• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2CA07-5AK4 WinCC flexible 2007
    Awaiting product image

    Siemens 6AV6381-2CA07-5AK4 WinCC flexible 2007

    € 190,00

    Reset
    Clear
    SKU: 6AV6381-2CA07-5AK4 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2CA07-5AK4 is a software license for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the broader SIMATIC HMI software portfolio and is used to create visualization projects for industrial automation systems.

    WinCC flexible 2007 offers a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and scripting capabilities via VBScript. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS, and Ethernet interfaces. It includes a library of pre-built faceplates and graphic objects, and supports multi-language project configuration for international deployments. The 2007 edition introduced improved performance, extended device support, and enhanced diagnostic functions compared to earlier versions.

    WinCC flexible 2007 is widely used in manufacturing, process automation, packaging machinery, and building automation applications. It is suitable for configuring operator panels ranging from small Micro Panels to multi-touch comfort panels and PC-based SCADA stations. Industries such as automotive, food and beverage, pharmaceuticals, and water treatment rely on this software to build robust HMI solutions integrated with Siemens SIMATIC controller platforms.

    Technical Specifications

    Software Version WinCC flexible 2007
    Series/Product Family SIMATIC WinCC flexible
    License Type Single-user engineering license
    Supported PLC Families SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP)
    Scripting Support VBScript
    Operating System Windows XP, Windows Vista, Windows 7 (32-bit)
    Supported HMI Devices SIMATIC Micro Panels, OP/TP series, Multi Panels, PC-based HMI
    Project Languages Multi-language support (up to 32 languages per project)
    Alarm Management Integrated alarm logging and display
    Recipe Management Supported
    Trend Display Supported
    Certifications CE

    Common Error Codes & System Events

    Event ID: 1000
    Runtime startup failure — WinCC flexible Runtime could not be initialized on the target device.
    Check that the correct Runtime version is installed on the panel or PC. Verify project compatibility with the Runtime version and re-download the project.
    Event ID: 2501
    Communication error — No connection established to the configured PLC.
    Verify PLC address settings and communication cable connections. Check MPI/PROFIBUS baud rate settings and ensure the PLC is powered and in RUN mode.
    Event ID: 3000
    Tag read/write error — A configured tag could not be read from or written to the PLC.
    Verify the tag address in the project matches the actual PLC data block or memory address. Check PLC program for address conflicts.
    Event ID: 4010
    License not found — No valid WinCC flexible engineering license detected.
    Ensure the USB license dongle (SIMATIC Automation License Manager) is connected. Verify the license is correctly transferred using the Automation License Manager tool.
    Event ID: 5200
    Project download failed — Transfer of the compiled project to the HMI panel was unsuccessful.
    Check the transfer cable or Ethernet connection between the engineering PC and the HMI panel. Ensure the panel is in Transfer mode and the correct transfer channel is selected.
    Event ID: 6100
    Overflow of alarm buffer — The alarm buffer on the HMI device has reached its maximum capacity.
    Acknowledge and clear pending alarms. Increase the alarm buffer size in the project settings or configure alarm archiving to an external storage medium.
    Event ID: 7300
    Script runtime error — A VBScript function encountered an error during execution.
    Review the VBScript code in the project for syntax errors or invalid object references. Use the WinCC flexible simulator to debug scripts before downloading to the panel.

    Frequently Asked Questions

    Which PLC families are compatible with WinCC flexible 2007?

    WinCC flexible 2007 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet interfaces.

    What operating systems are supported for the engineering station?

    WinCC flexible 2007 is compatible with Windows XP, Windows Vista, and Windows 7 (32-bit). It is not natively supported on 64-bit operating systems without compatibility settings.

    Can WinCC flexible 2007 projects be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible 2007 projects, though some manual rework may be required for advanced scripting and device-specific configurations.

    Is a hardware dongle required to run WinCC flexible 2007?

    Yes, a valid license managed through the Siemens Automation License Manager (ALM) is required. The license can be stored on a USB dongle or transferred to the engineering PC's hard drive.

    What is the maximum number of tags supported in a WinCC flexible 2007 project?

    The number of supported tags depends on the license edition (Micro, Compact, Standard, Advanced). The Advanced edition supports up to 100,000 tags for PC-based Runtime applications.

    Troubleshooting

    WinCC flexible 2007 fails to install on the engineering PC

    Check the Windows version and service pack level. Verify that no conflicting Siemens software versions are installed and that the user account has administrator privileges.

    Ensure the PC runs a supported 32-bit Windows OS (XP SP3, Vista SP2, or Windows 7). Uninstall conflicting software versions and run the installer as administrator. Install all required Microsoft redistributables listed in the release notes.

    No communication between HMI panel and PLC after project download

    Check the physical connection (MPI cable, PROFIBUS cable, or Ethernet cable). Verify the PLC station address and baud rate configured in the WinCC flexible project match the actual PLC settings.

    Correct the PLC address and communication parameters in the project and re-download. Replace or reseat the communication cable. For Ethernet connections, verify IP address settings on both the panel and PLC.

    License error displayed when opening WinCC flexible 2007

    The Automation License Manager cannot detect a valid license. Check if the USB dongle is connected or if the software license is present on the local hard drive using the ALM tool.

    Insert the USB license dongle or use the Automation License Manager to transfer a valid license to the engineering PC. If the license is corrupted, contact Siemens support for license recovery.

    Project simulation fails or crashes during testing

    Check for VBScript errors in the output window. Verify that all referenced tags and screens exist in the project and that there are no circular references in scripts.

    Correct any script errors identified in the simulation log. Ensure all tag connections are valid and that the simulation PC meets the minimum hardware requirements for WinCC flexible 2007.

    Alarm display on HMI panel shows no alarms despite PLC fault conditions

    Verify that the alarm tags are correctly mapped to the PLC bit addresses. Check that the alarm class and trigger bit configuration in the project match the PLC program logic.

    Review and correct the alarm tag addresses in the WinCC flexible project. Ensure the PLC program sets the correct memory bits when fault conditions occur. Re-download the project and test alarm triggering.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart