• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BS07-5AV0 SIMATIC WinCC flexible
    Awaiting product image

    Siemens 6AV6381-2BS07-5AV0 SIMATIC WinCC flexible

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6381-2BS07-5AV0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BS07-5AV0 is a software license for SIMATIC WinCC flexible 2007 Standard, part of Siemens' WinCC flexible engineering software family. This product provides a PC-based HMI configuration and engineering environment used to create, configure, and manage visualization projects for Siemens SIMATIC HMI panels and operator interfaces. It belongs to the WinCC flexible generation, which serves as the predecessor to the current WinCC TIA Portal engineering framework.

    WinCC flexible 2007 Standard edition supports engineering for a wide range of SIMATIC HMI devices including the OP, TP, MP, and Mobile Panel series. The software provides tools for screen design, tag management, alarm configuration, recipe handling, and trend displays. It supports communication via PROFIBUS, MPI, and Ethernet interfaces to Siemens S7-300 and S7-400 PLCs, as well as third-party controllers via standard drivers. The Standard edition offers an expanded project scope compared to the Compact edition, supporting larger panel types and more complex project structures.

    This software is used across a broad range of industrial automation applications including machine building, process automation, and factory floor visualization. It is particularly suited for integrating with Siemens S7 PLC families in manufacturing, packaging, automotive, and food and beverage industries. Engineers and OEMs use WinCC flexible Standard to develop HMI applications for standalone machines as well as networked multi-panel installations.

    Technical Specifications

    Software Edition Standard
    Software Version WinCC flexible 2007
    License Type Single license
    Compatible HMI Devices SIMATIC OP, TP, MP, Mobile Panel series
    PLC Compatibility SIMATIC S7-300, S7-400, S7-200
    Communication Interfaces Supported PROFIBUS, MPI, Industrial Ethernet
    Operating System Windows XP, Windows Vista (32-bit)
    Series/Product Family SIMATIC WinCC flexible
    Certifications CE
    Language Support Multilingual (project and engineering languages)

    Common Error Codes & System Events

    Error 1000
    License not found or invalid license key detected during software startup
    Verify the license dongle is connected or check the license using the Automation License Manager. Transfer a valid license if missing.
    Error 1001
    Project version mismatch — project was created with a newer or incompatible version of WinCC flexible
    Open the project with the correct version of WinCC flexible or use the migration wizard to convert the project.
    Error 1002
    Communication driver not installed or not found for the configured PLC connection
    Reinstall the communication driver from the WinCC flexible installation media and verify the connection settings in the project.
    Error 1003
    Compilation error during project build — invalid tag reference or missing screen object
    Review the compiler output log, correct invalid tag references or missing objects, and recompile the project.
    Error 1004
    Transfer to HMI panel failed — connection to target device could not be established
    Check the physical connection (MPI, PROFIBUS, or Ethernet cable), verify IP or bus address settings, and ensure the panel is in transfer mode.
    Error 1005
    Automation License Manager reports license is in use on another machine
    Release the license from the other machine using the Automation License Manager or use a roaming license if available.
    Error 1006
    Runtime simulation failed to start on the engineering PC
    Verify that all required WinCC flexible runtime components are installed and that no firewall or antivirus software is blocking the simulation process.

    Frequently Asked Questions

    Which HMI panels are supported by WinCC flexible 2007 Standard?

    WinCC flexible 2007 Standard supports a wide range of SIMATIC HMI panels including the TP, OP, MP, and Mobile Panel series. It does not support the newer Comfort Panel series, which requires WinCC TIA Portal.

    Is WinCC flexible 2007 compatible with Windows 10?

    WinCC flexible 2007 is not officially supported on Windows 10. It was designed for Windows XP and Windows Vista (32-bit). Running it on newer operating systems may cause compatibility issues and is not recommended by Siemens.

    Can WinCC flexible 2007 Standard communicate with third-party PLCs?

    Yes, WinCC flexible supports communication with third-party controllers through available communication drivers, including Modbus and other standard protocols, in addition to native Siemens S7 connections.

    What is the difference between WinCC flexible Compact and Standard editions?

    The Standard edition supports a larger number of HMI device types and more complex project configurations compared to the Compact edition. Standard also provides additional features such as more tag capacity and support for larger panel families.

    Does this license include the WinCC flexible Runtime software?

    The 6AV6381-2BS07-5AV0 is an engineering software license for project configuration. Runtime licenses for PC-based visualization are separate products and must be purchased independently if a PC runtime is required.

    Troubleshooting

    Software fails to start and reports a missing or invalid license

    Check whether the USB license dongle is connected or whether a software-based license is present. Open the Automation License Manager to inspect license status.

    Insert the correct USB dongle or transfer a valid WinCC flexible Standard license using the Automation License Manager. If the license is corrupted, contact Siemens support for license recovery.

    Project cannot be transferred to the HMI panel

    Verify the physical communication cable is connected correctly (MPI, PROFIBUS, or Ethernet). Check that the panel is set to transfer mode and that the address settings in the project match the panel configuration.

    Correct any address mismatches, ensure the panel is in transfer mode (hold the touch screen during boot if necessary), and retry the transfer. Replace the communication cable if a hardware fault is suspected.

    Compilation errors appear when building the project

    Review the compiler output window for specific error messages referencing invalid tags, missing screens, or unsupported functions. Identify which objects or tags are flagged.

    Correct all invalid tag references, remove or replace unsupported objects, and ensure all referenced screens exist. Recompile the project after each correction to confirm resolution.

    WinCC flexible installation fails or is incomplete on the engineering PC

    Check the Windows event log and the installation log files for specific error messages. Verify that the PC meets the minimum system requirements and that no conflicting software is installed.

    Uninstall any previous or conflicting versions of WinCC flexible, ensure the operating system is Windows XP or Vista 32-bit, and reinstall using the original installation media with administrator privileges.

    Runtime simulation on the PC does not reflect the latest project changes

    Confirm that the project was saved and fully compiled before starting the simulation. Check whether the simulation is loading a cached or older compiled version.

    Save and recompile the project completely, then restart the simulation. Clear any temporary simulation files if the issue persists.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart