• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BS08-0AX0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2BS08-0AX0 WinCC flexible 2008

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6381-2BS08-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BS08-0AX0 is a software license for WinCC flexible 2008 Standard, part of Siemens' WinCC flexible engineering software family. This product provides a PC-based SCADA and HMI configuration environment used to create, commission, and maintain visualization projects for Siemens HMI panels and operator interfaces. It is a full engineering package designed for medium to large-scale HMI projects requiring advanced functionality.

    WinCC flexible 2008 Standard supports configuration of the full range of Siemens HMI devices, including the OP, TP, MP, and Mobile Panel series. The software offers an integrated tag management system, alarm logging, trend displays, recipe management, and report generation. It communicates with Siemens S7-200, S7-300, S7-400, and WinAC controllers via MPI, PROFIBUS, and Industrial Ethernet interfaces, and supports simulation of HMI projects directly on the engineering PC without requiring physical hardware.

    This software is widely used in manufacturing, process automation, food and beverage, automotive, and water treatment industries where Siemens HMI panels are deployed. It is suited for system integrators and OEMs who need to develop and maintain visualization solutions across multiple machine types. The Standard edition supports projects with up to 2048 process tags and is appropriate for complex multi-panel installations.

    Technical Specifications

    Software Version WinCC flexible 2008
    Edition Standard
    Supported HMI Devices OP, TP, MP, Mobile Panel series (Siemens)
    Supported Controllers S7-200, S7-300, S7-400, WinAC
    Communication Interfaces MPI, PROFIBUS, Industrial Ethernet
    Maximum Process Tags 2048
    Operating System Windows XP (SP2 or later), Windows Vista, Windows 7
    Project Simulation Integrated PC-based simulation supported
    Languages Supported Multi-language project configuration
    License Type Single-user software license
    Series WinCC flexible
    Certifications CE

    Common Error Codes & System Events

    Error 1920
    License not found or license server unreachable during software startup
    Verify that the license key (dongle or software license) is correctly installed. Use Siemens Automation License Manager (ALM) to check license status and transfer if necessary.
    Error 1603
    Installation failure during WinCC flexible setup
    Check that the operating system meets minimum requirements. Disable antivirus software during installation and ensure the Windows Installer service is running.
    Compiler Error C01
    Project compilation failed due to inconsistent tag configuration
    Review the tag table for duplicate or invalid tag names. Correct any type mismatches between controller data blocks and HMI tags, then recompile the project.
    Communication Error
    No connection established between WinCC flexible runtime and the PLC
    Verify the communication interface settings (MPI address, PROFIBUS baud rate, or Ethernet IP address). Check physical cabling and ensure the PLC is in RUN mode.
    Transfer Error
    Project transfer to HMI panel failed or was interrupted
    Confirm the HMI panel is in Transfer mode. Check the transfer channel settings in WinCC flexible match the panel's configured interface. Retry the transfer after power-cycling the panel.
    Simulation Runtime Error
    Simulation crashes or fails to start on the engineering PC
    Ensure all required WinCC flexible runtime components are installed. Check for conflicts with other SCADA software and verify that the PC meets the minimum RAM and CPU requirements.
    License Downgrade Warning
    Project was created with a higher edition than the currently licensed edition
    Upgrade the WinCC flexible license to the appropriate edition (Standard or Advanced) or reduce the project scope to match the licensed feature set.

    Frequently Asked Questions

    Which Siemens HMI panels can be configured with WinCC flexible 2008 Standard?

    WinCC flexible 2008 Standard supports the full range of Siemens HMI panels including the OP 77, TP 177, MP 277, MP 377, and Mobile Panel 177 series, among others.

    Is WinCC flexible 2008 compatible with Windows 10?

    WinCC flexible 2008 was designed for Windows XP, Vista, and Windows 7. It is not officially supported on Windows 10; Siemens recommends migrating to TIA Portal WinCC for use on modern operating systems.

    What is the maximum number of process tags supported by the Standard edition?

    The Standard edition of WinCC flexible 2008 supports up to 2048 process tags per project.

    Can WinCC flexible 2008 communicate with S7-1200 or S7-1500 controllers?

    WinCC flexible 2008 has limited or no native support for S7-1200 and S7-1500 controllers; Siemens TIA Portal with WinCC Basic or Advanced is the recommended engineering tool for those controller families.

    Does the 6AV6381-2BS08-0AX0 include a runtime license?

    No, the 6AV6381-2BS08-0AX0 is an engineering software license for project configuration only. Separate runtime licenses are required for PC-based runtime applications.

    Troubleshooting

    WinCC flexible 2008 fails to start and displays a license error

    Open the Siemens Automation License Manager (ALM) and check whether a valid WinCC flexible Standard license is present and not expired or transferred away.

    Use ALM to transfer the license from a USB dongle or license storage medium to the local PC. If the license is missing, contact Siemens or your software supplier to obtain a valid license key.

    Project cannot be transferred to the HMI panel

    Check the transfer settings in WinCC flexible under Transfer > Transfer Settings. Verify the selected interface (Ethernet, USB, or MPI) matches the physical connection and that the panel is set to Transfer mode.

    Set the HMI panel to Transfer mode via its Start Center or loader menu. Correct the IP address or MPI address in the transfer settings and retry. Replace the communication cable if the connection is still not established.

    Compilation errors appear when building the project

    Review the output window for specific compiler messages. Common causes include duplicate tag names, invalid data type assignments, or references to deleted objects.

    Navigate to the flagged tags or screens using the error list, correct the inconsistencies, and recompile. Ensure all external data source connections reference valid PLC data blocks.

    Simulation does not reflect PLC data correctly

    The simulation environment uses internal simulated tags rather than live PLC data. Verify that the simulation tag table is correctly mapped and that no offline default values are overriding runtime values.

    Adjust the simulation tag table to use appropriate test values. For live PLC testing, use the actual transfer and runtime environment on the HMI panel rather than the PC simulation.

    WinCC flexible installation fails partway through setup

    Check the Windows Event Viewer for installation error codes. Common causes include insufficient user privileges, missing Windows Installer prerequisites, or conflicts with previously installed WinCC versions.

    Run the installer as Administrator, uninstall any previous WinCC flexible versions cleanly using the Siemens uninstall tool, and ensure all listed prerequisites (such as .NET Framework and SQL Server components) are installed before retrying.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart