• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BT07-5AV0 WinCC flexible 2007
    Awaiting product image

    Siemens 6AV6381-2BT07-5AV0 WinCC flexible 2007

    € 2.495,00

    Reset
    Clear
    SKU: 6AV6381-2BT07-5AV0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BT07-5AV0 is a software license for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and deploying human-machine interface (HMI) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create, configure, and manage visualization projects.

    WinCC flexible 2007 offers a scalable engineering environment supporting a wide range of Siemens HMI hardware, from Micro Panels to Multi Panels and PC-based runtime systems. The software includes libraries of pre-built faceplates, tag management, alarm logging, trend displays, and recipe management. It supports communication via PROFIBUS, PROFINET, MPI, and Ethernet interfaces, and integrates directly with SIMATIC S7-200, S7-300, and S7-400 PLCs. The platform supports multi-language project engineering and offers simulation capabilities for offline testing.

    WinCC flexible 2007 is widely used in manufacturing, process automation, and machine building industries where Siemens HMI panels are deployed. It is suitable for applications requiring centralized visualization engineering across multiple panel types, including packaging machinery, conveyor systems, and production lines. The software's compatibility with the broader SIMATIC automation ecosystem makes it a standard tool for system integrators and OEMs working with Siemens control hardware.

    Technical Specifications

    Software Version WinCC flexible 2007
    Series/Product Family SIMATIC WinCC flexible
    Software Type Engineering Software (Configuration + Runtime)
    Supported HMI Hardware Micro Panels, Mobile Panels, Operator Panels, Multi Panels, PC-based HMI
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400, S7-1200 (via drivers)
    Communication Interfaces MPI, PROFIBUS DP, PROFINET, Ethernet (TCP/IP)
    Operating System Windows XP, Windows Vista, Windows 7
    Alarm Management Supported (discrete and analog alarms with logging)
    Recipe Management Supported
    Trend Display Supported
    Multi-language Support Yes, up to 32 languages per project
    Simulation Offline simulation supported without physical hardware
    Certifications CE

    Common Error Codes and System Events

    Event ID: 1000001
    Communication error between engineering software and connected HMI device during download or upload.
    Check the communication cable and interface settings. Verify the correct COM port or network address is configured in the project settings. Restart the transfer session.
    Event ID: 1000002
    Project compilation error due to invalid tag configuration or missing driver assignment.
    Open the project in WinCC flexible, navigate to the tag table, and resolve all highlighted errors. Ensure all tags are assigned to a valid communication driver and address.
    Event ID: 1000003
    License not found or license key invalid during software startup.
    Verify the license dongle (USB or software license) is correctly installed. Use the Siemens Automation License Manager (ALM) to check license status and transfer or repair the license if necessary.
    Event ID: 1000004
    Runtime transfer failed — target HMI device storage is full or incompatible runtime version.
    Check available memory on the target HMI panel. Ensure the runtime version on the panel matches the version supported by WinCC flexible 2007. Delete unused projects from the panel if storage is insufficient.
    Event ID: 1000005
    Inconsistent project data detected during project open or migration from an older WinCC flexible version.
    Use the built-in project migration wizard to convert the project to WinCC flexible 2007 format. Back up the original project before migration and resolve any reported inconsistencies.
    Event ID: 1000006
    Driver connection failure — no communication established between HMI runtime and PLC.
    Verify PLC address settings in the project connections editor. Check physical wiring and network configuration. Confirm the PLC is in RUN mode and the correct communication driver is selected.

    Frequently Asked Questions

    What type of software is the Siemens 6AV6381-2BT07-5AV0?

    It is an engineering software package for WinCC flexible 2007, used to configure and deploy HMI visualization projects on Siemens SIMATIC HMI panels and PC-based runtime systems.

    Which Siemens HMI panels are compatible with WinCC flexible 2007?

    WinCC flexible 2007 supports a broad range of Siemens HMI hardware including Micro Panels (TP 170, OP 170), Mobile Panels, Multi Panels (MP 277, MP 377), and PC-based systems running WinCC flexible Runtime.

    Which PLCs can communicate with projects created in WinCC flexible 2007?

    Projects can communicate with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI, PROFIBUS DP, or Ethernet. Third-party PLCs may also be supported through available OPC or driver interfaces.

    Does WinCC flexible 2007 require a hardware dongle for licensing?

    Licensing is managed through the Siemens Automation License Manager (ALM). The license can be stored on a USB dongle or transferred to a hard disk, depending on the license type supplied with this part number.

    Can WinCC flexible 2007 projects be migrated to TIA Portal (WinCC Advanced)?

    Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible projects, though some manual rework may be required for complex projects or unsupported features.

    Troubleshooting

    Software fails to start and displays a license error message

    Open the Siemens Automation License Manager (ALM) and check whether a valid WinCC flexible 2007 license is present and not expired or damaged.

    Reconnect the USB license dongle if used, or use ALM to repair or transfer the license from backup. Contact Siemens license support if the license key is corrupted.

    Project download to HMI panel fails with a communication timeout

    Check the transfer cable connection (USB, MPI, or Ethernet) and verify the HMI panel is in Transfer mode. Confirm the correct interface and baud rate are set in the WinCC flexible transfer settings.

    Switch the HMI panel manually to Transfer mode, verify cable integrity, and retry the download. For Ethernet transfers, ensure the PC and panel are on the same subnet and no firewall is blocking the connection.

    Compilation errors appear when building the project

    Review the output window in WinCC flexible for specific error messages. Common causes include unassigned tags, missing graphics objects, or invalid PLC address formats.

    Navigate to each reported error in the project, correct tag addresses, assign all required communication connections, and recompile the project until no errors remain.

    HMI panel shows 'No connection to PLC' at runtime after project transfer

    Verify the PLC address configured in the WinCC flexible connections editor matches the actual PLC MPI or IP address. Check that the communication cable is connected and the PLC is powered and in RUN mode.

    Correct the PLC address in the project connections, re-download the project to the panel, and confirm physical communication wiring. For PROFIBUS, verify baud rate settings match on both devices.

    WinCC flexible 2007 crashes or freezes during project editing on Windows 7

    Check Windows Event Viewer for application crash logs referencing WinCC flexible components. Verify that all required service packs and patches for WinCC flexible 2007 are installed.

    Install the latest Siemens-recommended updates and service packs for WinCC flexible 2007. Ensure the PC meets minimum hardware requirements and that no conflicting software (antivirus, firewall) is interfering with the application.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart