• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BN08-0AX0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2BN08-0AX0 WinCC flexible 2008

    € 2.495,00

    Reset
    Clear
    SKU: 6AV6381-2BN08-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BN08-0AX0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across the SIMATIC HMI range.

    WinCC flexible 2008 offers a scalable engineering environment supporting a wide range of SIMATIC HMI devices, from Micro Panels to Multi Panels and PC-based systems. The software includes features such as faceplates, scripts (VBScript), alarm management, trend displays, recipe management, and user administration. It supports communication via PROFIBUS, PROFINET, MPI, and Ethernet interfaces, and is compatible with SIMATIC S7-200, S7-300, S7-400, and S7-1200 controllers. The software runs on standard Windows operating systems and provides a project migration path from earlier ProTool and WinCC flexible versions.

    WinCC flexible 2008 is widely used in manufacturing, process automation, machine building, and plant engineering applications. It is suitable for industries such as automotive, food and beverage, pharmaceuticals, and water treatment, where reliable HMI visualization and operator control are required. The software's scalability makes it applicable to both small standalone machine panels and larger distributed SCADA-type installations.

    Technical Specifications

    Software Version WinCC flexible 2008
    Product Family SIMATIC WinCC flexible
    License Type Engineering Software License
    Supported HMI Devices SIMATIC Micro Panels, Mobile Panels, Operator Panels, Multi Panels, PC-based HMI
    Communication Interfaces PROFIBUS, PROFINET, MPI, Ethernet
    Compatible Controllers SIMATIC S7-200, S7-300, S7-400, S7-1200
    Scripting Support VBScript
    Operating System Windows XP, Windows Vista, Windows 7 (32-bit)
    Alarm Management Included
    Recipe Management Included
    Trend Display Included
    User Administration Included
    Migration Support ProTool, WinCC flexible 2004/2005/2007
    Certifications CE

    Common Error Codes & System Events

    Event ID: 1000
    Application error during WinCC flexible runtime startup, typically caused by a corrupted project file or incompatible runtime version.
    Reinstall the WinCC flexible runtime software and verify that the project file is compatible with the installed software version.
    Event ID: 1001
    License not found or license key missing for WinCC flexible engineering software.
    Insert the valid license key using the Siemens Automation License Manager (ALM) and verify the license is correctly assigned to the installation.
    Event ID: 1002
    Communication error between HMI panel and PLC controller; connection cannot be established.
    Check the communication cable and interface settings. Verify the PLC address, baud rate, and communication protocol settings in the project configuration.
    Event ID: 1003
    Project transfer failed between engineering PC and target HMI device.
    Verify the transfer settings, ensure the target device is in transfer mode, and check the network or serial connection between the PC and the HMI panel.
    Event ID: 1004
    Runtime project file is incompatible with the installed WinCC flexible runtime version on the target panel.
    Recompile the project using the correct WinCC flexible version matching the target panel's runtime version, then retransfer the project.
    Event ID: 1005
    Insufficient memory on the target HMI device to load the project.
    Reduce the project size by optimizing graphics, reducing the number of screens or variables, or use a target device with greater memory capacity.
    Event ID: 1006
    Tag or variable limit exceeded for the configured WinCC flexible license edition.
    Upgrade the WinCC flexible license to a higher edition that supports a greater number of tags, or reduce the number of configured variables in the project.

    Frequently Asked Questions

    Which SIMATIC HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports a wide range of SIMATIC HMI devices including Micro Panels (KP, TP series), Mobile Panels, Operator Panels (OP series), Multi Panels (MP series), and PC-based HMI systems running WinCC flexible Runtime.

    Which PLC families are compatible with WinCC flexible 2008?

    WinCC flexible 2008 is compatible with SIMATIC S7-200, S7-300, S7-400, and S7-1200 controllers, as well as SIMATIC 505 and third-party controllers via OPC communication.

    Can WinCC flexible 2008 projects be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that allows WinCC flexible 2008 projects to be imported and converted, though some manual rework may be required depending on the complexity of the project.

    What operating systems are supported for running WinCC flexible 2008 engineering software?

    WinCC flexible 2008 engineering software is supported on Windows XP (SP3), Windows Vista, and Windows 7 (32-bit). It is not natively supported on 64-bit operating systems without compatibility measures.

    Is a hardware dongle required to run WinCC flexible 2008?

    WinCC flexible 2008 uses Siemens' Automation License Manager (ALM) for license management. The license can be stored on a USB dongle or transferred to the hard drive of the engineering PC.

    Troubleshooting

    WinCC flexible 2008 engineering software fails to start after installation

    Check the Windows Event Viewer for application errors. Verify that the Automation License Manager (ALM) is installed and a valid license is present. Confirm the operating system version is compatible.

    Reinstall the Automation License Manager and ensure the correct license for WinCC flexible 2008 is assigned. If the OS is 64-bit, apply the appropriate compatibility settings or use a supported 32-bit environment.

    Project cannot be transferred to the HMI panel

    Verify that the HMI panel is in transfer mode and that the correct transfer channel (Ethernet, USB, or serial) is selected in the transfer settings. Check for firewall or antivirus software blocking the connection.

    Set the HMI panel to transfer mode via its Start Center, disable any firewall rules blocking the transfer port, and confirm the IP address or COM port settings match those configured in the WinCC flexible project.

    Runtime communication to PLC is lost intermittently

    Check the physical communication cable and connectors for damage. Review the configured polling cycle times and the number of active tags. Verify PLC CPU load and communication buffer settings.

    Replace damaged cables, reduce the number of simultaneously active tags, increase the update cycle time for non-critical variables, and ensure the PLC communication module is not overloaded.

    Alarm messages are not displayed correctly or are missing in runtime

    Check the alarm configuration in the WinCC flexible project, including the trigger tags, alarm classes, and display settings. Verify that the alarm view object is correctly configured on the relevant screens.

    Recheck the alarm tag connections and ensure the correct alarm class is assigned. Recompile and retransfer the project to the HMI panel after making corrections.

    WinCC flexible 2008 reports a license error after a Windows update or PC hardware change

    A hardware change or Windows update can invalidate a hard-drive-bound license. Open the Automation License Manager to check the license status and identify if the license is shown as defective or missing.

    Use the Siemens Automation License Manager to repair or re-transfer the license. If the license is stored on a USB dongle, re-insert the dongle. Contact Siemens support if the license cannot be recovered.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart