• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2CA07-5AK3 WinCC flexible 2007
    Awaiting product image

    Siemens 6AV6381-2CA07-5AK3 WinCC flexible 2007

    € 276,00

    Reset
    Clear
    SKU: 6AV6381-2CA07-5AK3 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2CA07-5AK3 is a software license for WinCC flexible 2007 Compact, part of Siemens' WinCC flexible engineering software family. WinCC flexible is a PC-based HMI configuration and runtime software platform used to create visualization projects for Siemens HMI panels and operator interfaces. This specific part number corresponds to the Compact edition of WinCC flexible 2007, which is designed for configuring smaller-scale HMI applications on panels such as the OP/TP 170, TP 177, and similar Siemens Micro and Compact panel families.

    WinCC flexible 2007 Compact provides an engineering environment for designing screens, alarms, tags, recipes, and trend displays for compatible HMI hardware. The software integrates with the Siemens SIMATIC engineering ecosystem and supports communication with S7-200, S7-300, and S7-400 PLCs via MPI, PROFIBUS DP, and Ethernet interfaces. The Compact edition supports a limited tag count and screen number compared to the Standard and Advanced editions, making it suitable for straightforward HMI projects. The software runs on Windows XP and Windows Vista operating systems and includes a simulator for offline project testing without physical hardware.

    WinCC flexible 2007 Compact is typically used in small to medium manufacturing cells, packaging machinery, material handling equipment, and process control panels where a cost-effective HMI engineering tool is required. It is well suited for OEMs and system integrators building machines with Siemens Micro and Compact panel hardware. The software's tight integration with STEP 7 and the broader SIMATIC environment simplifies project engineering and reduces commissioning time in industrial automation applications.

    Technical Specifications

    Software Edition Compact
    Software Version WinCC flexible 2007
    License Type Single-user license
    Compatible HMI Panels Micro Panels, Compact Panels (OP/TP 170, TP 177, OP 177, etc.)
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400
    Communication Interfaces MPI, PROFIBUS DP, Ethernet (TCP/IP)
    Operating System Windows XP, Windows Vista
    Tag Count Limited (Compact edition)
    Offline Simulation Included
    Integration STEP 7, SIMATIC Manager
    Language Support Multilingual project engineering
    Series/Product Family WinCC flexible

    Common Error Codes & System Events

    Event ID: 1000
    Project file could not be opened or is corrupted
    Verify the project file integrity, restore from backup, or recreate the project. Ensure the correct WinCC flexible version is installed.
    Event ID: 1010
    License not found or license key invalid
    Check that the software license dongle (USB or SIM key) is properly connected. Verify the license using the Siemens Automation License Manager (ALM).
    Event ID: 1020
    Communication connection to HMI panel failed during transfer
    Check the physical cable connection between the PC and HMI panel. Verify the correct communication interface and transfer settings are configured in the project.
    Event ID: 1030
    Tag limit exceeded for Compact edition
    Reduce the number of configured tags to within the Compact edition limit, or upgrade the license to WinCC flexible Standard or Advanced edition.
    Event ID: 1040
    Incompatible HMI device type selected for project
    Verify the target HMI panel type matches the device selected during project creation. Migrate the project to the correct device type if necessary.
    Event ID: 1050
    Runtime simulation error — project could not be started in simulator
    Check for missing or misconfigured tags and screens. Ensure all referenced connections and data types are valid before launching the simulator.
    Event ID: 1060
    Operating system compatibility error
    Verify that the PC operating system meets the minimum requirements (Windows XP SP2 or Windows Vista). Reinstall the software if the issue persists.

    Frequently Asked Questions

    Which HMI panels are supported by WinCC flexible 2007 Compact?

    WinCC flexible 2007 Compact supports Siemens Micro Panels and Compact Panels, including the OP 73, TP 170, OP 170, TP 177, and OP 177 series. It does not support Multi Panels or PC-based runtime systems, which require the Standard or Advanced edition.

    What PLCs can be configured for communication in WinCC flexible 2007 Compact?

    The software supports communication with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI, PROFIBUS DP, and Ethernet (TCP/IP) interfaces. Third-party PLC drivers may be limited compared to higher editions.

    Is a hardware dongle required to run WinCC flexible 2007 Compact?

    Yes, WinCC flexible 2007 requires a valid Siemens software license managed through the Automation License Manager (ALM). The license is typically tied to a USB dongle or a license key file.

    Can WinCC flexible 2007 projects be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible projects. However, manual adjustments are typically required after migration due to differences in functionality between the platforms.

    What operating systems are compatible with WinCC flexible 2007 Compact?

    WinCC flexible 2007 Compact is compatible with Windows XP (SP2 or later) and Windows Vista. It is not officially supported on Windows 7 or later without additional compatibility measures.

    Troubleshooting

    Software fails to start after installation and displays a license error

    Open the Siemens Automation License Manager (ALM) and check whether a valid license for WinCC flexible 2007 Compact is present and active.

    Connect the USB license dongle if not already attached, or transfer the license to the engineering PC using the ALM. If the license is missing, contact Siemens for license recovery.

    Project transfer to HMI panel fails with a connection error

    Check the physical cable between the PC and the HMI panel. Verify the transfer settings in WinCC flexible match the panel's configured interface (MPI address, baud rate, or Ethernet IP address).

    Correct the communication parameters in the transfer dialog, replace the cable if faulty, and ensure the HMI panel is in transfer mode before initiating the download.

    Configured tags are not updating during runtime simulation

    Check that the tag connections reference valid PLC data areas and that the correct communication driver is selected. Verify that tag addresses are within the supported range for the Compact edition.

    Correct any invalid tag addresses, ensure the communication driver is properly configured, and restart the simulation. If tag limits are exceeded, reduce the tag count or upgrade the license edition.

    WinCC flexible 2007 installation fails on the PC

    Verify that the PC meets the minimum hardware and operating system requirements. Check for conflicting software or previously installed WinCC flexible versions that may interfere with the installation.

    Uninstall any previous WinCC flexible versions using the Siemens uninstall tool, ensure the OS is Windows XP SP2 or Windows Vista, and re-run the installation with administrator privileges.

    Alarm displays in the project do not show alarm texts correctly on the HMI panel

    Check the alarm configuration in WinCC flexible for missing or incorrectly assigned alarm text entries. Verify that the correct language is set as the active runtime language.

    Review and correct all alarm text entries in the alarm editor, ensure the active language matches the panel's configured runtime language, and retransfer the project to the HMI panel.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart