• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BT07-5AH0 WinCC flexible 2007
    Awaiting product image

    Siemens 6AV6381-2BT07-5AH0 WinCC flexible 2007

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6381-2BT07-5AH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BT07-5AH0 is a software license package for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens SIMATIC panels and PC-based systems. It is designed to work within the SIMATIC automation framework and integrates tightly with Siemens S7 PLC families.

    WinCC flexible 2007 offers a scalable engineering environment supporting a wide range of SIMATIC HMI devices, from Micro Panels to Multi Panels and PC-based systems. The software supports multiple communication protocols including PROFIBUS, PROFINET, MPI, and PPI, enabling connectivity to SIMATIC S7-200, S7-300, S7-400, and other compatible controllers. It includes features such as tag management, alarm logging, trend displays, recipe management, and multi-language project support, with a project migration tool for upgrading from earlier ProTool or WinCC flexible versions.

    WinCC flexible 2007 is widely used in manufacturing automation, process control, and machine building applications across industries such as automotive, food and beverage, pharmaceuticals, and packaging. Its scalable licensing model allows engineers to develop projects for small standalone machines as well as complex multi-panel installations. The software's compatibility with the broader Siemens TIA (Totally Integrated Automation) ecosystem makes it a practical choice for facilities already operating Siemens PLC and drive infrastructure.

    Technical Specifications

    Software Version WinCC flexible 2007
    License Type Full software license package
    Compatible HMI Devices SIMATIC Micro Panels, OP/TP 170, 177, 270, 277, 370, 377, MP 270, MP 370, MP 377, PC-based systems
    Compatible Controllers SIMATIC S7-200, S7-300, S7-400, S7-1200 (limited), LOGO!
    Communication Protocols PROFIBUS, PROFINET, MPI, PPI, Ethernet
    Operating System Windows XP (SP2 or later), Windows Vista, Windows 7
    Project Migration Supports migration from ProTool and earlier WinCC flexible versions
    Language Support Multi-language project configuration
    Series/Product Family SIMATIC WinCC flexible
    Certifications CE

    Common Error Codes and System Events

    Event ID: 1000
    Runtime startup error — WinCC flexible Runtime failed to initialize correctly on the target device.
    Check that the correct Runtime version is installed on the HMI device and that the project was compiled without errors before transfer.
    Event ID: 2501
    Communication connection to PLC lost — the HMI cannot establish or maintain a connection to the configured controller.
    Verify PLC is powered and running, check physical cable connections, confirm correct communication parameters (address, baud rate, protocol) in the project settings.
    Event ID: 3010
    Tag read/write error — a configured tag could not be read from or written to the PLC.
    Check that the tag address exists in the PLC program, verify data type compatibility, and confirm the PLC is in RUN mode.
    Event ID: 4000
    Recipe data error — recipe records could not be read or written correctly.
    Verify recipe configuration in the project, check available storage memory on the HMI device, and ensure the recipe data format matches the PLC tag definitions.
    Event ID: 5100
    Alarm logging buffer overflow — the alarm buffer on the HMI device is full.
    Archive or clear existing alarm logs, increase the configured alarm buffer size in the project settings, and transfer the updated project to the device.
    Event ID: 6200
    Project transfer error — project download to the HMI device failed or was interrupted.
    Check the transfer cable or network connection, ensure the HMI device is in Transfer mode, and verify that the WinCC flexible version on the PC matches the Runtime version on the device.
    Event ID: 7300
    License error — no valid license found for WinCC flexible Runtime or Engineering software.
    Verify the license dongle is connected or the software license is correctly activated using the Siemens Automation License Manager (ALM).

    Frequently Asked Questions

    Which SIMATIC HMI panels are supported by WinCC flexible 2007?

    WinCC flexible 2007 supports a wide range of SIMATIC HMI devices including Micro Panels, OP/TP 170, 177, 270, 277, 370, 377 series panels, Multi Panels (MP 270, MP 370, MP 377), and PC-based Runtime systems.

    Can WinCC flexible 2007 projects be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible projects, though some manual rework may be required depending on the complexity of the project and the target TIA Portal version.

    What operating systems are compatible with WinCC flexible 2007 Engineering software?

    WinCC flexible 2007 Engineering is compatible with Windows XP (SP2 or later), Windows Vista, and Windows 7. It is not officially supported on Windows 10 or later without compatibility workarounds.

    Does WinCC flexible 2007 support PROFINET communication?

    Yes, WinCC flexible 2007 supports PROFINET as well as PROFIBUS, MPI, PPI, and standard Ethernet communication, depending on the HMI hardware and controller being used.

    Is a hardware dongle required to run WinCC flexible 2007?

    WinCC flexible 2007 requires a valid Siemens license managed through the Automation License Manager (ALM). Depending on the license package, this may be a USB dongle-based or soft license.

    Troubleshooting

    WinCC flexible Engineering software fails to install or crashes on startup

    Check the Windows version compatibility and verify that all required Microsoft .NET Framework and Visual C++ redistributable components are installed. Review the installation log for specific error messages.

    Ensure the PC meets the minimum system requirements, install all Windows updates and required prerequisites, and run the installer with administrator privileges. Disable antivirus software temporarily during installation if necessary.

    Project cannot be transferred to the HMI panel

    Verify the HMI device is set to Transfer mode and that the correct communication interface (USB, Ethernet, or MPI/PROFIBUS) is selected in the WinCC flexible Transfer settings. Check cable connections and firewall settings.

    Switch the HMI panel to Transfer mode manually or via the Control Panel on the device. Confirm IP address or MPI address settings match between the engineering PC and the HMI. Disable Windows Firewall temporarily to rule out network blocking.

    Runtime on HMI panel shows 'No connection to PLC' or communication alarms are constantly active

    Check the physical communication cable between the HMI and PLC, verify PLC is powered and in RUN mode, and confirm that the communication parameters in the WinCC flexible project match the PLC configuration.

    Correct any mismatched MPI/PROFIBUS addresses or Ethernet IP settings, replace faulty communication cables, and re-download the project after verifying all connection parameters in the project's 'Connections' editor.

    Alarm or event logs are not being recorded on the HMI device

    Check the alarm logging configuration in the project, verify that sufficient storage memory is available on the HMI device, and confirm that the data medium (internal flash or memory card) is correctly configured as the log destination.

    Increase the allocated log buffer size in the project settings, insert or format a compatible memory card if internal storage is insufficient, and re-transfer the updated project to the HMI device.

    License error message appears when opening WinCC flexible Engineering or starting Runtime

    Open the Siemens Automation License Manager (ALM) and check whether a valid license for WinCC flexible 2007 is present and not expired or corrupted.

    Reconnect the USB license dongle if used, or use ALM to repair or transfer the software license. Contact Siemens license support if the license appears valid but the error persists.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart