
Siemens 6AV6381-2BT08-0AV0 WinCC flexible 2008
€ 3.495,00
The Siemens 6AV6381-2BT08-0AV0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for a wide range of Siemens operator panels.
WinCC flexible 2008 offers a comprehensive engineering environment with support for multiple HMI device families including SIMATIC Panels, Multi Panels, and PC-based runtime systems. The software supports a variety of communication drivers enabling connectivity to SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs, as well as third-party controllers via standard protocols such as PROFIBUS, PROFINET, MPI, and OPC. It includes features such as faceplates, scripting via VBScript, alarm management, trend displays, recipe management, and multi-language project support. The software is designed for use on Windows-based engineering stations.
WinCC flexible 2008 is widely used in manufacturing, process automation, machine building, and plant engineering applications. It is suitable for configuring operator interfaces on packaging machines, conveyor systems, press lines, and process control installations. The software's scalability allows it to serve both small standalone machine HMI projects and larger distributed visualization systems within industrial plants.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| Software Type | Engineering Software / HMI Configuration Tool |
| Supported HMI Devices | SIMATIC Panels, Multi Panels, Mobile Panels, PC Runtime |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400, S7-1200, third-party via OPC |
| Communication Protocols | PROFIBUS, PROFINET, MPI, OPC, Ethernet |
| Scripting Support | VBScript |
| Operating System | Windows XP, Windows Vista, Windows 7 (32/64-bit) |
| License Type | Single-user software license |
| Language Support | Multi-language project configuration |
| Series/Product Family | SIMATIC WinCC flexible |
| Certifications | CE |
Common Error Codes & System Events
- Event ID: 1000000
- General runtime error indicating an unhandled exception in the WinCC flexible runtime environment.
Restart the runtime application. Check the Windows event log for additional details and ensure all required runtime components are correctly installed. - Event ID: 1000003
- Communication connection to the PLC could not be established or was interrupted.
Verify PLC is powered and online. Check communication cable connections and network settings. Confirm the correct communication driver and PLC address are configured in the project. - Event ID: 1000006
- Tag read/write error — a process tag could not be read from or written to the connected controller.
Check PLC program to ensure the tag address exists and is accessible. Verify data type consistency between HMI tag configuration and PLC variable. - Event ID: 1000010
- License not found or invalid license detected for WinCC flexible runtime or engineering software.
Verify the software license dongle (USB) is connected or the license is correctly installed. Use the Siemens Automation License Manager (ALM) to check license status and transfer if necessary. - Event ID: 1000020
- Project download failed — the project could not be transferred to the target HMI device.
Check the transfer connection (USB, Ethernet, or MPI). Ensure the target device is in transfer mode and that the project is compatible with the target device type and firmware version. - Event ID: 1000030
- Alarm buffer overflow — the alarm log has exceeded its configured storage capacity.
Increase the alarm buffer size in the project settings or archive alarms to an external database. Clear the alarm log on the target device. - Event ID: 1000040
- Recipe data error — recipe records could not be read or written correctly.
Check recipe configuration for correct data types and tag assignments. Verify sufficient storage space on the target device for recipe data files. - Event ID: 1000050
- Script execution error — a VBScript function encountered a runtime error during execution.
Review the VBScript code for syntax or logic errors. Use the WinCC flexible output window during simulation to identify the specific line causing the fault.
Frequently Asked Questions
Which Siemens PLC families are compatible with WinCC flexible 2008?
WinCC flexible 2008 supports SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs. Third-party controllers can also be integrated via OPC or specific communication drivers.
What HMI panel types can be configured with this software?
The software supports the full range of SIMATIC HMI panels including Basic Panels, Comfort Panels (earlier generations), Multi Panels, Mobile Panels, and PC-based WinCC flexible Runtime systems.
Is a hardware dongle required to run WinCC flexible 2008?
Yes, WinCC flexible 2008 requires a valid license managed through the Siemens Automation License Manager (ALM). Depending on the license variant, this may be tied to a USB dongle or a software-based license key.
What operating systems are supported for the engineering station?
WinCC flexible 2008 is compatible with Windows XP, Windows Vista, and Windows 7 in both 32-bit and 64-bit editions, depending on the specific service pack and system requirements.
Can WinCC flexible 2008 projects be migrated to TIA Portal?
Yes, Siemens provides a migration tool within TIA Portal that allows WinCC flexible 2008 projects to be imported and converted, though some manual rework may be required depending on the project complexity.
Troubleshooting
Software installation fails or aborts partway through
Check Windows event logs and the Siemens setup log files for specific error codes. Verify that the PC meets minimum hardware and OS requirements and that no conflicting Siemens software versions are installed.
Uninstall any conflicting or older versions of WinCC flexible using the Siemens Automation Software Uninstaller. Ensure .NET Framework and other prerequisites are installed, then re-run the installation as Administrator.
Runtime license error displayed on startup — software runs in demo mode
Open the Siemens Automation License Manager (ALM) and check whether a valid license for WinCC flexible 2008 is present and assigned to this computer.
Connect the USB license dongle if applicable, or use ALM to transfer the license from another storage location. If the license is missing, contact Siemens license support for recovery options.
HMI project cannot be downloaded to the target panel
Verify the transfer connection type (USB, Ethernet, or MPI) and confirm the panel is set to transfer mode. Check that the project's target device type and firmware version match the physical panel.
Switch the panel to transfer mode via the Start Center. Ensure the correct interface is selected in the transfer settings within WinCC flexible. Update panel firmware if there is a version mismatch.
Communication to PLC is lost intermittently during runtime
Check physical cable connections and network infrastructure for faults. Review the WinCC flexible diagnostics view for communication error messages and note the frequency and pattern of disconnections.
Replace suspect cables or connectors. Verify PLC communication settings match the HMI project configuration. Check for IP address conflicts on Ethernet networks and ensure PROFIBUS termination resistors are correctly installed where applicable.
Simulation of project on PC does not reflect correct tag values
Confirm that the simulation is using the correct PLC connection or that a PLC simulator (such as S7-PLCSIM) is running and configured with matching tag addresses.
Start S7-PLCSIM and load the corresponding PLC program before launching WinCC flexible simulation. Verify that tag addresses in the HMI project exactly match the variable addresses in the PLC program.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page



