Siemens 6AV6381-2CB08-0AK3 WinCC flexible 2008
€ 740,79
The Siemens 6AV6381-2CB08-0AK3 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for creating and managing HMI (Human-Machine Interface) projects across a wide range of Siemens panels and PC-based systems. It is designed for use with the SIMATIC HMI product line and integrates tightly with the Siemens TIA (Totally Integrated Automation) ecosystem.
WinCC flexible 2008 offers a scalable engineering environment supporting configuration of operator panels from Micro Panels up to multi-panel and multi-user systems. The software supports communication via PROFIBUS, PROFINET, MPI, and Ethernet interfaces, enabling connectivity to SIMATIC S7-200, S7-300, S7-400, and other compatible controllers. It includes features such as faceplates, script support (VBScript), alarm management, trend displays, recipe management, and user administration. The 2008 edition introduced improved project migration tools and enhanced diagnostic capabilities.
WinCC flexible 2008 is widely used in manufacturing automation, process control, and machine building applications across industries such as automotive, food and beverage, pharmaceuticals, and energy. It is suitable for OEMs and system integrators who require a consistent engineering platform across multiple HMI hardware variants. The software's scalability allows it to serve both small standalone machine panels and complex distributed visualization systems.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| Software Type | Engineering Software / HMI Configuration Tool |
| Compatible HMI Hardware | SIMATIC Micro Panels, OP/TP Series, MP Series, PC-based HMI |
| Compatible Controllers | SIMATIC S7-200, S7-300, S7-400, S7-1200 (with restrictions) |
| Communication Interfaces | PROFIBUS, PROFINET, MPI, Ethernet, USB |
| Scripting Support | VBScript |
| Operating System | Windows XP, Windows Vista, Windows 7 (32-bit) |
| License Type | Single-user software license |
| Alarm Management | Supported |
| Recipe Management | Supported |
| Trend Display | Supported |
| User Administration | Supported |
| Project Migration | Supported from earlier WinCC flexible versions |
| Series/Product Family | SIMATIC WinCC flexible |
Common System Event Codes
- Event ID: 110000
- Communication error between WinCC flexible runtime and the connected PLC. The HMI cannot establish or maintain a connection to the controller.
Check physical communication cable and interface settings. Verify PLC address, network parameters, and that the PLC is in RUN mode. Confirm correct driver is selected in the project. - Event ID: 110001
- Connection to PLC interrupted during runtime operation.
Check network or fieldbus cabling for faults. Verify PLC is powered and operational. Restart the HMI runtime and re-establish the connection. - Event ID: 120000
- Tag read error. The runtime was unable to read the value of one or more configured tags from the PLC.
Verify the tag address exists in the PLC program and the data block is not write-protected. Check communication connection status and tag configuration in the project. - Event ID: 130000
- Recipe data error. A recipe transfer to or from the PLC failed.
Check that the recipe data record structure matches the PLC data block layout. Verify available memory on the HMI device and confirm communication is active. - Event ID: 140000
- Alarm logging error. The system was unable to write alarm entries to the configured alarm log.
Check available storage space on the HMI device or connected storage medium. Verify the alarm log file path and access permissions in the project configuration. - Event ID: 170000
- Script runtime error. A VBScript function executed in the project encountered an error during runtime.
Review the VBScript code for syntax or logic errors. Use the WinCC flexible diagnostic tools to identify the specific script and line causing the fault. Correct and recompile the project. - Event ID: 180000
- Project download error. Transfer of the compiled project to the HMI panel failed.
Check the transfer cable or network connection between the engineering PC and the HMI device. Ensure the HMI is in transfer mode and that the correct transfer channel is configured in WinCC flexible.
Frequently Asked Questions
Which operating systems are supported for installing WinCC flexible 2008?
WinCC flexible 2008 supports Windows XP (32-bit), Windows Vista (32-bit), and Windows 7 (32-bit). It is not compatible with 64-bit operating systems or Windows 10/11.
Can WinCC flexible 2008 projects be migrated to TIA Portal WinCC?
Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible 2008 projects. However, some features and scripts may require manual rework after migration due to differences between the platforms.
Which Siemens HMI panels are supported by WinCC flexible 2008?
WinCC flexible 2008 supports the full range of SIMATIC HMI panels including Micro Panels (KTP series), OP/TP operator panels, Multi Panels (MP series), and PC-based runtime systems running WinCC flexible Runtime.
Does WinCC flexible 2008 support communication with S7-1200 PLCs?
S7-1200 support in WinCC flexible 2008 is limited and was not part of the original release. Siemens recommends using TIA Portal for projects combining S7-1200 controllers with modern HMI panels.
What is the difference between WinCC flexible Engineering and WinCC flexible Runtime?
WinCC flexible Engineering is the PC-based software used to create and configure HMI projects, while WinCC flexible Runtime is the software that executes the project on a PC-based HMI system. Panel-based HMIs have their runtime firmware built in and do not require a separate Runtime license.
Troubleshooting
WinCC flexible 2008 fails to install on the engineering PC
Check the operating system version and architecture. WinCC flexible 2008 requires a 32-bit Windows environment. Also verify that Microsoft .NET Framework prerequisites and required Visual C++ redistributables are installed.
Install WinCC flexible 2008 on a supported 32-bit Windows XP, Vista, or Windows 7 system. Ensure all prerequisite software listed in the installation guide is installed before running the setup. Disable antivirus software temporarily during installation if setup files are being blocked.
Project cannot be transferred to the HMI panel
Verify the transfer channel settings in WinCC flexible match the physical connection being used (USB, Ethernet, or serial). Confirm the HMI panel is set to transfer mode and is reachable from the engineering PC.
Set the HMI panel to transfer mode via its Start Center or loader menu. Match the transfer channel configuration in WinCC flexible to the actual interface used. For Ethernet transfers, ensure both devices are on the same subnet and no firewall is blocking the connection.
Runtime communication alarms appear continuously on the HMI panel after project startup
Check the PLC connection settings in the project, including the PLC address, interface type, and slot/rack number. Use the WinCC flexible connection diagnostics to identify which connection is failing.
Correct the PLC address and interface parameters in the WinCC flexible project. Recompile and re-download the project to the panel. Verify physical cabling between the HMI and PLC and confirm the PLC is in RUN mode.
Compiled project size exceeds the available memory on the target HMI panel
Review the project in WinCC flexible and check the memory usage indicator. Large numbers of graphics, high-resolution images, or excessive recipe data are common causes of oversized projects.
Optimize graphics by reducing image resolution and reusing symbols via the library. Reduce the number of stored recipe data records or move logging data to an external memory card. Select a target HMI panel with sufficient flash memory for the project requirements.
VBScript functions do not execute correctly during runtime
Open the project in WinCC flexible and review the script editor for syntax errors. Check the system event log on the HMI for Event ID 170000 entries that identify the failing script.
Correct any syntax or logic errors in the VBScript code. Ensure that tag names referenced in scripts exactly match those defined in the tag editor. Recompile the project and transfer it to the HMI panel after making corrections.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page