• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2CA08-0AK3 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2CA08-0AK3 WinCC flexible 2008

    € 433,51

    Reset
    Clear
    SKU: 6AV6381-2CA08-0AK3 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2CA08-0AK3 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across the SIMATIC range.

    WinCC flexible 2008 offers a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and script-based automation. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet interfaces. It provides a scalable engineering environment compatible with a wide range of Siemens HMI hardware, from Micro Panels to Multi Panels, and supports project migration from earlier WinCC flexible versions. The software includes multilingual project support and integrated simulation tools for offline testing.

    WinCC flexible 2008 is widely used in manufacturing, process automation, machine building, and plant engineering applications. It is suitable for industries such as automotive, food and beverage, pharmaceuticals, and water treatment, where reliable operator visualization and control are required. The software enables machine builders and system integrators to develop standardized HMI solutions that can be deployed across multiple panel types and plant sections.

    Technical Specifications

    Software Version WinCC flexible 2008
    Software Type Engineering Software / HMI Configuration Tool
    Compatible PLC Families SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces Supported MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP)
    Compatible HMI Hardware SIMATIC Micro Panels, OP/TP Series, Multi Panels, PC-based HMI
    Operating System Windows XP, Windows Vista, Windows 7 (32/64-bit)
    Series/Product Family SIMATIC WinCC flexible
    License Type Single-user software license
    Project Migration Supports migration from WinCC flexible 2004/2005/2007
    Language Support Multilingual project engineering
    Simulation Integrated offline simulator included
    Certifications CE

    Common Error Codes & System Events

    Event ID: 1000000
    General runtime error during project startup. The WinCC flexible runtime could not initialize correctly.
    Check the project configuration for missing tags or corrupted project files. Reinstall the runtime software if the issue persists.
    Event ID: 1000020
    Communication error between HMI and PLC. The configured connection to the controller cannot be established.
    Verify network or bus cabling, check PLC address settings, and confirm that the communication driver is correctly configured in the project.
    Event ID: 1000030
    Tag limit exceeded. The number of configured tags exceeds the licensed tag count for the runtime.
    Reduce the number of tags in the project or upgrade the runtime license to a higher tag count variant.
    Event ID: 1000040
    License not found or invalid. The software cannot detect a valid license for WinCC flexible runtime or engineering.
    Check that the license dongle (USB or Automation License Manager) is correctly installed and recognized. Transfer or repair the license using Siemens Automation License Manager.
    Event ID: 1000050
    Project transfer error. A project download from the engineering PC to the HMI panel failed.
    Check the transfer connection (USB, Ethernet, or MPI), ensure the panel is in transfer mode, and verify that the project is compiled without errors before transfer.
    Event ID: 1000060
    Alarm logging error. The alarm system could not write to the configured alarm log or archive.
    Check available storage space on the target device, verify alarm log configuration, and ensure the archive path is accessible.
    Event ID: 1000070
    Recipe data error. A recipe read or write operation failed during runtime.
    Verify recipe configuration, check that the associated PLC tags are online and accessible, and confirm that storage media for recipe data is available and not write-protected.
    Event ID: 1000080
    Script execution error. A VB script configured in the project encountered a runtime error.
    Review the script logic in the WinCC flexible engineering environment, check for invalid tag references or syntax errors, and test using the integrated simulator.

    Frequently Asked Questions

    Which PLC families are compatible with WinCC flexible 2008?

    WinCC flexible 2008 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet. Third-party controllers may also be supported through OPC or specific communication drivers.

    What operating systems does WinCC flexible 2008 support?

    WinCC flexible 2008 is compatible with Windows XP, Windows Vista, and Windows 7 in both 32-bit and 64-bit editions. It is not officially supported on Windows 10 or later without compatibility workarounds.

    Can WinCC flexible 2008 projects be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that allows WinCC flexible projects to be imported and converted. However, some manual rework may be required depending on the complexity of the original project.

    Is a hardware dongle required to run WinCC flexible 2008?

    WinCC flexible 2008 requires a valid license managed through the Siemens Automation License Manager (ALM). The license can be stored on a USB dongle or transferred to the PC hard drive depending on the license type.

    Which SIMATIC HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports a wide range of SIMATIC HMI hardware including Micro Panels (KTP series), Operator Panels (OP series), Touch Panels (TP series), and Multi Panels (MP series), as well as PC-based runtime environments.

    Troubleshooting

    WinCC flexible 2008 engineering software fails to install or crashes during installation

    Check Windows compatibility settings and verify that the operating system version is supported. Review the installation log files for specific error codes.

    Ensure the PC meets the minimum system requirements, disable antivirus software temporarily during installation, and run the installer with administrator privileges. Apply any required Windows service packs before installation.

    License not recognized after installation

    Open the Siemens Automation License Manager and check whether the license is listed and valid. Verify that the USB dongle is detected by the operating system.

    Reinstall the Automation License Manager, reconnect the USB dongle, or use the ALM repair function to restore a corrupted license. Contact Siemens license support if the license cannot be recovered.

    Project cannot be transferred to the HMI panel

    Verify the transfer connection type (USB, Ethernet, or MPI) and confirm the panel is set to transfer mode. Check that the project compiles without errors in the engineering environment.

    Reconfigure the transfer settings in WinCC flexible, ensure the correct IP address or bus address is set, and retry the transfer. If using Ethernet, confirm network connectivity with a ping test.

    Runtime simulation does not start or freezes

    Check that the simulation feature is enabled in the project settings and that all referenced tags are correctly configured. Review the Windows event log for application errors.

    Recompile the project, clear temporary simulation files, and restart the WinCC flexible engineering software. Ensure no conflicting runtime instances are running in the background.

    Communication to PLC drops intermittently during runtime

    Monitor the connection status in the WinCC flexible runtime diagnostics. Check physical cabling, bus termination resistors on PROFIBUS, and network switch settings for Ethernet connections.

    Replace faulty cables or connectors, verify correct PROFIBUS termination at both ends of the bus, and adjust Ethernet switch settings to disable energy-saving modes that may interrupt communication.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart