• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2CA07-5AH0 WinCC flexible 2007
    Awaiting product image

    Siemens 6AV6381-2CA07-5AH0 WinCC flexible 2007

    € 1.016,00

    Reset
    Clear
    SKU: 6AV6381-2CA07-5AH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2CA07-5AH0 is a software license for WinCC flexible 2007, part of Siemens' WinCC flexible SCADA and HMI engineering software family. This package provides the engineering environment used to configure, program, and commission Siemens HMI panels and visualization systems. It is designed for use on standard engineering PCs running compatible Windows operating systems.

    WinCC flexible 2007 offers a comprehensive set of tools for creating HMI projects, including tag management, alarm configuration, trend displays, recipe management, and script-based automation. The software supports a wide range of Siemens HMI hardware targets, including the OP, TP, MP, and Mobile Panel series. Integration with Siemens STEP 7 and SIMATIC Manager is supported, enabling consistent data exchange and symbol sharing between PLC and HMI projects. The package includes runtime simulation capabilities, allowing engineers to test and validate HMI screens without physical hardware.

    WinCC flexible 2007 is used across manufacturing, process automation, and machine building industries wherever Siemens HMI panels are deployed. It is particularly common in applications involving SIMATIC S7-300 and S7-400 PLC systems paired with Siemens operator panels. The software is suitable for both small standalone machine HMI projects and larger distributed visualization systems requiring multi-panel configurations.

    Technical Specifications

    Software Version WinCC flexible 2007
    Software Type HMI Engineering Software
    License Type Single-user license
    Compatible HMI Hardware OP, TP, MP, Mobile Panel series (Siemens SIMATIC HMI)
    PLC Integration SIMATIC S7-300, S7-400 via STEP 7 / SIMATIC Manager
    Communication Protocols PROFIBUS, MPI, PROFINET, Ethernet
    Runtime Simulation Included
    Alarm Management Supported
    Recipe Management Supported
    Trend Display Supported
    Scripting VBScript support
    Series/Product Family WinCC flexible

    Common Error Codes and System Events

    Error 1000
    License not found or invalid license key detected during software startup
    Verify that the correct license key is installed using the Siemens Automation License Manager (ALM). Reinstall the license if necessary.
    Error 1001
    License has expired or is no longer valid for the installed software version
    Renew or upgrade the license through Siemens. Use the ALM tool to check license validity and expiry date.
    Compiler Error
    Project compilation fails due to inconsistent tag references or missing symbols
    Check all tag connections and symbol imports from STEP 7. Resolve any broken references in the tag editor before recompiling.
    Communication Error
    HMI panel cannot establish connection to the configured PLC during runtime or simulation
    Verify communication settings including PLC address, interface type (MPI/PROFIBUS/Ethernet), and cable connections. Check that the PLC is in RUN mode.
    Transfer Error
    Project transfer to HMI panel fails during download
    Confirm the transfer channel settings match the physical connection (USB, Ethernet, or serial). Ensure the panel is in Transfer mode and that no firewall is blocking the connection.
    Runtime Simulation Error
    Simulation fails to start or crashes unexpectedly on the engineering PC
    Verify that the PC meets minimum system requirements and that all required WinCC flexible runtime components are installed. Check Windows Event Viewer for additional diagnostic information.
    Version Mismatch Warning
    Project was created with a different version of WinCC flexible than the installed software
    Migrate the project using the built-in migration wizard, or install the correct version of WinCC flexible that matches the original project version.

    Frequently Asked Questions

    What HMI panels are supported by WinCC flexible 2007?

    WinCC flexible 2007 supports a wide range of Siemens SIMATIC HMI panels including the OP 77, TP 177, MP 277, MP 377, and Mobile Panel series, among others. Refer to the Siemens compatibility list for the full range of supported devices.

    Is WinCC flexible 2007 compatible with STEP 7?

    Yes, WinCC flexible 2007 integrates with Siemens STEP 7 and SIMATIC Manager, allowing shared symbol tables and tag imports between PLC and HMI projects.

    Can WinCC flexible 2007 simulate HMI projects without physical hardware?

    Yes, the software includes a runtime simulation function that allows engineers to test and validate HMI screens on the engineering PC without requiring a physical HMI panel.

    What operating systems are supported?

    WinCC flexible 2007 is designed for use on Windows XP and Windows Vista operating systems. Compatibility with later Windows versions may require additional patches or is not officially supported.

    What communication interfaces does WinCC flexible 2007 support for panel connectivity?

    The software supports MPI, PROFIBUS, and Ethernet/PROFINET communication interfaces for connecting to Siemens PLCs and transferring projects to HMI panels.

    Troubleshooting

    Software fails to start after installation

    Check the Automation License Manager (ALM) to confirm the license is correctly installed and valid. Review Windows Event Viewer for application errors related to WinCC flexible startup.

    Reinstall the license using the ALM tool. If the issue persists, perform a repair installation of WinCC flexible 2007 from the original installation media.

    Project cannot be transferred to the HMI panel

    Verify the transfer channel configuration in the project settings matches the physical connection type (USB, Ethernet, or serial/MPI). Confirm the HMI panel is set to Transfer mode.

    Correct the transfer channel settings, ensure the panel is in Transfer mode, and disable any PC firewall rules that may block the transfer port. Retry the download.

    Tags imported from STEP 7 are missing or show errors

    Check that the STEP 7 project is saved and compiled before importing symbols into WinCC flexible. Verify that the correct PLC program block is referenced.

    Recompile the STEP 7 project, then re-import the symbol table into WinCC flexible. Manually reassign any tags that remain unresolved.

    Runtime simulation crashes or does not display screens correctly

    Confirm that the engineering PC meets the minimum hardware requirements for WinCC flexible 2007 runtime simulation. Check for missing or corrupted runtime components.

    Reinstall the WinCC flexible runtime components from the installation package. Ensure the PC has sufficient RAM and that DirectX drivers are up to date.

    Communication between HMI panel and PLC drops intermittently during operation

    Check the physical cable connections and network topology. Verify the PLC address and communication parameters configured in the HMI project match the actual PLC settings.

    Replace suspect cables, verify termination resistors on PROFIBUS networks, and confirm that the PLC communication parameters (MPI address, baud rate) match the HMI configuration.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart