project creation and configuration. Runtime functionality for PC-based HMI requires a separate WinCC flexible Runtime license.
Troubleshooting
Software fails to start and displays a license error message
Check whether the USB license dongle is connected or whether the license is installed correctly by opening the Automation License Manager and inspecting the license status.
Reconnect the USB dongle or use the Automation License Manager to transfer or repair the license. If the license is corrupted, contact Siemens support for license recovery.
Project cannot be transferred to the HMI panel
Verify the transfer channel configuration in WinCC flexible under Transfer Settings. Check that the HMI panel is set to transfer mode and that the network or USB connection is active.
Correct the IP address or communication channel settings, disable any PC firewall rules blocking the transfer port, and retry the transfer. Ensure the panel firmware version is compatible with the project.
Tags are not updating at runtime on the HMI panel
Check the communication connection status in the runtime diagnostics. Verify that the PLC is in RUN mode and that the tag addresses configured in WinCC flexible match the actual PLC data block or memory addresses.
Correct any mismatched tag addresses in the WinCC flexible tag table, recompile the project, and re-transfer it to the HMI panel. Confirm the communication driver is correctly configured.
WinCC flexible 2008 crashes or freezes during project compilation
Monitor PC resource usage during compilation using Task Manager. Check for low available RAM or CPU overload. Also inspect the project for overly complex scripts or a very large number of tags.
Increase available system RAM, close background applications, and simplify VBScripts where possible. Ensure the PC operating system and WinCC flexible service packs are fully up to date.
Existing project opens with missing screens or corrupted elements
Determine whether the project file was created in a different version of WinCC flexible. Check the project version information in the project properties dialog.
Use the WinCC flexible migration tool to upgrade the project to the 2008 version. If elements remain corrupted, restore from a backup or manually recreate the affected screens.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page



