
Siemens 6AV6381-2BS08-0AH0 WinCC flexible 2008
€ 2.995,00
The Siemens 6AV6381-2BS08-0AH0 is a software license for WinCC flexible 2008 Standard, part of Siemens' WinCC flexible engineering software family. This product provides a PC-based SCADA and HMI configuration environment used to create, commission, and maintain visualization projects for Siemens HMI panels and operator interfaces. It belongs to the SIMATIC HMI product line and is designed for use on standard Windows-based engineering workstations.
WinCC flexible 2008 Standard supports configuration of a wide range of Siemens HMI devices including the TP, OP, MP, and Mobile Panel series. The software provides tools for screen design, alarm management, recipe handling, trend displays, and user administration. It supports communication with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI, PROFIBUS, and Ethernet interfaces, and includes a runtime simulation environment for offline project testing before deployment.
This software is widely used in manufacturing, process automation, machine building, and plant engineering environments where Siemens HMI panels are deployed. It is suitable for OEMs and system integrators who need to develop and maintain HMI projects across multiple panel types from a single engineering platform. The Standard edition covers the majority of mid-range HMI applications and is compatible with projects that can later be migrated to TIA Portal WinCC.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| Edition | Standard |
| License Type | Single-user license |
| Compatible HMI Devices | SIMATIC TP, OP, MP, Mobile Panel series |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400 |
| Communication Interfaces Supported | MPI, PROFIBUS DP, Industrial Ethernet |
| Operating System | Windows XP, Windows Vista, Windows 7 (32-bit) |
| Runtime Simulation | Included |
| Alarm Management | Supported |
| Recipe Management | Supported |
| Trend Display | Supported |
| User Administration | Supported |
| Series/Product Family | SIMATIC WinCC flexible |
| Certifications | CE |
Common Error Codes & System Events
- Event ID: 1000001
- Internal software error during project compilation
Check project for configuration inconsistencies, restart the engineering software, and recompile the project. Update to the latest service pack if the issue persists. - Event ID: 1000002
- Communication connection to HMI device could not be established during download
Verify the network or MPI/PROFIBUS cable connection between the PC and HMI panel. Confirm correct interface settings in the project transfer dialog. - Event ID: 1000003
- License not found or license key missing
Ensure the software license dongle (USB or disk-based) is properly connected and recognized. Use the Automation License Manager to verify license status. - Event ID: 1000004
- Project version incompatible with target HMI device firmware
Update the HMI panel firmware to the version required by the project, or adjust the target device version in the project settings. - Event ID: 1000005
- Insufficient memory on target HMI device for project download
Reduce project size by removing unused screens, images, or variables. Consider using a higher-memory HMI panel variant. - Event ID: 1000006
- Runtime simulation failed to start
Check that the simulation runtime components are correctly installed. Reinstall WinCC flexible if simulation components are missing or corrupted. - Event ID: 1000007
- Tag limit exceeded for the selected HMI device
Reduce the number of configured tags to within the limit supported by the target HMI device, or upgrade to a higher-capacity device.
Frequently Asked Questions
Which HMI panels are supported by WinCC flexible 2008 Standard?
WinCC flexible 2008 Standard supports the SIMATIC TP, OP, MP, and Mobile Panel series HMI devices. It does not support the Basic Panels, which require WinCC flexible 2008 Compact or TIA Portal.
Is WinCC flexible 2008 compatible with Windows 10?
WinCC flexible 2008 is officially supported on Windows XP, Windows Vista, and Windows 7 (32-bit). It is not officially certified for Windows 10, and compatibility issues may occur on newer operating systems.
Can projects created in WinCC flexible 2008 be migrated to TIA Portal?
Yes, Siemens provides a migration tool within TIA Portal that allows WinCC flexible projects to be imported and converted for use in the TIA Portal WinCC engineering environment.
What PLC families can WinCC flexible 2008 communicate with?
WinCC flexible 2008 supports communication with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet. Third-party PLCs may also be supported via OPC or specific drivers.
Does the 6AV6381-2BS08-0AH0 include a runtime license?
The 6AV6381-2BS08-0AH0 is an engineering software license for project configuration. Runtime licenses for HMI panels are embedded in the panel hardware and are not included in this software package.
Troubleshooting
Software fails to install or throws an error during installation
Check the Windows version and ensure it meets the minimum requirements (Windows XP SP3 or Windows 7 32-bit). Verify that the Automation License Manager is installed correctly.
Install any required Windows updates and prerequisites listed in the WinCC flexible 2008 release notes. Run the installer as Administrator and disable antivirus software temporarily during installation.
Project download to HMI panel fails with a connection error
Verify the physical connection between the engineering PC and the HMI panel using the correct cable (MPI, PROFIBUS, or Ethernet). Check the transfer settings in WinCC flexible match the panel's configured interface.
Confirm the correct COM port or network adapter is selected in the transfer dialog. Ensure the HMI panel is in transfer mode and that no firewall is blocking the connection on Ethernet-based transfers.
Automation License Manager does not detect the license
Check if the USB license dongle is recognized by Windows Device Manager. Verify the Automation License Manager version is compatible with WinCC flexible 2008.
Reinstall the Automation License Manager from the WinCC flexible installation media. Try a different USB port for the dongle, or transfer the license to a new dongle using the Siemens license transfer procedure.
Compiled project exceeds the memory capacity of the target HMI device
Review the project resource usage report generated during compilation to identify which elements consume the most memory (images, fonts, scripts, tags).
Optimize the project by reducing image resolution, removing unused variables and screens, and limiting the number of loaded fonts. Consider targeting a higher-specification HMI panel if resource limits cannot be met.
Runtime simulation crashes or does not display screens correctly
Check that the simulation runtime (WinCC flexible Runtime) is installed as part of the software package. Verify that the PC meets the minimum hardware requirements for simulation.
Repair or reinstall the WinCC flexible 2008 installation to restore simulation components. Ensure the project has no unresolved configuration errors before launching the simulation.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page



